Installation Instructions Horizon Natural Draft Electronic Ignition 3 Sided Gas Fireplaces
2
Location Requirements
Horizon natural draft electronic ignition fireplaces are
designed to be installed as a complete fireplace system.
The firebox incorporates a gas burner with electronic
ignition and spiggot for attaching a flue. The flue needs
to run vertically and exit above the roof line. 45 degree
bends can be utilised. All A.G.A requirements for flues are
to be observed when installing.
Room Ventilation Requirements:
Rooms with gas open fires require fresh air vents a per
gas regulations. For example:
1 x VENT REQUIRED
Natural Draft Electronic
Ignition approved for the
following models:
SUITABLE GAS BURNER OPTION
DOUBLE SIDED MODELS
700 Low Line
700 Mk2 Pebble
700 Mk2 Coal
850 Low Line
800 Mk2 Pebble
800 Mk2 Coal
1100 Low Line
1000 Mk2 Pebble
1000 Mk2 Coal
1500 Low Line
1400 Mk2 Pebble
1400 Mk2 Coal
2000 Low Line
1800 Mk2 Pebble
1800 Mk2 Coal
SINGLE SIDED MODELS
700 Low Line
700 Mk2 Pebble
700 Mk2 Coal
700 Ironbark Log Mk4
850 Low Line
800 Mk2 Pebble
800 Mk2 Coal
850 Ironbark Log Mk4
1100 Low Line
1000 Mk2 Pebble
1000 Mk2 Coal
850 Ironbark Log Mk4
1500 Low Line
1400 Mk2 Pebble
1400 Mk2 Coal
2000 Low Line
1800 Mk2 Pebble
1800 Mk2 Coal
CANTILEVER
700 Cantilever
700 Mk2 Pebble
700 Mk2 Coal
700 Ironbark Log Mk4
1100 Cantilever
1000 Mk2 Pebble
1000 Mk2 Coal
850 Ironbark Log Mk4
* Custom sizes available.
Model Type 2: Natural Draft
Electronic Ignition Gas Fireplace
DATA PLATE: Refer to data plate for information in respect to
gas pressure, consumption and gas type, (Natural or LPG).
Data Plate is located under the gas burner and is accessed
by lifting front access panel or removing base plate.
2 x VENTS REQUIRED
VENTILATION:
An opening to outside with a minimum
free ventilation area of 400sq centimetres for each
decorative gas fire.
NOTE:
The chimney in which the appliance is installed
is not to be considered as a ventilation opening
270mm
125mm
430mm
125mm