MAINTENANCE 

 

6.1 Cleaning 

 

  1. Do not attempt to disassemble your VLR-100 to clean it. 

 

  2. Clean your VLR-100 using only a damp cloth. 

  

  3. NEVER use water or solvents such as alcohol, window cleaner,  etc., to clean your VLR-100. 
 

6.2 Service and Troubleshooting 

 

If you suspect your VLR-100 is not operating properly, check the following: 

 

  1. Check all cables for opens or shorts. 

 

  2. If using an AC power adapter different from the one supplied with the VLR-100, make sure it supplies the VLR-100 with at 

least 9 volts (maximum of 14 volts) when the VLR-100 is switched on. 

 

You  may  return  your  VLR-100  to  HORITA  for  service.    Please  contact  HORITA  Co.  first,  either  by  phone  or  mail,  before 
returning your unit. 
 

6.3 Adjustments 

 

Internal jumper selections are provided for LTC OUT rise time control, VITC backup limits, VITC-to-LTC translation options, 
and time code frame digit blanking. 

 

To  access  these  jumpers,  remove  the  top  cover  from  the  VLR-100    by  removing  the  six  hex  screws.    The  locations  of  these 
jumpers are shown in Figure 6-1. 

 

LTC OUT

FRAMES

<1/5VITC

LTCOUT F&R

SRH OFFSET

 

 

Figure 6-1, Jumper Locations 

 

LTC Output Rise Time Jumper 

 

The LTC OUT jumper allows adjustment of the LTC output waveform rise time both when regenerating the reader LTC IN signal 
and for the output of the LTC generator.  With a shunt installed, the rise time of the LTC output is limited to 25uS, ±5uS.  With 
no shunt installed, wide band LTC is regenerated. 
 
Factory setting is wide band (shunt removed). 
 

<1/5 VITC Jumper 

 

When  automatic  reader  mode  is  selected  (i.e.,  MODE  in  RDR  position  and  SELECT  in  AUTO  position),  the  "<1/5  VITC" 
internal jumper further defines the switching behavior between LTC and VITC.  With a shunt installed, the automatic backup of 
the LTC reader by the VITC reader is restricted to tape speeds below 1/5th times play speed.  When no shunt is installed, VITC 
can backup LTC at all tape speeds.  Note that this jumper has no effect on VITC-to-LTC translation. 
 
Factory setting is VITC backup at all tape speeds (shunt removed). 
 

LTCOUT F&R Jumper 

 

The "LTCOUT F&R" jumper controls the allowable direction of the generated LTC OUT during VITC-to-LTC translation.  With 

Summary of Contents for VLR-100

Page 1: ...VLR 100 SMPTE VITC LTC CODE READER LTC GENERATOR LED DISPLAY USER MANUAL For Models VLR 100 and VLR 100PC Doc 072450 00 Rev F C Copyright 2014 P O Box 3993 Mission Viejo CA 92690 949 489 0240 www hor...

Page 2: ...by any means without prior written consent of HORITA CO INC P O Box 3993 Mission Viejo CA 92690 HORITA CO INC makes no warranties with respect to this documentation and disclaims any warranties of me...

Page 3: ...Code Source 5 1 LTC Reader Operation 5 1 VITC Reader Operation 5 2 5 2 LTC Generator Operation 5 2 Generator RUN STOP 5 3 Presetting the Time Code 5 3 Presetting the User Bits 5 4 Ending the Preset Cy...

Page 4: ...iii...

Page 5: ...speed forward and reverse depending upon tape format Manual preset of LTC generator or jam sync from LTC or VITC reader Supports both drop and non drop frame time code Translates VITC to LTC 0 56 high...

Page 6: ...2...

Page 7: ...cated in the vertical interval of a standard television picture VITC is typically recorded on two non adjacent lines of the vertical interval of each composite video field In addition to containing th...

Page 8: ...s often avoided elsewhere due to the nature of it s unconventional numbering system If it is a requirement that the time code numbers you read from your time coded tapes represent real time within 3 6...

Page 9: ...s track levels for recording LTC An internal jumper allows adjustment of the LTC OUT signal risetime See Section 6 for further details 4 3 Connecting VITC In and Out Connect the video source supplying...

Page 10: ...e with Black Burst and LTC 4 5 Connecting Serial COMM VLR 100PC Only The HORITA supplied serial interface cable connects the VLR 100PC COMM connector 3 5mm phone jack to a DB 9 male connector compatib...

Page 11: ...C Reader Operation The VLR 100 reads VITC in both forward and reverse directions from pause on up to fast search There is no VITC line number selection for the VLR 100 The VLR 100 reads the first line...

Page 12: ...same manner as used for presetting the time code Presetting the user bits does not affect the time code value When the MODE switch is held in the SET position for one second the left most user bit di...

Page 13: ...preset the LTC generator user bits to a desired value for example to indicate a tape reel number when making a copy of the tape but still jamsync the time code to the correct value If all eight user b...

Page 14: ...updating or 1 frame However when the VCR is in search mode and is still framed adding an extra count to the translated time code number causes the frame number to be ahead by one To compensate for th...

Page 15: ...a 1 second rate to indicate loss of input video LTC If the VLR 100 is operating as an LTC reader the LTC LED blinks rapidly whenever incoming LTC is being actively read As with the VITC LED the LTC LE...

Page 16: ...12...

Page 17: ...locations of these jumpers are shown in Figure 6 1 LTC OUT FRAMES 1 5VITC LTCOUT F R SRH OFFSET Figure 6 1 Jumper Locations LTC Output Rise Time Jumper The LTC OUT jumper allows adjustment of the LTC...

Page 18: ...ed LTC number during VITC to LTC translation when the VITC source VCR is at search speeds especially slow and still framed Search offset is enabled when the shunt is installed and disabled otherwise F...

Page 19: ...SELECT Three position toggle switch DATA Toggle switch MODE Three position toggle switch DISPLAY Momentary toggle switch POWER ON OFF Toggle switch BRIGHT Brightness adjustment Environment Operating 5...

Reviews: