3.  WIRING 

 

 

 

 

 
 
 
 
 

Summary of Contents for SmartBlock HE579DAC107

Page 1: ...er Value for Nominal Full Scale 32000 GENERAL SPECIFICATIONS Required Power 24 VDC Voltage Mode 2KΩ 207 145mA 107 105mA Cooling Method Self cooling Relative Humidity 5 to 95 Non condensing Required Power 24 VDC Voltage Mode 2KΩ 207 255mA 107 190mA Altitude for use Up to 2 000m Pollution Degree 2 or lower Voltage Input 10 30 VDS Weight 12oz 340g Operating Temperature 0 to 60 C Atmosphere Free from ...

Page 2: ...ns Installation 10 15 2013 No part of this publication may be reproduced without the prior agreement and written permission of Horner APG LLC Information in this document is subject to change without notice Page 2 of 6 3 WIRING ...

Page 3: ...ck I O For advanced operations such as on the fly changes to the output type please see the following chapter on network data and the SmartStix and SmartBlock programming guide To configure SmartBlock I O from Cscape open the Hardware Configuration dialog from the Controller Hardware Configuration menu 1 Select the option for CsCAN I O 2 Click Add 3 Select the SmartStix Tab and select the device t...

Page 4: ...ed applications you may use NetPut functions to write this data Please see the advanced programming guide MAN0880 for more details Word Description 1 8 Analog Data Data for analog output channels 1 to 8 9 16 Default Data Analog output default state on error or stop if selected Produced Digital Data This data is sent from the SmartBlock to the controller Normally this data is mapped into specific r...

Page 5: ... 157 9 D 185 B 9 213 D 5 241 F 1 17 1 1 45 2 D 74 4 A 102 6 6 130 8 2 158 9 E 186 B A 214 D 6 242 F 2 18 1 2 46 2 E 75 4 B 103 6 7 131 8 3 159 9 F 187 B B 215 D 7 243 F 3 19 1 3 47 2 F 76 4 C 104 6 8 132 8 4 160 A 0 188 B C 216 D 8 244 F 4 20 1 4 48 3 0 77 4 D 105 6 9 133 8 5 161 A 1 189 B D 217 D 9 245 F 5 21 1 5 49 3 1 78 4 E 106 6 A 134 8 6 162 A 2 190 B E 218 D A 246 F 6 22 1 6 50 3 2 79 4 F 1...

Page 6: ...uracy will be affected Any thermocouple should be grounded in one place at most When found on the product the following symbols specify All applicable codes and standards need to be followed in the installation of this product For I O wiring discrete use the following wire type or equivalent Belden 9918 18 AWG or larger Adhere to the following safety precautions whenever any type of connection is ...