MAN0965-03-EN
Specifications/Installation
10/15/2013
No part of this publication may be reproduced without the prior agreement and written permission of Horner APG, LLC. Information in this document is subject to change without notice.
Page
5
of
6
Dec
Hex
Dec
Hex
Dec
Hex
Dec
Hex
Dec
Hex
Dec
Hex
Dec
Hex
Dec
Hex
Dec
Hex
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
1
0
1
29
1
D
57
3
9
86
5
6
114
7
2
142
8
E
170
A
A
198
C
6
226
E
2
2
0
2
30
1
E
58
3
A
87
5
7
115
7
2
143
8
F
171
A
B
199
C
7
227
E
3
3
0
3
31
1
F
59
3
B
88
5
8
116
7
4
144
9
0
172
A
C
200
C
8
228
E
4
4
0
4
32
2
0
60
3
C
89
5
9
117
7
5
145
9
1
173
A
D
201
C
9
229
E
5
5
0
5
33
2
1
61
3
D
90
5
A
118
7
6
146
9
2
174
A
E
202
C
A
230
E
6
6
0
6
34
2
2
62
3
E
91
5
B
119
7
7
147
9
3
175
A
F
203
C
B
231
E
7
7
0
7
35
2
3
63
3
F
92
5
C
120
7
8
148
9
4
176
B
0
204
C
C
232
E
8
8
0
8
36
2
4
64
4
0
93
5
D
121
7
9
149
9
5
177
B
1
205
C
D
233
E
9
9
0
9
37
2
5
65
4
1
94
5
E
122
7
A
150
9
6
178
B
2
206
C
E
234
E
A
10
0
A
38
2
6
66
4
2
95
5
F
123
7
B
151
9
7
179
B
3
207
C
F
235
E
B
11
0
B
39
2
7
67
4
3
96
6
0
124
7
C
152
9
8
180
B
4
208
D
0
236
E
C
12
0
C
40
2
8
68
4
4
97
6
1
125
7
D
153
9
9
181
B
5
209
D
1
237
E
D
13
0
D
41
2
9
69
4
5
98
6
2
126
7
E
154
9
A
182
B
6
210
D
2
238
E
E
14
0
E
42
2
A
70
4
6
99
6
3
127
7
F
155
9
B
183
B
7
211
D
3
239
E
F
15
0
F
43
2
B
72
4
8
100
6
4
128
8
0
156
9
C
184
B
8
212
D
4
240
F
0
16
1
0
44
2
C
73
4
9
101
6
5
129
8
1
157
9
D
185
B
9
213
D
5
241
F
1
17
1
1
45
2
D
74
4
A
102
6
6
130
8
2
158
9
E
186
B
A
214
D
6
242
F
2
18
1
2
46
2
E
75
4
B
103
6
7
131
8
3
159
9
F
187
B
B
215
D
7
243
F
3
19
1
3
47
2
F
76
4
C
104
6
8
132
8
4
160
A
0
188
B
C
216
D
8
244
F
4
20
1
4
48
3
0
77
4
D
105
6
9
133
8
5
161
A
1
189
B
D
217
D
9
245
F
5
21
1
5
49
3
1
78
4
E
106
6
A
134
8
6
162
A
2
190
B
E
218
D
A
246
F
6
22
1
6
50
3
2
79
4
F
107
6
B
135
8
7
163
A
3
191
B
F
219
D
B
247
F
7
23
1
7
51
3
3
80
5
0
108
6
C
136
8
8
164
A
4
192
C
0
220
D
C
248
F
8
24
1
8
52
3
4
81
5
1
109
6
D
137
8
9
165
A
5
193
C
1
221
D
D
249
F
9
25
1
9
53
3
5
82
5
2
110
6
E
138
8
A
166
A
6
194
C
2
222
D
E
250
F
A
26
1
A
54
3
6
83
5
3
111
6
F
139
8
B
167
A
7
195
C
3
223
D
F
251
F
B
27
1
B
55
3
7
84
5
4
112
7
0
140
8
C
168
A
8
196
C
4
224
E
0
252
F
C
28
1
C
56
3
8
85
5
5
113
7
1
141
8
D
169
A
9
197
C
5
225
E
1
253
F
D
8. LED INDICATORS
HE579DAC107 and HE579DAC207 provide diagnostic and status LED indicators
Diagnostic LED Indicators
Diagnostic LED
State
Meaning
MS
indicates fault status
of the Network
Solid Red
RAM or ROM test failed
Blinking Red
I/O test failed
Blinking Green
Module is in power-up state
Solid Green
Module is running normally
NS
Indicates fault status
of the Network
Solid Red
Network Ack or Dup ID test failed
Blinking Red
Network ID test failed
Blinking Green
Module is in Life Expectancy default state
Solid Green
Network is running normally
Status LED indicators
– The Power Status LED illuminates
RED
when power is applied to the module. There are I/O status LED
indicators for each of the Digital I/O points, which illuminate
RED