Setting the On and Off Times

To alter these settings please proceed as follows:-

Press the
SET button
until SET
indicator
is next
to PROG
position

Use + and
- buttons
to adjust
day

Press
ENTER

Use + and
- buttons
to adjust
1st ON
time

Press
ENTER

Press
ENTER

Use + and
- buttons
to adjust
1st OFF
time

Repeat this
process for
2nd and 3rd
settings

Enter the 3rd
OFF time and
the word COPY
is displayed

To follow the copy
route and repeat all
programmed times for
another day go to 1

To set 
independent
times for other
days go to 2

Use the + and - buttons to
select day required and press COPY.
‘IN’ is displayed to confirm the copy.
Repeat for other days as required

To transfer to independent times
for other days go to 2 or to finish
programming press the SET button
until the SET indicator is in the RUN
position

1

Press ENTER. Use the + and - buttons 
to select the day required and 
press ENTER. Set 1st, 2nd and
3rd times as before. To repeat for
other days go to 2, to copy go to 1

To finish programming press the SET
button until the SET indicator is in
the RUN position

2

1st ON  

1st OFF   2nd ON   2nd OFF   3rd ON  

3rd OFF

6.30AM   8.30AM   12.00PM   12.00PM   4.30PM   10.30PM

Default Time settings

The default time settings shown above are preset at the factory 

NB. The factory default settings for the 2nd ON/OFF times are both 
set  at  12:00pm  (midday)  which  cancels  this  ‘ON’  period  giving  2 
ON/OFF periods for the day. If a midday ‘ON’ period is required set 
the 2nd ON and OFF times accordingly. If not press ENTER twice.

Summary of Contents for ServicePlus S17R Series 2

Page 1: ...hours on a weekly schedule and has a 1 hour manual boost and advance button to temporarily override current settings There is also a programming switch allowing permanent selection of OFF ON AUTO ALLD...

Page 2: ...ator RUN is the normal position 2 Time of day 3 Switch period symbol 4 SETbutton 5 BOOSTor adjust button 6 ADVANCE or adjust button 7 ENTER button 8 SELECTor COPYbutton 9 System ON indicator 10 SETpos...

Page 3: ...ogramming PM RUN CLOCK PROG AUTO ALL DAY 24 HRS OFF 6 35 BOOST Advance Function Brings forward the next on or off operation The advance facility will allow the user to advance the system to ON when cu...

Page 4: ...available All of the settings above will be permanent i e unaffected by programme times until alteration by the user The diagram below illustrates how to alter the setting it assumes that the program...

Page 5: ...e the and buttons to adjust the hour and press ENTER Use the and buttons to adjust the minutes and press ENTER Use the and buttons to set the date and press ENTER Use the and buttons to set the month...

Page 6: ...quired To transfer to independent times for other days go to 2 or to finish programming press the SET button until the SET indicator is in the RUN position 1 Press ENTER Use the and buttons to select...

Page 7: ...ET and SELECT buttons together as shown below After initial installation it is advisable before programming the ServicePlus for the first time to reset the unit Resetting can only be achieved with the...

Page 8: ...nd Repair This programmer is NOT user serviceable Please do not dismantle the unit In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of this user guide s...

Reviews: