4: Mechanical Troubleshooting
Mechanical Troubleshooting
4-6
Fold Rollers Do Not Rotate
Checking the fold roller rotating
- Remove the rear cover.
- Turn OFF the power switch. Keep pressing the [5]
button on the numeric key pad and turn ON the
power switch. The blower, valve, clutch and table
Up/Down motor repeat the cycle of feeding opera-
tion. (To stop, turn OFF the power switch.)
Drive belts are installed incorrectly.
Check the followings:
1.
The drive timing belts are installed and work
correctly.
2.
The fixing screws on the timing pulley are fully
tightened.
3.
The tension presses the belt correctly.
Drive Motor
M01
Fold
Rollers
Tension
SSR
M01
1
2
1
2
S00
X10 Q03 X12
X11
1 2
K02
2A
Capacitor
4-6: Fold Rollers Do Not Rotate
Drive motor M01 does not drive
Check the followings:
1.
The circuit protector Q03 for M01 is not
actuated.
2.
The fixing screws on timing pulley of the M01
are fully tightened.
3.
The voltage on the SSR terminal Pin2 and
BL connector X11 is 115/230VAC.
4.
Wiring and connection between S00 - M01
(shown above) is OK.
Summary of Contents for PF-P330
Page 2: ......
Page 9: ...1 1 1 1 Mechanism Mechanism 1 Mechanism ...
Page 21: ...2 2 1 2 Service Mode Service Mode 2 Service Mode ...
Page 24: ...2 4 2 Service Mode This page is intentionally left blank ...
Page 36: ...3 12 3 Adjusting and Checking Procedures This page is intentionally left blank ...
Page 37: ...4 4 1 4 Mechanical Troubleshooting Mechanical Troubleshooting 4 Mechanical Troubleshooting ...
Page 58: ...5 8 5 Folding Quality Troubleshooting This page is intentionally left blank ...
Page 59: ...6 6 1 6 Electrical Circuit Electrical Circuit 6 Electrical Circuit ...
Page 70: ...6 12 6 Electrical Circuit This page is intentionally left blank ...