2-2
2: Service Mode
On the numeric key pad, press the
button and turn ON the power switch.
On the numeric key pad, press the
button and turn ON the power switch.
On the numeric key pad, press the
button and turn ON the power switch.
On the numeric key pad, press the
button and turn ON the power switch.
On the numeric key pad, press the
button and turn ON the power switch.
On the numeric key pad, press the
button, turn ON the power switch and
wait for a while.
On the numeric key pad, press the
and turn ON the power switch.
When the folding pattern is NOT the Single
Fold, press the [0] button and [Feed Gap]
button.
2-1
Operations of Service Mode
In the service mode, the operations listed
on the chart to the right can be performed
by pressing the power switch and the other
switches together.
To quit the service mode, turn OFF the
power switch.
While the PF-P330 is performing the ser-
vice mode operations listed on the chart to
the right, the sheet sensor B08 is deacti-
vated. Therefore, the PF-P330 can run
without sheets on the feed table.
The first and second buckle chute stoppers move
Up/Down at full stroke.
The total counter is indicated.
(Total counter: The total number of the folding that is
counted since the machine has been shipped. This
is not cleared by pressing the [C] button.)
1
Buckle chute stopper Up/Down
2
Drive
motor drives
3
Feed table Up + Blower ON +
Clutch ON + Valve ON
4
Feed table Down +
Blower OFF + Clutch OFF + Valve OFF
Repeat
3
4
1
1
Drive motor Feed table Up and stops
2
Clutch repeats ON/OFF
1
Drive motor drives
2
Feed table Up +
Blower ON + Clutch ON + Valve ON
3
Feed
table Down + Blower OFF + Clutch OFF + Valve
OFF
Repeat
2
3
All stored memories are cleared.
(Keep pressing [C] button until the indication
appears while the power switch is ON. If the power
is turned OFF before the indication appears,
memories will not be cleared.
Total counter is reset to “0”
Solenoid Y02 and Y03 turn ON and the deflector
closes.
Buckle Chute
Single Moving
Mode
Total Counter
Indication
Non-Production
Run Mode
Clutch Unit Single
Operation Mode
Non-Production
Run Mode Except
Buckle Chute Unit
Memory
All Clear
Total Counter
Clear
Deflector Close
[1]
[2]
[3]
[4]
[5]
[C]
[O] & [C]
Summary of Contents for PF-P330
Page 2: ......
Page 9: ...1 1 1 1 Mechanism Mechanism 1 Mechanism ...
Page 21: ...2 2 1 2 Service Mode Service Mode 2 Service Mode ...
Page 24: ...2 4 2 Service Mode This page is intentionally left blank ...
Page 36: ...3 12 3 Adjusting and Checking Procedures This page is intentionally left blank ...
Page 37: ...4 4 1 4 Mechanical Troubleshooting Mechanical Troubleshooting 4 Mechanical Troubleshooting ...
Page 58: ...5 8 5 Folding Quality Troubleshooting This page is intentionally left blank ...
Page 59: ...6 6 1 6 Electrical Circuit Electrical Circuit 6 Electrical Circuit ...
Page 70: ...6 12 6 Electrical Circuit This page is intentionally left blank ...