background image

7

[a] OPERATIONAL PROBLEMS

Problem

Possible Cause

Remedy

Abnormal 

noise

Operating sounds 

(water supply, 

pump)

No problem.

Unstable 

installation

Level the unit.

Contact with other 

objects

Keep them away from the unit.

Electrolyzed 

water is not 

available

Power failure

Wait until power is resumed.

Unplugged

Plug in.

Power switch (earth 

leakage circuit 

breaker) is off

Turn it on. If it turns off 

automatically, there is a risk of 

electric leak. Contact an authorized 

Hoshizaki service company.

Operation lamp 

(green) is off

Press the dispense button. See "5. 

START UP".

Electrolyzed 

water is not 

available

Add salt water lamp 

(red) is on

Add salt. See "3. [b] SUPPLYING 

SALT WATER".
Purge the salt water pump. See "4. 

PURGING SALT WATER PUMP".

Wet floor

Water leaks

Contact an authorized Hoshizaki 

service company.

[b] WHEN ERROR LAMP COMES ON

When the error lamp (red) on the operation panel comes on, check 

the error code in the display on the control panel.

Lamp Code Problem Possible Cause

Remedy

Error E11 Inadequate 

water 

supply

Water failure

Restart the unit after water 

supply is resumed. See "7. 

WATER FAILURE".

Water supply 

valve is closed

Open.

* After the problem is resolved, press the dispense button on the 

operation panel. The error lamp goes off. Press the dispense button 

again to resume operation.

When one of the following error codes appears, immediately contact 

an authorized Hoshizaki service company.

Lamp Code

Problem

Possible Cause Remedy

Error E14 Water valve defective

Repair or replacement is 

required.

Contact an authorized 

Hoshizaki service company.

E53 Reversing relay defective
E61 Flow switching valve 

defective

E84 Float switch defective

None E74 Thermistor defective

E82 Float switch defective

12. WARRANTY

Hoshizaki warrants to the original owner/user that all Hoshizaki 

branded products shall be free of defects in material and/or 

workmanship for the duration of the “warranty period”. The warranty 

shall be effective for one year from the date of installation.

Hoshizaki’s liability under the terms of the warranty are limited and 

shall exclude routine servicing, cleaning, essential maintenance and/

or repairs occasioned by misuse and installations not in accordance 

with Hoshizaki guidelines.

Warranty repairs should be completed by an approved Hoshizaki 

dealer or service agency using genuine Hoshizaki components.

To obtain full details of your warranty and approved service agency, 

please contact:

e-Water Systems Pty Ltd

TEL : 1300 EWATER

FAX : +61(3) 9686 1377

13. SPECIFICATIONS

Model

ROX-10WB3-EW

Electrolysis System

Membrane technology

Electrolyte

Salt containing at least 99% sodium chloride

Power Supply

1 phase 220 - 240V 50/60Hz

Electric Consumption 170W
Performance 

(Standard)

Sanitizing water: pH3 or less, available 

chlorine 20 - 60mg/kg

Cleaning water: pH11 or more

Production Rate 

(Standard)

Sanitizing water: Approx. 1.0L/min

Cleaning water: Approx. 1.0L/min

Safety Device

Earth leakage circuit breaker

Exterior

Galvanized steel (polyester powder paint), 

ABS plastic

Dimensions

Body: 350mm(W) x 174mm(D) x 340mm(H)

Weight

13kg

Temperature Range

Ambient: 5 - 35°C

Water supply: 5 - 30°C

Water Supply

Comply with local water requirements

Pressure: 0.10 - 0.75MPa (with pressure 

reducing valve)

Summary of Contents for ROX-10WB3-EW

Page 1: ...ROX 10WB3 EW L1X003115 032017 WATER ELECTROLYZER FOR END USER INSTRUCTION MANUAL 3 16 Minamiyakata Sakae Toyoake Aichi 470 1194 Japan...

Page 2: ...dance with current regulations according to the manufacturer s instructions This electrolyzer is not intended for outdoor use including under canopy Exposure to rain may cause electric leak or shock D...

Page 3: ...cathode Cl Negative ions drawn to anode Salt Water NaCl Diaphragm Electrolytic Cell Flow of electrons Cl H2O H2O Na Na Na Na Na OH OH 2e 2e H2 HOCl Reactions at Anode Chloride ions Cl and hydroxide i...

Page 4: ...r the set dispense time indicated in the display on the control panel adjustable from 1 to 60 minutes c CONTROL PANEL 1 Display lamp red Indicates the item currently displayed on the operation panel 2...

Page 5: ...UP 1 Plug in the unit 2 Open the water supply line shut off valve 3 Check for proper operation of the water softener Refer to the instruction manual provided for operating instructions See 9 f WATER H...

Page 6: ...e d CHECKING WATER SOFTENER Check that water from the water softener is soft Check that there is enough salt for refrigeration in the water softener For other instructions follow the instruction manua...

Page 7: ...mpany Only qualified personnel may repair the unit Do not attempt to repair it yourself e CELL RUN TIME CURRENT VOLTAGE AS REQUIRED To check the cell run time current and voltage 1 Open the control pa...

Page 8: ...ed Contact an authorized Hoshizaki service company E53 Reversing relay defective E61 Flow switching valve defective E84 Float switch defective None E74 Thermistor defective E82 Float switch defective...

Page 9: ...tion Salt water level Neutralizing agent level Water hardness Water leaks around unit Water leaks from water circuit Cell run time Checked by Sanitizing water only Date Time pH Sanitizing water Cleani...

Reviews: