How to replace Power Drive belt

Disconnect cleaner from electrical outlet before replacing belt.

To replace the (small) Power Drive belt it is necessary to first remove the

bottom plate, agitator and the larger agitator belt.

Note: 

It may not be necessary to change both belts at one time.

The Power Drive belt is replaced

by placing the belt around the
motor pulley first, then the drive
pulley.

Lettering on belt should be visible

and not against pulleys.

Replace the agitator belt and bot-

tom plate, following instruction
previously given.

18

Summary of Contents for Concept one

Page 1: ......

Page 2: ...to run in a stationary position on non carpeted floors damage could occur to these surfaces l Unplug cleaner when not in use Turn machine off at switch before unplugging l Always disconnect cord from...

Page 3: ...Cord reel model Make a small loop with cord and place it over the hook at the back of the handle When operating cord should be positioned as shown 7 Before operating your cleaner identify features an...

Page 4: ...Switch some models have two speeds 8 Manual Operation Button depress to disengage Power Drive fea ture in tight cleaning areas 9 Power Drive Handle Grip 10 Air Freshener Dispenser some models only des...

Page 5: ...er ON push switch down To turn cleaner OFF push switch up Some cleaners are equipped with a two speed switch When the switch is pushed up as far as pos sible it is in the OFF position LOW SPEED is to...

Page 6: ...er furniture set the cleaner switch on the LOW speed setting or depress the manual operation button to disengage the power drive mechinism Manual operation button For cleaning and maneuvering without...

Page 7: ...USH or SHAG When cleaning noti carpeted floors set adjustment lever to LOW MEDIUM and use LOW SPEED if available on your cleaner Because of the vigorous action of the agitator do not allow cleaner to...

Page 8: ...wer to insert projections into back of cap opening Push drawer down into position and hook bag spring Cleaning Tools This cleaner may be used with cleaning tool attachments Some models have a cleaning...

Page 9: ...connector This unit should remain assembled for all future tool use Using cleaning tools A Attach converter Disconnect cleaner from elec trical outlet Cleaner must not be plugged in when positioning o...

Page 10: ...d set only for dusting surfaces such as table tops lamp shades dra peries as well as for cleaning up holstered furniture stairs and au tomobile interiors 4 Dusting brush for carved fur niture table to...

Page 11: ...osition or to the HIGH position on some models To clean attachments To clean the hose wipe off dirt with a cloth dampened with a liq uid detergent Rinse with a damp cloth Cleaning tools may be washed...

Page 12: ...owing belt replacement for fluff accumulation Where to buy bags Bags may be purchased from your local Authorized Hoover Dealer or from a Hoover Factory Service Center When ordering bags be sure to giv...

Page 13: ...t 3 Push cardboard bag collar firmly onto fill tube by first positioning bottom of collar and then top onto tube Make sure the collar is pushed past the raised portion at the top and bottom and tightl...

Page 14: ...andle until the cleaner is positioned with the bag flat on the floor 2 Use screwdriver to lift lens Place screwdriver in the two slots provided at the top edge under ridge of lens as shown Turn screwd...

Page 15: ...en to replace belts Check from time to time to be sure the belts are in good condition If they are stretched cut or broken they should be replaced How to replace agitator belt Disconnect cleaner from...

Page 16: ...new belt over the metal motor pulley Lettering on belt should be visible and not against pulleys Slip the other end around the plastic pulley end of the agitator See illustration AGITATOR END PLATE 7...

Page 17: ...front of the bottom plate over the notched edge on the front of the cleaner 10 Press firmly to be sure agitator is securely in place 12 Maintaining front connection rotate bottom plate to cover bot to...

Page 18: ...the bottom plate agitator and the larger agitator belt Note It may not be necessary to change both belts at one time The Power Drive belt is replaced by placing the belt around the motor pulley first...

Page 19: ...re easily cleaned out by the following methods Disconnect cleaner from electrical outlet For access to the dirt duct turn cleaner over to expose underside Remove bottom plate Lift dirt duct as shown a...

Page 20: ...ush to snap other side into posi tion Agitator brushes Disconnect cleaner from electri cal outlet before checking brushes When brushes are worn and bristles do not touch the edge of a card held across...

Page 21: ...y The word BAR is stamped near the slots on the agitator Match the bar side of the bar brush assembly with the label on the agitator shell Slide the new assemblies into the slots while twisting the as...

Page 22: ...ice Dealer where approved HOOVER service and genuine HOOVER replacement parts may be ob tained The warranty provided with this product has a listing of the Hoover Factory Service Centers If you are un...

Page 23: ...cord reel rewinding The use of an extension cord is not recommended Never vacuum in the presence of flammable or combustible liquids or fumes Always unplug power cord from wall outlet before servicing...