15
Battery Meter
The battery meter can check the battery’s total voltage, the
highest and lowest voltage, and each cell’s voltage.
Connect the battery’s balance wire to the meter’s balance socket.
Connect the battery to the charger’s output connector.
Press START/ENTER to enter the Lithium
Battery Meter program.
The screen indicates each cell’s voltage.
The screen indicates the highest, lowest, and
total voltage.
Battery Resistance Meter
The user can the check battery’s (1) total resistance, (2)
highest resistance, (3) lowest resistance, and (4) each cell’s
resistance. Connect the battery’s balance wire attached to the
meter’s balance socket. Connect the battery to the charger’s
output connector.
Press START/ENTER to enter the Lithium
Battery Resistance program.
The screen indicates each cell’s resistance.
The screen indicates the total, highest, and
lowest resistance.
Warning and Error Messages
The balance lead from the battery is not
connected to the charger, or it is faulty.
Incorrect polarity connected.
The current process has been interrupted.
Check all connections.
The battery connection is wrong or faulty.
The balance connection is wrong or faulty.
Input voltage is less than 11V.
Input voltage is greater than 18V.
The voltage of 1 cell in the battery pack is too low.
The voltage of 1 cell in the battery pack is too high.
The voltage of 1 cell in the battery pack is out
of normal range for the chemistry selected.
The cell number is wrong.
The internal battery temperature is too high.
The external battery temperature is too high.
The battery capacity has reached a mAh that
exceeds the set maximum capacity.
The charging time has reached the maximum
set charging time.
The battery voltage is higher than the set maxi-
mum voltage when charging in balance mode.
No power is allocated to the charger.
START/ENTER
BATT/PROGRAM
BATT METER
INC
4.20 4.19 4.19 V
4.18 0.00 0.00 V
MAIN 16.76V
H4.200V L4.182V
START/ENTER
BATT/PROGRAM
BATT RESISTANCE
INC
012 005 005 mΩ
006
mΩ
TOTAL: 28mΩ
H: 12mΩ
L: 5mΩ
REVERSE POLARITY
BALANCE WIRES
NOT CONNECTED
CONNECTION BREAK
CONNECT ERROR
CHECK MAIN PORT
BALANCE CONNECT
ERROR
CELL ERROR
LOW VOLTAGE
CELL ERROR
HIGH VOLTAGE
DC IN TOO LOW
DC IN TOO HIGH
CELL ERROR
VOLTAGE-INVALID
CELL NUMBER
INCORRECT
INT. TEMP. TOO HI
EXT. TEMP. TOO HI
OVER CHARGE
CAPACITY LIMIT
OVER THE LIMIT
BATTERY WAS FULL
NO POWER
DISTRIBUTED
Battery
This diagram shows the correct
way to connect your battery to
check the voltage.
Summary of Contents for Onyx KX80