14
System Setting
The System Setting Screen displays the following information in sequence. These values can be changed by the user. To
change parameter values, press the START/ENTER button to make the value blink, then use the INC or DEC buttons to increase
or decrease the values. Store the values by pressing START/ENTER again.
Item
Selection
Description
NiMH Sensitivity
D.Peak Default
NiCD Sensitivity
D.Peak Default
Key Beep
ON
Buzzer ON
Load Factory Set
Enter
Version
HW: 1.00 FW: 1.10
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temp Cut-Off
On
50 C 122 F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
OFF/ON
(1-720 Min)
When you start a charge process, the integral safety timer automatically starts. This
prevents overcharging if a battery is faulty, or if the termination circuit cannot detect a
full charge. The value for the safety timer should allow a full charge of the battery.
NiMH Sensitivity
D.Peak Default
NiCD Sensitivity
D.Peak Default
Key Beep
ON
Buzzer ON
Load Factory Set
Enter
Version
HW: 1.00 FW: 1.10
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temp Cut-Off
On
50 C 122 F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
OFF/ON
(100–50000 mAh)
This program sets the maximum charge capacity that will be supplied to the battery
during charge. If the delta peak voltage is not detected or the safety timer expires for any
reason, this feature will automatically stop the process at the selected capacity value.
NiMH Sensitivity
D.Peak Default
NiCD Sensitivity
D.Peak Default
Key Beep
ON
Buzzer ON
Load Factory Set
Enter
Version
HW: 1.00 FW: 1.10
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temp Cut-Off
On
50 C 122 F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
OFF/ON
(20 C/68 F –
80 C/176 F)
The battery’s internal chemical reaction will cause the temperature of the battery to
rise. If the temperature limit is reached, the process will be terminated.
NiMH Sensitivity
D.Peak Default
NiCD Sensitivity
D.Peak Default
Key Beep
ON
Buzzer ON
Load Factory Set
Enter
Version
HW: 1.00 FW: 1.10
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temp Cut-Off
On
50 C 122 F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
Celsius
Fahrenheit
You can choose the temperature displayed as Celsius or Fahrenheit.
NiMH Sensitivity
D.Peak Default
NiCD Sensitivity
D.Peak Default
Key Beep
ON
Buzzer ON
Load Factory Set
Enter
Version
HW: 1.00 FW: 1.10
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temp Cut-Off
On
50 C 122 F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
1–60Min
A rest time allows the battery to cool down between charging/discharging cycles.
NiMH Sensitivity
D.Peak Default
NiCD Sensitivity
D.Peak Default
Key Beep
ON
Buzzer ON
Load Factory Set
Enter
Version
HW: 1.00 FW: 1.10
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temp Cut-Off
On
50 C 122 F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
Default: 4mV/Cell
3–15mV/Cell
This program is for NiMH/NiCd battery only. When the charger detects the delta peak
value you set, the charger will say the battery is fully charged.
A higher setting may be required in order to fully charge aged or under used batteries.
NiMH Sensitivity
D.Peak Default
NiCD Sensitivity
D.Peak Default
Key Beep
ON
Buzzer ON
Load Factory Set
Enter
Version
HW: 1.00 FW: 1.10
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temp Cut-Off
On
50 C 122 F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
NiMH Sensitivity
D.Peak Default
NiCD Sensitivity
D.Peak Default
Key Beep
ON
Buzzer ON
Load Factory Set
Enter
Version
HW: 1.00 FW: 1.10
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temp Cut-Off
On
50 C 122 F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
OFF/ON
The key beep sounds when the buttons are pushed to confirm your action. A beep or
buzzer sounds at various times during operation to alert different mode changes.
NiMH Sensitivity
D.Peak Default
NiCD Sensitivity
D.Peak Default
Key Beep
ON
Buzzer ON
Load Factory Set
Enter
Version
HW: 1.00 FW: 1.10
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temp Cut-Off
On
50 C 122 F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
Press ENTER to reset to the factory default settings.
NiMH Sensitivity
D.Peak Default
NiCD Sensitivity
D.Peak Default
Key Beep
ON
Buzzer ON
Load Factory Set
Enter
Version
HW: 1.00 FW: 1.10
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temp Cut-Off
On
50 C 122 F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
It indicates the hardware and firmware version.
Summary of Contents for Onyx KX80
Page 1: ...ONXC4101 80W AC DC Multi Chemistry Charger KX80...
Page 19: ...19...