Shaft monitoring
The system is able to display and monitor the
speeds of two shafts.
For this purpose enter the desired minimum
speeds for both shafts with the + and - keys.
Enter the number of pulses per revolution for
both shafts.
If the minimum speed is fallen short of an audible
and visible alarm will be emitted.
Fan monitoring
For fan monitoring the maximum speed can be
entered alongside the minimum speed.
For the fan the number of pulses per revolution
(2) must also be entered.
When the limit values are exceeded or fallen
short of an audible and visible alarm will be
emitted.
Tram line rhythm
Overview and selection of tram line
rhythm.
The "R-No" only represents the number from the
table and has no relevance for the rhythm.
The "Length" shows the number of bouts until
the rhythm repeats itself.
The fields "left" or "right" show the bout numbers
in which the seed hoses are closed.
The rhythm is determined by the width of the
drill and the working width of the care taking
machine (sprayer).
The rhythm for the corresponding combination
can be taken from the drawings.
After selecting the rhythm number from the table
the rhythm is displayed in the first line.
The second line with R-No. 999 can be used t
enter a freely programmable rhythm.