44
8) Pour the cleaning solution into the water tank.
9) Fully open the cleaning valve on the left side wall of the machine compartment.
10) Move the control switch to the "WASH" position. Replace the insulation panel and the
front panel in their correct positions.
11) Turn on the power supply to start the washing process.
12) Turn off the power supply after 30 minutes.
13) Remove the front panel.
14) Remove the insulation panel. Remove cube guide B, then remove cube guide A.
Remove the overflow cap, overflow pipe, and water shield.
15) Remove the drain plug. Allow the water tank to drain, then replace the drain plug in its
correct position.
16) Replace the water shield, overflow pipe, overflow cap, cube guide A, cube guide B, and
insulation panel in their correct positions.
17) Move the control switch to the "ICE" position.
18) Close the cleaning valve.
Note: The icemaker will not operate unless the cleaning valve is completely closed.
19) Replace the front panel in its correct position.
20) Turn on the power supply to fill the water tank with water.
21) Turn off the power supply after 3 minutes.
22) Remove the front panel and fully open the cleaning valve.
23) Move the control switch to the "WASH" position.
24) Replace the front panel in its correct position.
25) Turn on the power supply to rinse off the cleaning solution.
26) Turn off the power supply after 5 minutes.
27) Remove the front panel.
28) Remove the insulation panel. Remove
cube guide B, then remove cube guide A.
Remove the overflow cap, overflow pipe,
and water shield.
29) Remove the drain plug. Allow the water
tank to drain, then replace the drain plug in
its correct position.
30) Replace the water shield, overflow pipe,
overflow cap, cube guide A, cube guide
B, and insulation panel in their correct
positions.
31) Repeat steps 17 through 30 three more
times to rinse thoroughly.
Note: If you do not sanitize the icemaker, go to step 12 in "2. Sanitizing Procedure."
Fig. 6
Overflow Pipe
Cube Guide A
Overflow Cap
Water
Shield
Drain
Plug
Cube Guide B