43
IMPORTANT
1. The cleaning valve is opened during cleaning and sanitizing to allow solution
flow to the inside of the evaporator. It should be closed for all icemaking
operation. The compressor will not operate unless this valve is completely
closed.
2. To close the cleaning valve, the valve handle should be at a right angle to the
valve body. To open the cleaning valve, the valve handle should be parallel to
the valve body.
CLOSED
Normal Icemaking Operation
OPEN
Cleaning and Sanitizing Operation
(allows solution flow to the inside of
the evaporator)
1. Cleaning Procedure
1) Dilute 35 fl. oz. (400 ml) of Hoshizaki "Scale Away" with 2.5 gal. (9.5 l) of warm water.
2) Remove all ice from the evaporator and the dispenser unit/storage bin.
Note: To remove cubes on the evaporator, turn off the power supply and turn it back on
after 3 minutes. The harvest cycle starts and the cubes will be removed from the
evaporator.
3) Turn off the power supply.
4) Remove the front panel. Remove the insulation panel. Remove cube guide B, then
remove cube guide A. See Fig. 6. Remove the overflow cap, overflow pipe, and water
shield.
5) Remove the drain plug. Allow the water tank to drain, then replace the drain plug in its
correct position. Be careful not to cross thread it.
6) Replace the water shield, overflow pipe, overflow cap, cube guide A and cube guide B in
their correct positions. Be careful not to cross thread the overflow pipe.
7) In bad or severe water conditions, clean the float switch as described below. Otherwise,
continue to step 8.
a. Disconnect the vent tube and the flush tube from the top of the float switch housing,
then remove the float switch assembly. Remove the rubber boot from the bottom of
the assembly.
b. Remove the retainer rod from the bottom of the float switch housing, then remove
the float. Be careful not to bend the retainer rod excessively when removing it.
c. Wipe down the float switch housing, shaft, float, and retainer rod with cleaning
solution. Clean the inside of the rubber boot and hose with cleaning solution. Rinse
the parts thoroughly with clean water.
d. Reassemble the float switch assembly and replace it and the rubber boot in their
correct positions. Reconnect the vent tube and the flush tube.