14
the shunt installed, both forward and reverse LTC is generated. With the shunt removed, the LTC OUT waveform is always in
the forward direction regardless of the apparent tape direction from which the VITC is read.
Factory setting allows both forward and reverse LTC generation (shunt installed).
SRH OFFSET Jumper
The "SRH OFFSET" jumper enables application of a "-1 frame" offset to the generated LTC number during VITC-to-LTC
translation when the VITC source VCR is at search speeds (especially slow and still-framed). Search offset is enabled when the
shunt is installed and disabled otherwise.
Factory setting is to enable search offset (shunt installed).
FRAMES Jumper
With a shunt installed on the "FRAMES" jumper the frames digits are displayed at tape speeds below two times play during either
LTC or VITC reader operation. With no shunt installed the frames digits are always blanked in all reader and all generator
modes.
Factory setting allows framed digits display (shunt installed).