background image

3

[1]

[2]

[3]

[4]

[5]

[6]

[7]

[8]

[9]

[b] OPERATION PANEL

[1] Operation lamp (green)

Illuminates while the unit is running.

[2] Ready lamp (green)

Flashes until the desired settings are achieved and stays on while the 

unit is ready to dispense proper electrolyzed water.

[3] Add salt water lamp (red)

Illuminates when the salt water tank level is too low. See “11. [a] 

OPERATIONAL PROBLEMS”.

[4] Replace cell lamp (red)

Flashes when the electrolytic cell needs to be replaced.

[5] Error lamp (red)

Illuminates when any abnormality is detected. See “11. [b] WHEN 

ERROR LAMP COMES ON”.

[6] Reset button

Press this button after the add salt water lamp comes on. See “4. 

PURGING SALT WATER PUMP”.

[7] Display

Indicates the cell run time during normal operation, amperage or 

voltage by the control panel operation, and error codes in case of 

trouble.

[8] Dispense button

Press this button to start or stop dispensing electrolyzed water.

[9] Water outlet lamp

Indicates the type of water to be dispensed from each outlet.

Note: To maintain the desired settings, the unit automatically 

alternates the water outlets at regular intervals (every 12 hours 

at factory setting). Check the type of water to be dispensed from 

each outlet by the water outlet lamp.

 

The following dispensing modes are available:

 

Continuous dispensing mode

 

Activated or disactivated by pressing the dispense button or 

putting a hand or object in front of the dispensing sensor.

 

Portion control dispensing mode

 

Activated by pressing the dispense button for 3 seconds or 

putting a hand or object in front of the dispensing sensor for 3 

seconds. Water automatically stops after the set dispense time 

indicated in the display on the control panel (adjustable from 1 

to 60 minutes).

[c] CONTROL PANEL

[1] Display lamp (red)

Indicates the item currently displayed on the operation panel.

[2] * Button (down button)

When adjusting the settings, press this button to reduce the value.

[3] Set button

Press this button to adjust the settings. Should be used by qualified 

service personnel only. See the installation manual for details.

[4] Display select button (up button)

Press this button to select the indication in the display (electrolytic cell 

run time, current or voltage). The display lamp illuminates the selected 

item.

When adjusting the settings, press this button to raise the value.

[5] Flow rate select button

Adjusts the flow rate.

[6] Flow rate lamp (red)

Indicates the flow rate currently selected.

Note: When the low flow rate is selected, sanitizing water may have 

an  excessive  available  chlorine  concentration.  Select  this  flow 

rate only when the electrolyzed water property is inadequate.

[d] ACCESSORIES

pH test paper UNIV  Chlorine test paper  Instruction manual

Installation manual  Operation sheet 

Cap

Elbow 

Water supply hose  Pressure reducing valve

Salt water tank 

Shower nozzle 

O-ring [for shower nozzle]

Straight nozzle 

Gasket 

Nozzle hose [with gasket]

Measuring cup 

Wood screw 

Screw collar

Rubber dropper 

Nipple 

Dual check valve

3. CHECKS BEFORE OPERATION

[a] CHECKING AMOUNT OF REMAINING SALT WATER

1) Check that there is enough salt water in the salt water tank.

2) Add salt water according to “[b] SUPPLYING SALT WATER” if there 

is not enough or no salt water in the tank.

[b] SUPPLYING SALT WATER

CAUTION

Use sodium chloride (NaCl) or potassium chloride (KCl) of 

not less than 99% of purity. Use of any other salt may cause 

failure, clogged pipes or health problems.

  [1] 

 [6]

[2]

 

        [3] 

 

    [4] 

 

[5] 

Summary of Contents for ROX-10WB3-EW

Page 1: ...ROX 10WB3 EW L1X003115 032017 WATER ELECTROLYZER FOR END USER INSTRUCTION MANUAL 3 16 Minamiyakata Sakae Toyoake Aichi 470 1194 Japan...

Page 2: ...dance with current regulations according to the manufacturer s instructions This electrolyzer is not intended for outdoor use including under canopy Exposure to rain may cause electric leak or shock D...

Page 3: ...cathode Cl Negative ions drawn to anode Salt Water NaCl Diaphragm Electrolytic Cell Flow of electrons Cl H2O H2O Na Na Na Na Na OH OH 2e 2e H2 HOCl Reactions at Anode Chloride ions Cl and hydroxide i...

Page 4: ...r the set dispense time indicated in the display on the control panel adjustable from 1 to 60 minutes c CONTROL PANEL 1 Display lamp red Indicates the item currently displayed on the operation panel 2...

Page 5: ...UP 1 Plug in the unit 2 Open the water supply line shut off valve 3 Check for proper operation of the water softener Refer to the instruction manual provided for operating instructions See 9 f WATER H...

Page 6: ...e d CHECKING WATER SOFTENER Check that water from the water softener is soft Check that there is enough salt for refrigeration in the water softener For other instructions follow the instruction manua...

Page 7: ...mpany Only qualified personnel may repair the unit Do not attempt to repair it yourself e CELL RUN TIME CURRENT VOLTAGE AS REQUIRED To check the cell run time current and voltage 1 Open the control pa...

Page 8: ...ed Contact an authorized Hoshizaki service company E53 Reversing relay defective E61 Flow switching valve defective E84 Float switch defective None E74 Thermistor defective E82 Float switch defective...

Page 9: ...tion Salt water level Neutralizing agent level Water hardness Water leaks around unit Water leaks from water circuit Cell run time Checked by Sanitizing water only Date Time pH Sanitizing water Cleani...