42
IV. REMOVAL AND REPLACEMENT OF COMPONENTS
WARNING
Always unplug the unit or turn off the main power supply before replacing
components.
1. REFRIGERATION CIRCUIT
[a] REFRIGERANT
Refrigerant R134a used for this unit is not flammable or poisonous itself. It also provides
remarkably lower pressure than ammonia or similar substances at the same condensing
temperatures.
[b] COMPRESSOR
1) Remove the hexagon head bolt at the bottom of the front panel, and take off the front
panel.
2) Recover the refrigerant from the access valve, and store it in a proper container, if
required by an applicable law.
3) Remove the screws securing the condenser to the refrigeration unit base and the
shroud (condenser cover) to the cabinet, and pull out the condenser about 200 mm to
the front.
Front Panel
Control Box
Earth Wire
Hex Head Bolt
Unit Side Panel
Window Panel