3
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[b] OPERATION PANEL
[1] Operation lamp (green)
Illuminates while the unit is running.
[2] Ready lamp (green)
Flashes until the desired settings are achieved and stays on while the
unit is ready to dispense proper electrolyzed water.
[3] Add salt water lamp (red)
Illuminates when the salt water tank level is too low. See “11. [a]
OPERATIONAL PROBLEMS”.
[4] Replace cell lamp (red)
Flashes when the electrolytic cell needs to be replaced.
[5] Error lamp (red)
Illuminates when any abnormality is detected. See “11. [b] WHEN
ERROR LAMP COMES ON”.
[6] Reset button
Press this button after the add salt water lamp comes on. See “4.
PURGING SALT WATER PUMP”.
[7] Display
Indicates the cell run time during normal operation, amperage or
voltage by the control panel operation, and error codes in case of
trouble.
[8] Dispense button
Press this button to start or stop dispensing electrolyzed water.
[9] Water outlet lamp
Indicates the type of water to be dispensed from each outlet.
Note: To maintain the desired settings, the unit automatically
alternates the water outlets at regular intervals (every 12 hours
at factory setting). Check the type of water to be dispensed from
each outlet by the water outlet lamp.
The following dispensing modes are available:
Continuous dispensing mode
Activated or disactivated by pressing the dispense button or
putting a hand or object in front of the dispensing sensor.
Portion control dispensing mode
Activated by pressing the dispense button for 3 seconds or
putting a hand or object in front of the dispensing sensor for 3
seconds. Water automatically stops after the set dispense time
indicated in the display on the control panel (adjustable from 1
to 60 minutes).
[c] CONTROL PANEL
[1] Display lamp (red)
Indicates the item currently displayed on the operation panel.
[2] * Button (down button)
When adjusting the settings, press this button to reduce the value.
[3] Set button
Press this button to adjust the settings. Should be used by qualified
service personnel only. See the installation manual for details.
[4] Display select button (up button)
Press this button to select the indication in the display (electrolytic cell
run time, current or voltage). The display lamp illuminates the selected
item.
When adjusting the settings, press this button to raise the value.
[5] Flow rate select button
Adjusts the flow rate.
[6] Flow rate lamp (red)
Indicates the flow rate currently selected.
Note: When the low flow rate is selected, sanitizing water may have
an excessive available chlorine concentration. Select this flow
rate only when the electrolyzed water property is inadequate.
[d] ACCESSORIES
pH test paper UNIV Chlorine test paper Instruction manual
Installation manual Operation sheet
Cap
Elbow
Water supply hose Pressure reducing valve
Salt water tank
Shower nozzle
O-ring [for shower nozzle]
Straight nozzle
Gasket
Nozzle hose [with gasket]
Measuring cup
Wood screw
Screw collar
Rubber dropper
Nipple
Dual check valve
3. CHECKS BEFORE OPERATION
[a] CHECKING AMOUNT OF REMAINING SALT WATER
1) Check that there is enough salt water in the salt water tank.
2) Add salt water according to “[b] SUPPLYING SALT WATER” if there
is not enough or no salt water in the tank.
[b] SUPPLYING SALT WATER
CAUTION
Use sodium chloride (NaCl) or potassium chloride (KCl) of
not less than 99% of purity. Use of any other salt may cause
failure, clogged pipes or health problems.
[1]
[6]
[2]
[3]
[4]
[5]