25
REMEDY
2. LOW ICE PRODUCTION
[1] Abnormal
refrigeration
circuit.
[2] Condensing
temperature
too high.
[3] Poor water
flow.
a) Condenser
b) Thermostatic Expan-
sion Valve
c) Refrigerant Lines
d) Compressor Motor
Protector
e) Inside wall of
Evaporator
a) Condenser
b) Fan Motor
a) Water supply
PROBLEM
POSSIBLE CAUSE
1) Clean.
2) Remove anything blocking
vents.
1) Secure bulb to low-side
line or replace.
1) Check for leaks with a
leak detector. Reweld
leak, replace drier and
charge with refrigerant.
The amount of refrigerant
is marked on Nameplate.
2) Recharge.
1) Check Condenser and
Fan Motor.
1) Remove Auger, use
Hoshizaki “Scale Away”
or “LIME-A-WAY” solution
to clean periodically.
If water is found to sur-
pass the following levels,
install a conditioner:
Hardness 50 ppm
Silica 30 ppm
1) Clean.
2) Remove anything blocking
vents.
3) Check ventilation and
location, and change as
needed.
4) Allow proper clearance for
ventilation.
1) See chart 1 - [5] - a).
1) See chart 1 - [6] - a).
1) Dirty Air Filter or Condenser.
2) Bad ventilation.
1) Low-side pressure or tem-
perature exceeding the
limit.
1) Gas leaks.
2) Overcharged.
1) Overload Protector stops
Compressor intermittently.
1) Scale on inside wall of
Freezing Cylinder.
1) Dirty Air Filter or Condenser.
2) Bad ventilation.
3) Ambient temperature too
high.
4) Less than 6" clearance at
rear, sides and top.
1) Fan revolving too slowly.
1) Water pressure too low.
A2AAA0269806
Summary of Contents for DCM-240BAF
Page 8: ...8 A2AAA0269804 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT...
Page 9: ...9 A2AAA0269804 2 WIRING DIAGRAM...
Page 11: ...11 A2AAA0269806 RESERVOIR FILLS UP GEAR MOTOR TURNS ON...
Page 12: ...12 A2AAA0269806 COMPRESSOR STARTS 60 SEC AFTER GEAR MOTOR...
Page 13: ...13 A2AAA0269806 ICE MAKING CONTINUES...
Page 14: ...14 A2AAA0269806 BIN CONTROL SWITCH TRIPPED COMPRESSOR STOPS 90 SEC LATER...
Page 15: ...15 A2AAA0269806 GEAR MOTOR STOPS 60 SEC AFTER COMPRESSOR...
Page 16: ...16 A2AAA0269806 DISPENSE ICE BIN CONTROL STILL TRIPPED...
Page 17: ...17 A2AAA0269806 DISPENSE WATER BIN CONTROL STILL TRIPPED...
Page 19: ...19 A2AAA0269806 FLUSH SWITCH ACTIVATED...
Page 20: ...20 A2AAA0269806 FLUSH VALVE ACTIVATED WITH TIMER...
Page 21: ...21 A2AAA0269806 AGITATION TIMER ACTIVATES GEAR MOTOR...
Page 45: ...45 Fig 6 Fig 5 Middle Front Panel Thumbscrew Spout A Spout B A2AAA0269806...