The Warranty

Montigo DelRay Corp. warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, 
there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas 
control valve and fibre logs. Screen, plated/painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by Montigo DelRay Corp..
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see Montigo DelRay Corp. right of inves-
tigation outlined below). Montigo DelRay Corp. will, at its option, replace or repair defective components of the Gas Appliance manufactured by Montigo DelRay 
Corp. at no charge, and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially 
practical, Montigo DelRay Corp. will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall Montigo DelRay Corp. be responsible for materials, components, or construction 
which are not manufactured or supplied by Montigo DelRay Corp., or for the labour necessary to install, repair or remove such materials, components or construc-
tion. All replacement or repair components will be shipped F.O.B. the nearest Montigo DelRay Corp. factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with Montigo DelRay Corp. installation instructions and local building codes. The Warranty on this 

Montigo Gas Appliance covers only the component parts manufactured by Montigo DelRay Corp.. The use of components manufactured by others with this 
Montigo Gas Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be 
in violation of local building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by 
Montigo DelRay Corp. 

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that Montigo DelRay Corp. sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 
expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall Montigo DelRay Corp. be responsible for any incidental or consequential damages caused by defects in its products, whether such damage 
occurs or is discovered before or after replacement or repair, and whether or not such damage is caused by Montigo DelRay Corp. negligence. Some states do 
not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied 
warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied 
warranty lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

Montigo DelRay Corp. reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
Montigo DelRay Corp. Are Not Responsible For Work Done Without Written Consent
Montigo DelRay Corp. shall in no event be responsible for any warranty work done without first obtaining Montigo DelRay Corp. written consent.
Dealers Have No Authority To Alter This Warranty
Montigo DelRay Corp. employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those 
stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, Montigo DelRay Corp. must be notified of the claimed defect in writing or by telephone, as soon as reasonably 
possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, specifica-
tions, prices and also to discontinue colors, styles and products.

Warranty

Summary of Contents for 24VF

Page 1: ...ire or explosion may result causing propertydamage personalinjury or loss of life F o r Y o u r Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combus tion and ventilation air must be provided Refer to page 3...

Page 2: ... are in the same room as the appliance Clothing or other flammable materials should not be placed on or near the appliance Any safety screen or guard removed for servicing an ap pliance must be replaced prior to operating the heater Installationandrepairshouldbedonebyaqualifiedservice person The appliance should be inspected before use and at least annually by a professional service person Morefre...

Page 3: ... barrier This will reduce the possibility of a cold air convection current on the fireplace Space Requirements This heater must not be installed in a confined space or unusually tight construction unless provisions are made for adequate combus tion and ventilation air The National Fuel Gas Code ANSI Z223 1 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 BTU pe...

Page 4: ...valve pressure measuring port If leaks are determined then repair and repeat the pressure test procedure 5 Turn main gas control pilot knob OFF during any pressure testing Test pressure should be equal to or less than 3 5 kPa to prevent dam age to control valve 6 Installation requirements and combustion and ventilation air provi sions must conform with local codes 7 Keep the operating area clear a...

Page 5: ...Y WAY to do so restricts the air supply for the control compartments and it also prevents access for servic ing controls The face of the fireplace may be painted to match the room decor provided you use a heat resistant paint Decorative facing must not extend past the fireplace opening at all because it will interfere with the access to retainers for removal of screen door Figure 6 Combustible man...

Page 6: ...lling the Logset Installing the Logs The 24VF is supplied with a two piece fibre logset The logset is very fragile and must be handled very carefully 1 Remove the screen door as shown in figure 8a 2 To install the logs place the rear log in place on the rear log rest Ensure that the log is centered in place as shown below Place the front log in place on the front logrest and center it in place 3 R...

Page 7: ...m then the room is an unconfined space and qualifies for unvented heater installation If the result is less than the accumulated BTU of all the appliances in the room then the room is a confined space and the unvented heater should not be installed in such a small room This heater shall not be installed in a room with unusually tight construction as defined as follows Walls and ceilings exposed to...

Page 8: ... supplier call the Fire De To Turn Off Gas To Appliance Operating Instructions 1 Flip down the lower grill 2 Push in gas control knob slightly and turn clockwise to Off Do not force 3 Flip up the lower grill 1 STOP Read the safety information above on this label 2 Flip down the lower grill 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas...

Page 9: ...ce if any part has been under water Imme diately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Operating Instructions Lighting Instructions See page 8 Burner Adjustment The 24VF is equipped with an adjustable burner allowing you to raise or lower the flames 1 Light the pilot as per the light...

Page 10: ...rs This is available at hardware and computer stores and is sometimes labelled as a duster Do NOT use an air compressor as the air from a compressor usually contains oil The correct product usu ally has a small straw that connects to the can to aim the air Cleaning the ODS Sensor Must be performed by a certified gas technician 1 Locate the pilot assembly on your stove 2 Turn on the gas valve on th...

Page 11: ...ce these parts CORRECTIVE ACTION Push the knob in at PILOT position and spark piezo ignitor for at least 10 seconds If pilot does not light repeat 2 or 3 more times If pilot still does not light call a certified technician Bleed air from line eliminate draft make sure gas is going to pilot Ventilate room and let stove burn for a while Ventilate room and stop using odor causing products while stove...

Page 12: ...Page 12 24VF Gas Fireplace Part No XG0138 Horizon Notes ...

Page 13: ...manufactured or supplied by Montigo DelRay Corp 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and unde...

Page 14: ...Canadian Heating Products 27342 Gloucester Way Langley BC XG0138 122006 Installed and Serviced by Horizon ...