![Hoshizaki FM-1000ALE Installation Manual Download Page 2](http://html1.mh-extra.com/html/hoshizaki/fm-1000ale/fm-1000ale_installation-manual_2165189002.webp)
92U2CM20B0303
ENGLISH
1
IMPORTANT
1. In order to carry out safe and proper
installation of the product, please read this
booklet carefully beforehand and follow the
instructions contained within.
2. On completion of the installation, start up the
icemaker to check for any abnormalities, and
instruct the user on how to use and maintain
the icemaker in accordance with the
Instruction Manual.
3. This booklet should be handed over to the
user after the installation and be preserved
by the user together with the Instruction
Manual for any further consultation that may
be necessary.
WARNING
The installation must be carried out by
qualified personnel
, in accordance with current
regulations, according to the manufacturer’s
instructions.
1. UNPACKING
WARNING
Children should not be allowed in reach of the
packaging elements (plastic bags and expanded
polystyrene) as they are potential sources of
danger.
CAUTION
Remove shipping carton, tape(s) and packing. If
packing material is left in the icemaker, it will not
work properly.
Note: 1. This icemaker needs a Storage Bin. The
recommended Storage Bin is HOSHIZAKI
ICE STORAGE BIN, Model B-500SD(PD),
B-700SD(PD) with Top Kit - 14C, or B-
900SD(PD) with Top Kit - 22C.
2. This icemaker is designed to be connected
with R22 (FM-1000ALE) or R404A (FM-
1000ALF) multi compressor rack system.
1) After removing the packaging, make sure that the
icemaker and the Storage Bin are in good condition.
If in doubt, please do not use the equipment but
apply to professionally qualified personnel. See the
instruction sheet attached to the Storage Bin for its
unpacking and installation guidelines.
2) Remove the shipping tape holding the Front Panel.
3) Remove the Front, Top and Side Panels. See Fig.
1.
4) Remove the package of accessories, and check
the contents:
a) Installation Kit
Inlet Hose
1
Outlet Hose
1
1/2-3/4 Nipple
1
3/4-3/4 Nipple
1
b) Scoop
1
c) Mounting Bracket
2
5) Remove the protective plastic film from the panels.
If the icemaker is exposed to the sun or to heat,
remove the film after the icemaker cools.
2. LOCATION
IMPORTANT
1. This icemaker is not intended for outdoor use.
Normal operating ambient temperature should
be within 5°C to 40°C. Normal operating water
temperature should be within 5°C to 35°C.
Operation of the icemaker, for extended
periods, outside of these normal temperature
ranges may affect production capacity.
2. The icemaker should not be located next to
ovens, grills or other high heat producing
equipment.
3. The location should provide a firm and level
foundation for the equipment.
Front Panel: Remove the screw. Lift up and
pull toward you.
Top Panel:
Remove the screw. Lift off.
Side Panel:
Remove the screw. Pull
slightly toward you, and lift off.
Fig. 1
Top Panel
Side Panel
Front Panel