25
C. Performance Data
1. FS-1022MLH-C with SRC-10H
Note: We reserve the right to make changes in specifications and design without prior
notice.
APPROXIMATE
Ambient
Water Temp. (F)
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
*832
378
803
365
784
356
80
765
347
747
340
729
331
90
712
324
*703
320
679
309
lbs./DAY ( l/day)
100
663
301
647
294
*600
273
APPROXIMATE ELECTRIC
70
1713
--
1717
--
1722
--
CONSUMPTION
80
1727
--
1731
--
1736
--
90
1740
--
1745
--
1760
--
watts
100
1775
--
1789
--
1804
--
APPROXIMATE WATER
70
*100
377
96
364
94
356
CONSUMPTION PER 24 HR.
80
92
347
90
339
88
331
90
85
323
*84
319
81
308
gal. / day (l/day)
100
80
301
78
293
*72
272
EVAPORATOR OUTLET TEMP.
70
*14
-10
14
-10
14
-10
F ( C)
80
14
-10
16
-9
16
-9
90
16
-9
*16
-9
18
-8
100
18
-8
18
-8
*18
-8
HEAD PRESSURE
70
*224
15.7
224
15.7
224
15.7
80
233
16.4
233
16.4
233
16.4
90
242
17.0
*242
17.0
242
17.0
PSIG (kg/sq.cmG)
100
279
19.6
279
19.6
*279
19.6
SUCTION PRESSURE
70
*29
2.0
29
2.0
29
2.0
PSIG (kg/sq.cmG)
80
30
2.1
30
2.1
30
2.1
90
31
2.2
*31
2.2
31
2.2
100
33
2.3
33
2.3
*33
2.3
50
70
90
HEAT OF REJECTION FROM BODY
1130 BTU/hr AT 90 F/WT 70 F