background image

5

8. MAINTENANCE

WARNING

1. Do not splash water directly onto the unit. It may cause short 

circuit, electric shock, corrosion or failure.

2. To prevent electric shock, do not touch the attachment 

plug, power switch (earth leakage circuit breaker), or other 

electrical parts with damp hands.

CAUTION

1. To prevent electric shock or burn, always turn off the power 

switch and unplug the unit before cleaning or inspecting the 

unit.

2. Do not use combustible spray or place volatile and 

flammable  substances  near  the  unit. They  could  catch  fire 

from a spark of a switch or the like.

IMPORTANT

To prevent damage to the painted or plastic surfaces, do not 

use the following: thinner, benzine, alcohol, petroleum, soap 

powder, polishing powder, alkaline cleaner, acid, and scouring 

pad. When using a chemical cloth, follow the instructions of the 

manufacturer.

[a] EXTERIOR

* The exterior is powder painted. Wipe it with warm water or a neutral 

cleaner, if required. Use a damp cloth to wipe off any cleaner.

* The operation panel, salt water tank and water outlets are made of 

plastic. Keep them away from impact or sharp edges.

[b] CLEANING FILTER AND SALT WATER TANK

1) Prepare a plastic bucket. 

Pull out the cap, salt water 

hose and filter from the 

salt water tank, and put 

them into the bucket.

2) Wash the filter attached 

to the salt water hose with 

warm water, and remove 

any dirt or dust to prevent 

the filter from clogging.

3) Wash the salt water tank with a neutral 

cleaner to remove any salt grains or dirt. Rinse 

thoroughly.

4) Wipe dry.

5) To refit the salt water hose, fit the cap on the 

salt  water  tank,  and  insert  the  filter,  then  the 

hose into the hole in the center of the cap. 

Push in the salt water hose until the stopper 

hits the cap.

[c] CLEANING SHOWER NOZZLE

When clogged, remove the shower nozzle as shown 

and use a toothbrush to clean the shower holes.

Note: To prevent damage to the shower nozzle, do 

not use a metal brush or knife.

[d] CHECKING WATER SOFTENER

* Check that water from the water softener is soft.

* Check that there is enough salt for refrigeration in the water softener.

* For other instructions, follow the instruction manual for the water 

softener.

Cap

Salt Water 

Hose

Salt Water 

Tank

Stopper

[e] CLEANING WATER FILTER

Remove and clean the water filter as required.

Drain Valve

Water Supply 

Pipe

Water 

Supply

Pressure Gauge

Shut-off Valve

Water Softener

Water Softener Assembly

Water Filter

Dual Check Valve 

(accessory)

To unit

Pressure Reducing

Valve (accessory)

9. INSPECTION

Use a copy of “14. [a] DAILY INSPECTION SHEET” and “14. [b] 

MONTHLY INSPECTION SHEET” to keep records.

[a] pH, AVAILABLE CHLORINE CONCENTRATION (DAILY)

1) Drain more than 1 liter each of sanitizing water and cleaning water. 

Sample each water from its outlet into separate containers.

2) Use the pH and chlorine test papers to check that each value is 

within the following range.

Water

Test Paper

pH

Available Chlorine

Sanitizing

pH test paper UNIV Acidic range

Chlorine test paper

20 mg/kg (ppm)

or more

Cleaning

pH test paper UNIV

Approx. 11

* It is not necessary to check the available chlorine concentration of 

cleaning water.

Note: See the instruction manual of each test paper for details of its 

proper handling.

 

If any of the checked values exceeds the specified range, 

contact an authorized Hoshizaki service company.

 

If water is not dispensed from its proper outlet, contact an 

authorized Hoshizaki service company.

[b] SALT WATER LEVEL (DAILY)

Check the salt water level according to “3. [a] CHECKING AMOUNT 

OF REMAINING SALT WATER”.

[c] WATER LEAKS (DAILY)

Check the unit and surrounding floor for water leaks. If any is found, 

contact an authorized Hoshizaki service company.

[d] REPLACE CELL LAMP (DAILY)

Check that the replace cell lamp on the operation panel is not flashing. 

The service life of the electrode in the electrolytic cell depends on 

water quality. To maintain effective performance of electrolyzed 

water, the electrolytic cell needs to be replaced every 3000 hours of 

operation.

If  the  replace  cell  lamp  is  flashing,  contact  an  authorized  Hoshizaki 

service company.

Summary of Contents for ROX-10WB3-EW

Page 1: ...ROX 10WB3 EW L1X003115 032017 WATER ELECTROLYZER FOR END USER INSTRUCTION MANUAL 3 16 Minamiyakata Sakae Toyoake Aichi 470 1194 Japan...

Page 2: ...dance with current regulations according to the manufacturer s instructions This electrolyzer is not intended for outdoor use including under canopy Exposure to rain may cause electric leak or shock D...

Page 3: ...cathode Cl Negative ions drawn to anode Salt Water NaCl Diaphragm Electrolytic Cell Flow of electrons Cl H2O H2O Na Na Na Na Na OH OH 2e 2e H2 HOCl Reactions at Anode Chloride ions Cl and hydroxide i...

Page 4: ...r the set dispense time indicated in the display on the control panel adjustable from 1 to 60 minutes c CONTROL PANEL 1 Display lamp red Indicates the item currently displayed on the operation panel 2...

Page 5: ...UP 1 Plug in the unit 2 Open the water supply line shut off valve 3 Check for proper operation of the water softener Refer to the instruction manual provided for operating instructions See 9 f WATER H...

Page 6: ...e d CHECKING WATER SOFTENER Check that water from the water softener is soft Check that there is enough salt for refrigeration in the water softener For other instructions follow the instruction manua...

Page 7: ...mpany Only qualified personnel may repair the unit Do not attempt to repair it yourself e CELL RUN TIME CURRENT VOLTAGE AS REQUIRED To check the cell run time current and voltage 1 Open the control pa...

Page 8: ...ed Contact an authorized Hoshizaki service company E53 Reversing relay defective E61 Flow switching valve defective E84 Float switch defective None E74 Thermistor defective E82 Float switch defective...

Page 9: ...tion Salt water level Neutralizing agent level Water hardness Water leaks around unit Water leaks from water circuit Cell run time Checked by Sanitizing water only Date Time pH Sanitizing water Cleani...

Reviews: