output signal to this video; otherwise the LTC generator free runs at an approximate 29.97 frames-per-second rate. 
 

Generator Run/Stop 

 

Each  time  the  mode  switch  is  momentarily  positioned  to  SET  and  then  released  back  to  GEN  LTC,  the  VLR-100  alternately 
starts and stops incrementing the LTC numbers.  When the generator is incrementing, the LTC colon LED blinks rapidly.  When 
stopped, the LTC colon LED blinks at a ¼-second on/off rate. 
 

Presetting the Time Code 

 

The  VLR-100  LTC  Generator  starting  value  is  preset  using  the  MODE  switch.    When  the  MODE  switch  is  held  in  the  SET 
position for two seconds, the minute, second and frame digits are preset to 00 while the hour digits flash the current hours value 
on and off.  Alternate activation/release of the MODE switch to/from the SET position causes the hour digits to count up to 23 
and then start over at 00.  The MODE switch can also be held in the SET position to force automatic counting of the hour digits. 

 

Once the MODE switch has remained released from its SET position for two seconds, the preset operation moves to the minute 
digits.  Starting from 00 the minute digits can be counted up to 59 in a similar  manner as the hours.  Once the MODE switch 
remains  released  from  its  SET  position  for  two  seconds,  the  minutes  preset  operation  finishes.    If  no  counting  of  the  minute 
digits is performed (i.e., MODE was never pressed to SET), the minute digits simply flash on and off for two seconds and then 
the operation completes, leaving the minutes value at 00. 

 

Except for jamsync and auto-backtime operations (both described further on), the seconds and frames are always preset to 00.  
After presetting the minutes, the preset operation moves on to selection of drop frame or non-drop frame time code generation 
indicated by the DF LED blinking on and off.  Alternating the MODE switch to/from the SET position toggles between drop and 
non-drop frame generation, forcing the DF LED on or off, respectively.  Once the MODE switch has remained inactive for one 
second, the drop frame preset operation completes. 

 

At this point, the LTC colon LED begins to blink, indicating that the LTC generator is ready to run. 
 

Presetting the User Bits 

 

When the DATA switch is in the UB position, the user bits can be preset in much the same manner as used for presetting the 
time code.  Presetting the user bits does not affect the time code value.  When the MODE switch is held in the SET position for 
one second, the left most user bit digit blinks on and off, and can be preset to any value between 0 through 9 and A, B, C, D, E 
and F, starting from its current value.  Once the MODE switch remains inactive for one second, the preset operation moves on to 
the next user bit digit until all eight have been given the opportunity to be preset. 

 

If you wish to "auto-clear" all of the user bit digits before setting them (without affecting the time code value), continue to hold 
the MODE switch in the SET position for one additional second after the left most digit first begins blinking. 
 

Ending the Preset Cycle 

 

If left on its own, the VLR-100 automatically ends the preset operation after several seconds.  However, the preset operation can 
be manually terminated at any time by switching the DATA switch between its TC and UB positions.  Any time code or user bit 
values you have preset so far remain in effect, and operation proceeds directly to starting the generator. 
 

Automatic Backtime Preset 

 

On  a  record  master  tape  that  is  pre-striped  with  time  code  and  black  burst  (or  color  bars  and  then  black  burst),  it  is  often 
desirable  to  have  a  "leader"  of  30,  60,  or  more  seconds  before  the  time  code  number  "rolls  through  zero"  and  the  first  edit  is 
performed.  Performing the first edit at time zero allows the time code number to indicate the length of the program in addition 
to the location of edits. 

 

Automatic backtime preset allows the generator to be preset to a starting time "in front of" zero.  The backtime preset value can 
be selected from -30, -60, -90, or -120 seconds. 

 

If the MODE switch is held in its SET position while the VLR-100 is powered up, the automatic backtime preset selection mode 
is  immediately  entered.    As  long  as  MODE  remains  in  the  SET  position,  the  display  will  sequentially  change  between 
00:00:30:00, 00:01:00:00, 00:01:30:00, and 00:02:00:00, once per second.  The time last displayed  when the MODE switch is 
released from the SET position becomes the amount of time automatically subtracted from the generator's start time whenever it 
is preset. 

 

For  example,  the  VLR-100  LTC  generator  normally  starts  at  00:00:00:00  at  power  up.    If  automatic  backtime  mode  is  set  to 
00:00:30:00 (30 seconds), then the generator presets to 23:59:30:00.  The automatic backtime mode remains in effect until the 

Summary of Contents for VLR-100

Page 1: ...VLR 100 SMPTE VITC LTC CODE READER LTC GENERATOR LED DISPLAY USER MANUAL For Models VLR 100 and VLR 100PC Doc 072450 00 Rev F C Copyright 2014 P O Box 3993 Mission Viejo CA 92690 949 489 0240 www hor...

Page 2: ...by any means without prior written consent of HORITA CO INC P O Box 3993 Mission Viejo CA 92690 HORITA CO INC makes no warranties with respect to this documentation and disclaims any warranties of me...

Page 3: ...Code Source 5 1 LTC Reader Operation 5 1 VITC Reader Operation 5 2 5 2 LTC Generator Operation 5 2 Generator RUN STOP 5 3 Presetting the Time Code 5 3 Presetting the User Bits 5 4 Ending the Preset Cy...

Page 4: ...iii...

Page 5: ...speed forward and reverse depending upon tape format Manual preset of LTC generator or jam sync from LTC or VITC reader Supports both drop and non drop frame time code Translates VITC to LTC 0 56 high...

Page 6: ...2...

Page 7: ...cated in the vertical interval of a standard television picture VITC is typically recorded on two non adjacent lines of the vertical interval of each composite video field In addition to containing th...

Page 8: ...s often avoided elsewhere due to the nature of it s unconventional numbering system If it is a requirement that the time code numbers you read from your time coded tapes represent real time within 3 6...

Page 9: ...s track levels for recording LTC An internal jumper allows adjustment of the LTC OUT signal risetime See Section 6 for further details 4 3 Connecting VITC In and Out Connect the video source supplying...

Page 10: ...e with Black Burst and LTC 4 5 Connecting Serial COMM VLR 100PC Only The HORITA supplied serial interface cable connects the VLR 100PC COMM connector 3 5mm phone jack to a DB 9 male connector compatib...

Page 11: ...C Reader Operation The VLR 100 reads VITC in both forward and reverse directions from pause on up to fast search There is no VITC line number selection for the VLR 100 The VLR 100 reads the first line...

Page 12: ...same manner as used for presetting the time code Presetting the user bits does not affect the time code value When the MODE switch is held in the SET position for one second the left most user bit di...

Page 13: ...preset the LTC generator user bits to a desired value for example to indicate a tape reel number when making a copy of the tape but still jamsync the time code to the correct value If all eight user b...

Page 14: ...updating or 1 frame However when the VCR is in search mode and is still framed adding an extra count to the translated time code number causes the frame number to be ahead by one To compensate for th...

Page 15: ...a 1 second rate to indicate loss of input video LTC If the VLR 100 is operating as an LTC reader the LTC LED blinks rapidly whenever incoming LTC is being actively read As with the VITC LED the LTC LE...

Page 16: ...12...

Page 17: ...locations of these jumpers are shown in Figure 6 1 LTC OUT FRAMES 1 5VITC LTCOUT F R SRH OFFSET Figure 6 1 Jumper Locations LTC Output Rise Time Jumper The LTC OUT jumper allows adjustment of the LTC...

Page 18: ...ed LTC number during VITC to LTC translation when the VITC source VCR is at search speeds especially slow and still framed Search offset is enabled when the shunt is installed and disabled otherwise F...

Page 19: ...SELECT Three position toggle switch DATA Toggle switch MODE Three position toggle switch DISPLAY Momentary toggle switch POWER ON OFF Toggle switch BRIGHT Brightness adjustment Environment Operating 5...

Reviews: