Input port
Output port
Output port
6S LiPo 16000mAh
Task Settings and Notes
Operation and Setup
External Discharge Functions
The external discharge function uses an external high-power load resistor to quickly
discharge the battery in an accurate way. When using it, the battery to be discharged needs
to be connected to the input port, and the output is connected to the resister load. It is
recommended that the resistance of the load be between 1.5 and 2.5 ohms. Other resistance
values can also be used normally, but may not be able to operate at full power. While the
external discharge is running, the load is very hot, please pay attention to safety and avoid
accidents or personal injury.
Storage Function
When the storage function is selected and if the battery is lower than the preset storage voltage, the
charging task will be automatically performed; if the battery voltage is higher than the preset storage
voltage, the discharge task will be automatically performed. In order to save the task time, the storage
and discharge tasks do not accurately balance the cell voltage. There may have some error between the
cell voltage and the preset value at the end of the task, which is a normal phenomenon.
Balance Function
The balance function is used to balance the voltage of batteries and make them equal. The balance time
is related to the battery voltage difference and the target voltage. When the menu is switched to the
balance mode, the charger automatically analyzes and sets the initial balance voltage value, and the
user can freely adjust it. The charger's charging ability is much larger than the discharge capacity; in the
balance operation , selecting voltage equal or larger than the current battery voltage usually lets user
attain faster effect in balancing.