24
Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and
follow the steps listed. If further assistance is needed, please see the back cover of this manual.
PROBLEM: The power does not turn on
SOLUTION:
a. Make sure that the power cord is fully plugged into the treadmill. In addition, make sure that the
power cord is plugged into a surge suppressor, and that the surge suppressor is plugged into a
properly grounded outlet (see page 9). Use only a single-outlet surge suppressor that meets all
the specifications described on page 9.
IMPORTANT: The treadmill is not compatible with
GFCI-equipped outlets.
b. Make sure that the key is inserted into the console.
c. Check the circuit breaker located on the treadmill
frame near the power cord. If the switch protrudes as
shown, the circuit breaker has tripped. To reset the
circuit breaker, wait for five minutes and then press
the switch back in.
d. Check the on/off switch located on the treadmill
frame near the power cord. The switch must be in the
“on” position.
PROBLEM: The power turns off during use
SOLUTION:
a. Check the circuit breaker located on the treadmill frame near the power cord (see c. above). If the
circuit breaker has tripped, wait for five minutes and then press the switch back in.
b. Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for
five minutes, and then plug it back in.
c. Remove the key from the console. Reinsert the key into the console.
d. Make sure that the on/off switch is in the “on” position.
e. If the treadmill still will not run, please see the back cover of this manual.
PROBLEM: The chest pulse sensor does not function properly
SOLUTION:
a. If the chest pulse sensor does not function properly, see CHEST PULSE SENSOR TROU-
BLESHOOTING on page 8.
b. If the chest pulse sensor still does not function
properly, the battery should be replaced. To re-
place the battery, locate the battery cover on the
back of the sensor unit. Insert a coin into the slot
in the cover and turn the cover counterclockwise
to the “open” position. Then, remove the cover.
Next, remove the old battery from the sensor
unit. Insert a new
CR 2032 battery,
making sure
that the writing is on top. In addition, make sure
that the rubber gasket is in place in the sensor
unit. Then, reattach the battery cover and turn it
to the closed position.
TROUBLESHOOTING
Tripped
c
Reset
On
Position
d
CR2032
Battery
Cover
Rubber
Gasket
b