HORITA HOR-TRG-100 User Manual Download Page 16

 

 

16 

You  may  return  your  TRG-100  to  HORITA  for  service.  Please  contact  HORITA  first,  either  by  phone  or  mail,  before 
returning your unit. 
 
Note that there are no adjustments or user serviceable parts inside the TRG-100. 
 

7

  

SPECIFICATIONS 

 
NOTE: us = microseconds,  ms = milliseconds,  mA = milliamp,  mV = millivolt 
 

Power 

  Operation 

9-to-12V  DC, apprx. 300 mA.  

  Connector 

Mini phone plug, 3.5mm (0.125"), center positive 

  AC Adapter 

9 volt, 500 mA.  

 

Video/Tri-Level Sync 

  IN/OUT 
  Level 

Standard definition NTSC or PAL 1V P-P composite video, HD Tri-Level Sync input 

  Connector 

BNC -  Looping, must be externally terminated at 75-ohms for proper operation 

 

Un-Balanced Time Code 

  IN -   Level 

200mV-to -10V P-P 

        Connector 

RCA 

 
  OUT -Level 

1.6V P-P square wave. Rise time approximately 35us 

            Connector 

RCA 

 

Balanced Time Code 

  IN -    Level 

Ba/- 200mV to +/- 10V P-P square wave. 

         Connector 

Female XLR-3,  1=GND, 2=TC+, 3=TC- 

 
  OUT - Level 

Ba/- 1.6V P-P square wave. Rise time approximately 35us 

          Connector 

Male XLR-3,  1=GND, 2=TC+, 3=TC- 

 

Figure 7-1,  Balanced Time Code XLR-3 Pin Connections 

 
Frame Rates 

 

 

TCG 

Generates time code at 23.976, 24, 25, 29.97DF, 29.97NDF, and 30 FPS 

    Video/TCR Genlock 

+/-1 TCG bit time maximum 

    1PPS Genlock 

Frame 00 +/-2.5ms maximum 

    Free-run Stability 

Maximum drift of +/- 1-frame-per-hour over operating temperature range 

 
  TCR 

Reads  23.976,  24,  25,  29.97DF,  29,97NDF,  and  30  FPS  SMPTE  Longitudinal  time 

     

code from approximately 1/10 play speed up too 10X play speed. For TCG time code 

     

genlock the TCR reads time code at “play speed” +/- apprx. 15%. 

Summary of Contents for HOR-TRG-100

Page 1: ...th LED Display 23 976 24 25 29 97DF 29 97NDF and 30 FPS SD Video Compatible 50 720P 50 1080i 59 94 720P 59 94 1080i HD Tri Level Sync Compatible USER MANUAL Software Version TRG2 01 Doc 073164 00 Rev...

Page 2: ...form or by any means without prior written consent of HORITA Co Inc P O Box 3993 Mission Viejo CA 92690 HORITA Co makes no warranties with respect to this documentation and disclaims any warranties of...

Page 3: ...4 16 DF LED 8 4 17 Selecting Time Code User Bits or FPS for Display 8 4 18 TCR Operation 8 4 19 TCG Operation 8 4 20 Starting and Stopping the TCG Time Code 8 4 21 TCG Time Code Jam and Genlock Operat...

Page 4: ...PS display change TCG FPS rate start stop preset the generator select the genlock source etc Both balanced and un balanced time code inputs and outputs provide for quick hookup into different time cod...

Page 5: ...z AC power Note that you may also have been supplied with an equivalent power adapter for use with other mains supply voltages and for operation at 50 Hz AC power WARNING ELECTRICALLY OPERATED PRODUCT...

Page 6: ...the TRG 100 4 3 MODE Switch The MODE switch is a three position switch labeled TCR TCG SET The TCR and TCG positions select between the basic time code reader or time code generator functions The SET...

Page 7: ...d characters available using a 7 segment display hexadecimal characters A F are displayed as A b C d E F 4 10 FPS Display Format The FPS display shows the FPS rate of either the TCR or the TCG The fol...

Page 8: ...isplayed on the LED display UB selects the time code user bits value TC selects the time code time value and FPS selects the FPS rate of the time code The FPS display value is for the TCR if in TCR mo...

Page 9: ...nlocked to the jam source time code or to a video sync input to the TRG 100 Genlocked means phase locked and this in turn means that for example if the frame rates of the TRG 100 time code IN and time...

Page 10: ...ode Time code genlock works like this because although the TCR and TCG frame rates may not match for example if the TCR equals 25 FPS and the TCG equals 30 FPS because the jam operation occurred at th...

Page 11: ...hen alternately actuate and release it again to select a different digit to preset Repeat this action until the digit you desire to preset is flashing If no other action is taken the flashing will sto...

Page 12: ...the first preset value recalled after the 1 second delay is the last preset value that was used For example if PRE2 was used to preset the TCG then whenever the Preset cycle is started by again by hol...

Page 13: ...paragraph 1 2 5 2 SMPTE Time Code SMPTE time code is an electronic timing signal that assigns a unique number to identify each individual frame image of video or film SMPTE time code was initially de...

Page 14: ...utes It s just the numbers 00 and 01 of the time code that are skipped no actual frames are skipped or dropped This time code frame rate is also compatible with 59 94 FPS HD frame rate applications Th...

Page 15: ...en continue counting as normal This is called drop frame time code although no frames of anything are actually dropped So with drop frame time code at the start of each minute the frame count wraps fr...

Page 16: ...IN Level 200mV to 10V P P Connector RCA OUT Level 1 6V P P square wave Rise time approximately 35us Connector RCA Balanced Time Code IN Level Balanced 200mV to 10V P P square wave Connector Female XLR...

Page 17: ...FPS and 30 FPS Switches POWER ON OFF Toggle switch MODE COUNTK Momentary action toggle switch GENLOCK DISPLAY Toggle switch Environment Operating 5C to 40C 41F to 104F Storage 10C to 60C 14F to 140F...

Reviews: