4
4-3
4: Mechanical Troubleshooting
Mechanical Troubleshooting
4-2
Error Code 02 Is Indicated
(= Feed Table Does Not Lift)
The upper guide is raised.
The upper guide is held by a magnet. When the
upper guide is raised and remains there, the table
upper limit switch S01 works and stop the feed table.
Check the followings:
1.
An object on the feed table raises the upper
guide.
2.
An object sticks on the magnet that is installed
under the upper guide, and it raises the upper
guide.
3.
The upper guide is deformed and positions
apart from the S01.
Table upper limit switch S01
malfunctions.
Check the followings:
1.
S01 is installed correctly as shown in Section
[3-8: Table Upper Limit Switch S01 Position
Adjustment] , Fig.3.
2.
When raising the upper guide manually, the
LED L9 on QPM192 lights OFF.
3.
When raising the upper guide manually and
pushing down the actuator of the S01, L9
illuminates.
4.
Wiring and connection between the S01 and
Pin3,4 of CON3 on QPM192 is OK.
The feed table Up/Down mechanism
malfunctions.
See Section [4-1: Error Code 01 Is Indicated] and
check the same heading.
Height Detect Lever
Sensor
B06
Fulcrum
Upper Guide
S01
Magnet
CON3
L9
QPM-192
3
4
S01
ORN
YEL
NC
NO
C
4-2: Error Code 02 Is Indicated
The error code 02 is indicated when the
feed table upper limit sensor B06 does not
turn ON within 7 seconds after the signal to
lift the table has been sent.
The height detect lever of the sensor
B06 is raised.
On the back of the height detect lever, a thin iron chip
is attached. When the lever is raised by the sheets
and detected by the sensor B06, the feed table stops.
Check the followings:
1.
Installation and function of the height detect
lever.
2.
The installation of the iron chip on the back of
the height detect lever, and the B06.
3.
Wiring and connection between the B06 and
Pin1, 2 of CON10 on QPM192.
Summary of Contents for PF-P330
Page 2: ......
Page 9: ...1 1 1 1 Mechanism Mechanism 1 Mechanism ...
Page 21: ...2 2 1 2 Service Mode Service Mode 2 Service Mode ...
Page 24: ...2 4 2 Service Mode This page is intentionally left blank ...
Page 36: ...3 12 3 Adjusting and Checking Procedures This page is intentionally left blank ...
Page 37: ...4 4 1 4 Mechanical Troubleshooting Mechanical Troubleshooting 4 Mechanical Troubleshooting ...
Page 58: ...5 8 5 Folding Quality Troubleshooting This page is intentionally left blank ...
Page 59: ...6 6 1 6 Electrical Circuit Electrical Circuit 6 Electrical Circuit ...
Page 70: ...6 12 6 Electrical Circuit This page is intentionally left blank ...