Special Features

DC Power Supply

The Onyx

®

 KX80 is integrated with a DC power supply 

function with a 13.8V output and 10W–80W power range.

AGM Charge and Cold Charge

For Pb batteries, there are two charging modes: AGM charge 

and cold charge.

Optimized Operating Software

The Onyx KX80

 

features an AUTO function that automatically 

sets the current during charging/discharging. When charging 

lithium batteries, this may prevent overcharging. If the 

charger detects a malfunction, it will disconnect the circuit 

automatically and sound an alarm. You can configure the 

settings accordingly.

Battery Memory (Data Store/Load)

Store up to 10 different charge/discharge profiles for each 

channel. You can keep the data pertaining to program setting 

of the battery of continuous charging or discharging. Users 

can call out these data at any time without any special 

program setting.

Terminal Voltage Control (TVC)

TVC is the maximum voltage that a cell within a pack will 

charge to. Users cannot charge above the maximum voltage; 

however, users can charge to a lower termanal voltage, which 

will not fully charge a battery.

Internal Independent Lithium Battery Balancer

The Onyx KX80 features an individual cell voltage balancer, 

rendering an external balancer for balance charging 

unnecessary.

Balancing Individual Cells Battery During Discharging

During the process of discharging, the Onyx KX80 can 

monitor and balance each cell of the battery individually. An 

error message appears and the process automatically stops if 

the voltage of a single cell is abnormal.

•  See the status of individual Lithium cells (works with any 

charge, discharge and storage mode)

•  Capacity percentage 

•  Final voltage when the program ends

•  Input voltage

•  Safety timer and duration of time in minutes 

•  Cutoff temperature 

•  Internal and external temperature (Connect temperature 

probe to display external temperature.)

•  Capacity cut-off and value of the set capacity limit

Fast Charge and Storage Mode of Lithium Battery

Fast charge mode shortens the overall charge time required 

for lithium batteries with a slight reduction in overall capacity. 

Storage mode is used for charging or discharging lithium 

batteries not used for an extended period.

Re-Peak Mode of NiMH/NiCd Battery

In re-peak charge mode, the charger can peak charge the 

battery one, two, or three times in a row automatically. 

Delta-Peak Sensitivity for NiMH/NiCd Battery

When the battery’s voltage exceeds the threshold, the process 

automatically terminates.

Cyclic Charging/Discharging

A series of 1 to 5 charge to discharge (>) or discharge to 

charge cycles can be used for refreshing older batteries and 

improving cell balance.

Automatic Charging Current Limit

Allows you to set the upper limit of the charging current when 

charging your NiMH or NiCd battery.

Battery Meter

Allows you to check battery voltage and internal resistance.

Battery Internal Resistance Meter

Allows you to check the battery’s total internal resistance as 

well as each cell’s internal resistance.

Capacity Limit

The charging capacity is always calculated as the charging 

current multiplied by time. If the charging capacity exceeds 

the limit, the process automatically terminates when the 

maximum value is reached.

Temperature Threshold

The battery’s internal chemical reaction causes the battery 

temperature to rise. The process terminates if the temperature 

limit is reached. This function is only available when 

connecting the optional temperature probe (DYN5033).

Processing Time Limit

Allows you to limit the maximum process time to avoid 

overcharging the battery. 

Summary of Contents for Onyx KX80

Page 1: ...ONXC4101 80W AC DC Multi Chemistry Charger KX80...

Page 2: ...robability of property damage collateral damage and serious injury OR create a high probability of superficial injury CAUTION Procedures which if not properly followed create the probability of physic...

Page 3: ...process Always place the charger and the battery on a heat resistant inflammable and nonconductive surface Always keep all the inflammable volatile materials away from operating area Always keep the c...

Page 4: ...harging Cable Banana to Deans 4 DC Cable with Alligator Clip Connector 5 Balance adaptor JST XH 2 3 4 5 Balance Port LCD Display Resume or Start Charge Processes Temperature Sensor Port AC Socket 100...

Page 5: ...V cell Pb Cold 2 45V cell Balance Current 300mA cell Reading Voltage Range 0 1 26 1V cell Battery Types Cells NiMH NiCd 1 15 cells LiPo LiHV LiFe LiIon 1 6 cells Pb 2 20V Battery Capacity Range NiMH N...

Page 6: ...n the program ends Input voltage Safety timer and duration of time in minutes Cutoff temperature Internal and external temperature Connect temperature probe to display external temperature Capacity cu...

Page 7: ...4V 2S LiPo DISCHARGE 2 0A 7 4V 2S BATT PROGRAM LiFe BATT ENTER LiFe BALANCE CHG 2 0A 6 6V 2S LiFe CHARGE 2 0A 6 6V 2S LiFe FAST CHARGE 2 0A 6 6V 2S LiFe STORAGE 2 0A 6 6V 2S LiFe DISCHARGE 2 0A 6 6V...

Page 8: ...MORY 2 C 1 0A D 1 0A BATT MEMORY 2 NiMH 2 4V 2S ENTER SAVE PROGRAM SAVE SAVE PROGRAM ENTER DISCHG VOLTAGE 1 1V CELL DISCHG CURRENT 2 2A ENTER CHARGER LOAD NiMH CHARGE CURRENT 1 0A v NiMH Auto CHARGE C...

Page 9: ...n once The charger defaults to the most used battery type program Press the DEC or INC button to change the program mode from Normal Fast Charge Storage or Discharge Once finished press the BATT PROG...

Page 10: ...mber of cells of the battery pack before moving forward If the numbers are identical press START ENTER to start charging process 5 Charging Status Monitor During charging process real time status disp...

Page 11: ...condition of the battery connected to the output and automatically charges the battery CAUTION Never set the max charge current higher than 1C DISCHARGE This mode is for discharging NiMH NiCd battery...

Page 12: ...ower decreases accordingly DC Power Charger Power 80 Watts CAUTION The maximum DC Power output is 80W Please check your device before you allocate the power EXPLANATION OF LED STATUS OFF DC Power Off...

Page 13: ...er of cells 1S 6S Set the charge current 0 1 12 0A Set the discharge current 0 1A 2 0A Set the discharge voltage 3 0 3 3V Cell Set the terminal voltage 4 18 4 25V Press ENTER to save Indicate the batt...

Page 14: ...it Celsius Rest Time CHG DCHG 10Min Celsius Fahrenheit You can choose the temperature displayed as Celsius or Fahrenheit NiMH Sensitivity D Peak Default NiCD Sensitivity D Peak Default Key Beep ON Buz...

Page 15: ...nce connection is wrong or faulty Input voltage is less than 11V Input voltage is greater than 18V The voltage of 1 cell in the battery pack is too low The voltage of 1 cell in the battery pack is too...

Page 16: ...EEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Further in no event shall the liability of Horizon exceed the individual price of the Product on which liability is asserted As Horizon has no control ov...

Page 17: ...s the expense exceeds 50 of the retail purchase cost By submitting the item for service you are agreeing to payment of the service without notification Service estimates are available upon request You...

Page 18: ...tial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communi...

Page 19: ...19...

Page 20: ...2019 Horizon Hobby LLC Onyx IC3 and the Horizon Hobby Logo are trademarks or registered trademarks of Horizon Hobby LLC Created 04 2019 60591...

Reviews: