background image

Page 8

24VF Gas Fireplace

Part No. XG0138

Horizon 

WARNING:

 

If you do not follow these instructions exactly, a fire or explosion 

may result causing property damage, personal injury or loss of life.

partment.

C.

  Use only your hand to push in or turn the gas control knob. 

Never use tools. If  the knob will not push in or turn by hand, 

don't try to repair it, call a qualified service technician. Force 

or attempt to repair may result in a fire or explosion.

D.

  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system, and 

any gas control which has been under water.

A.

  This appliance has a pilot which must be lit by hand. When 

lighting the pilot, follow these instructions exactly.

B.  BEFORE LIGHTING

 smell all around the appliance area for 

gas. Be sure to smell next to the floor because some gas is 

heavier than air and will settle on the floor.

 

What To Do If You Smell Gas:

  Do not try to light any appliance.

  Do not touch any electrical switch; do not use any phone 

in your building.

  Immediately call your gas supplier from a neighbour's 

phone. Follow the gas supplier's instructions.

  If you cannot reach your gas supplier, call the Fire De

-

To Turn Off Gas To Appliance:

Operating Instructions

1.

  Flip down the lower grill.

2.

  Push in gas control knob slightly and turn  

  clockwise 

to "Off".  Do not force.

3.

  Flip up the lower grill.

1.

 

STOP!  

Read the safety information above on this label.

2.

  Flip down the lower grill.

3.

  Push in gas control knob and turn clockwise 

  to "OFF."

4.

  Wait five (5) minutes to clear out any gas. Smell for gas, 

including near the floor. If you then smell gas, 

STOP!

 Follow 

"B" in the safety information above on this label. If you don't 

smell gas, go to the next step.

5.

  Locate pilot burner 

(See illustration at right.)

 and follow 

steps below.

6.

  Turn knob on gas control counterclockwise  

  to "PI

-

LOT."

7. 

Push in gas control knob completely and hold. Light with 

Piezo Igniter button. Continue to hold the control knob in for 

about (1) minute after the pilot is lit. Release the knob and it 

will pop back up. Pilot should remain lit. If it goes out repeat 

steps 3 through 8.

  If knob does not pop up when released. Stop and immedi

-

ately call your service technician or gas supplier.

  If the pilot will not stay lit after several tries, turn the gas 

control knob to "OFF" and call your service technician or 

gas supplier.

8.

  Push in gas control knob and turn counterclockwise  

  

adjusting the burner to the desired flame level '1' to '5'.

9.

  Flip up the lower grill.

Lighting  Instructions:

For Your Safety - READ BEFORE LIGHTING:

Gas Control 

Knob shown in 

Off position

Summary of Contents for 24VF

Page 1: ...ire or explosion may result causing propertydamage personalinjury or loss of life F o r Y o u r Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combus tion and ventilation air must be provided Refer to page 3...

Page 2: ... are in the same room as the appliance Clothing or other flammable materials should not be placed on or near the appliance Any safety screen or guard removed for servicing an ap pliance must be replaced prior to operating the heater Installationandrepairshouldbedonebyaqualifiedservice person The appliance should be inspected before use and at least annually by a professional service person Morefre...

Page 3: ... barrier This will reduce the possibility of a cold air convection current on the fireplace Space Requirements This heater must not be installed in a confined space or unusually tight construction unless provisions are made for adequate combus tion and ventilation air The National Fuel Gas Code ANSI Z223 1 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 BTU pe...

Page 4: ...valve pressure measuring port If leaks are determined then repair and repeat the pressure test procedure 5 Turn main gas control pilot knob OFF during any pressure testing Test pressure should be equal to or less than 3 5 kPa to prevent dam age to control valve 6 Installation requirements and combustion and ventilation air provi sions must conform with local codes 7 Keep the operating area clear a...

Page 5: ...Y WAY to do so restricts the air supply for the control compartments and it also prevents access for servic ing controls The face of the fireplace may be painted to match the room decor provided you use a heat resistant paint Decorative facing must not extend past the fireplace opening at all because it will interfere with the access to retainers for removal of screen door Figure 6 Combustible man...

Page 6: ...lling the Logset Installing the Logs The 24VF is supplied with a two piece fibre logset The logset is very fragile and must be handled very carefully 1 Remove the screen door as shown in figure 8a 2 To install the logs place the rear log in place on the rear log rest Ensure that the log is centered in place as shown below Place the front log in place on the front logrest and center it in place 3 R...

Page 7: ...m then the room is an unconfined space and qualifies for unvented heater installation If the result is less than the accumulated BTU of all the appliances in the room then the room is a confined space and the unvented heater should not be installed in such a small room This heater shall not be installed in a room with unusually tight construction as defined as follows Walls and ceilings exposed to...

Page 8: ... supplier call the Fire De To Turn Off Gas To Appliance Operating Instructions 1 Flip down the lower grill 2 Push in gas control knob slightly and turn clockwise to Off Do not force 3 Flip up the lower grill 1 STOP Read the safety information above on this label 2 Flip down the lower grill 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas...

Page 9: ...ce if any part has been under water Imme diately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Operating Instructions Lighting Instructions See page 8 Burner Adjustment The 24VF is equipped with an adjustable burner allowing you to raise or lower the flames 1 Light the pilot as per the light...

Page 10: ...rs This is available at hardware and computer stores and is sometimes labelled as a duster Do NOT use an air compressor as the air from a compressor usually contains oil The correct product usu ally has a small straw that connects to the can to aim the air Cleaning the ODS Sensor Must be performed by a certified gas technician 1 Locate the pilot assembly on your stove 2 Turn on the gas valve on th...

Page 11: ...ce these parts CORRECTIVE ACTION Push the knob in at PILOT position and spark piezo ignitor for at least 10 seconds If pilot does not light repeat 2 or 3 more times If pilot still does not light call a certified technician Bleed air from line eliminate draft make sure gas is going to pilot Ventilate room and let stove burn for a while Ventilate room and stop using odor causing products while stove...

Page 12: ...Page 12 24VF Gas Fireplace Part No XG0138 Horizon Notes ...

Page 13: ...manufactured or supplied by Montigo DelRay Corp 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and unde...

Page 14: ...Canadian Heating Products 27342 Gloucester Way Langley BC XG0138 122006 Installed and Serviced by Horizon ...

Reviews: