52
7) Pour the cleaning solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to overflow into the drain pan.
Note: If there is excess scale on the extruding head, fill the evaporator assembly and
reservoir as described above, then use a clamp on the reservoir hose between
the reservoir and evaporator assembly to block flow. Pour additional cleaning
solution over the extruding head until the evaporator assembly is completely full.
8) Replace the spout and strap in their correct positions.
9) Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp on
the reservoir hose in step 7, remove it before operation.
10) In bad or severe water conditions, clean the float switch assembly as described below.
Otherwise, continue to step 11.
a. Remove the float switch assembly from the reservoir cover.
b. Wipe down the float switch assembly with the cleaning solution.
c. Rinse the float switch assembly thoroughly with clean water.
d. Replace the float switch assembly in its correct position.
Reservoir
Reservoir Cover
Float Switch Assembly
Fig. 10
5) Remove all of the ice from the dispenser unit/storage bin.
6) Remove the strap connecting the spout to the chute assembly, then remove the spout.
See Fig. 9.
Fig. 9
Strap
Spout
Chute
Rubber O-Ring
Packing
Proximity Switch
Packing
Ties
(Hook and Loop)
Chute Insulation
Baffle
Plate
Packing
Backup Bin Control Assembly Mount
Actuator
Shaft
Extruding Head
Evaporator Assembly
Nylon O-Ring
Reservoir
Chute
Bracket
Infrared Sensor Lens
Float Switch
Assembly
Reservoir Cover
Reservoir
Hose