Fitting the timeswitch

End view of CentaurPlus timer

If  surface  wiring  has  been  used,  remove  the  knockout/insert  from  the  bottom  of  the 
timeswitch to accommodate it.

Loosen  the  two  ‘captive’  retaining  screws  on  the  bottom  of  the  backplate.  Now  fit  the 
timeswitch to the backplate, ensuring the lugs on the backplate engage with the switch. 
Swing the bottom of the timeswitch into position ensuring that the connection pins on the 
back of the unit locate into the terminal slots in the backplate.

Tighten the two captive retaining screws to fix the unit securely.

Then switch on the mains supply.

On completion of the installation please reset the timeswitch as detailed next;

Resetting the timeswitch

On the CentaurPlus press the SET and SELECT buttons together. Then release the 
buttons and the timer will return to preset factory settings The preset factory settings 
are illustrated on page 10 of the USER GUIDE. The time and date will also be reset 
and need to be re-entered.

The unit is now ready to be signed on to its HRT4-ZW room thermostat, to suit the 
user’s requirements

5

Summary of Contents for CentaurPlus ZW

Page 1: ...g timeswitch with the CentaurPlus ZW will allow the room thermostat to be connected wirelessly producing immediate energy savings in houses where no previous room thermostat has been fitted The device...

Page 2: ...le circuit diagram for a typical combi boiler installation is shown below This diagram is schematic and should be used for guidance only N N E L L 1 2 3 4 For precise terminal connection information p...

Page 3: ...mounted remembering that the backplate fits to the left hand end of the control Mark the fixing positions through the slots on the backplate fixing centres of 60 3mm drill and plug the wall then secu...

Page 4: ...ty must be maintained and all bare earth connectors must be sleeved Ensure no earth conductors are left protruding outside the central space enclosed by the backplate Internal diagram C17 ZW The Centa...

Page 5: ...of the unit locate into the terminal slots in the backplate Tighten the two captive retaining screws to fix the unit securely Then switch on the mains supply On completion of the installation please r...

Page 6: ...IT During power interruptions the display will be blank after 3 days the current time of day will be lost These measures are to prolong the battery life SERVICEAND REPAIR This timeswitch is NOTuser se...

Page 7: ...ide optimum comfort with close control of the energy used to heat the home without the need for additional wiring or unsightly cable runs The HRT4 ZW will only operate when 2 x AAA batteries have been...

Page 8: ...o make the boiler switch on and off N B There is a half second delay in switching On and Off on receipt of the commands There is no click from the thermostat which is silent in operation but there wil...

Page 9: ...ollowing the procedure shown under Stage 1 of the pairing instructions Only use Stage 2 if a radio link cannot be successfully established between the two devices Stage 2 only used if above procedure...

Page 10: ...l far more efficiently than any traditional thermostat When used with a condensing boiler the TPI thermostat will help to save energy as the control algorithm allows the boiler to operate in condensin...

Page 11: ...Ensure that there will be enough space to allow easy access to the two retaining screws located at the base of the wall plate Before fixing the wall plate in position check to see that the thermostat...

Page 12: ...xtension to On period instant advance Mounting Industry standard 6 terminal plug in wall plate Transmitter Frequency 868MHz Design Standard EN60730 2 7 IP30 EN300 220 R TTE Directive EN301 489 Thermos...

Reviews: