Honeywell WV8840A Installation Instructions Manual Download Page 3

WV8840A WATER HEATER CONTROLS

3

69-2247—05

WARNING

Fire or Explosion Hazard.

Can cause severe injury, death or property 

damage.

Follow these warnings exactly:

1. To avoid dangerous accumulation of fuel gas, 

turn off gas supply at the appliance service valve 

before starting installation and perform the Gas 

Leak Test after completion of installation.

2. Always install a sediment trap in gas supply line 

to prevent contamination of ignition system 

control.

3. Follow the appliance manufacturer instructions 

if available; otherwise, use these instructions as 

a guide.

WARNING

Scalding Hazard.

Can cause burns, severe injury or death.

Always use a direct replacement sensor assembly 

when replacing a temperature sensor.

Location

The WV8840A is mounted on the outside of the water 

heater tank. See Fig. 2.

Fig. 2. Mounting the WV8840A on the water heater 

tank.

Install Control to Water Tank

1.

To install the water heater control, screw the assem-

bly into spud until the bracket is square. Use a max-

imum torque of 31 ft.-lbs. plus one turn.

2.

Follow steps in the Connect Gas Supply section.

IMPORTANT

These water heater system controls are shipped 

with protection for the inlet and outlet tappings. 

Do not remove the protection until you are ready 

to connect the piping.

Connect Gas Supply

All piping must comply with local codes and ordinances or 

with the National Fuel Gas Code (ANSI Z223.1 NFPA No. 

54), whichever applies. Tubing installation must comply 

with approved standards and practices.

1.

Use a new, properly reamed pipe free from chips. If 

tubing is used, make sure the ends are square, 

deburred and clean. All tubing bends must be 

smooth and without deformation.

2.

Ensure that gas supply is turned off.

3.

Run pipe or tubing to the water heater control. If 

tubing is used, obtain a tube-to-pipe coupling to 

connect the tubing to the control.

4.

Install a sediment trap in the supply line to the water 

heater control. See Fig. 3.

Fig. 3. Install a sediment trap in the supply line.

WARNING

Explosion Hazard.

Can cause severe injury, death or property 

damage.

Check for gas leaks with soap and water solution 

any time work is done on a gas system.

5.

Apply a moderate amount of good quality pipe com-

pound, leave two end threads bare. Do not use pipe 

dope on the outlet. See Fig. 4

6.

Remove the seals over the water heater control inlet 

and outlet, if necessary.

7.

Connect the pipe to the water heater control inlet 

and outlet. Use a wrench on the square end of the 

water heater control. Maximum torque on the inlet is 

40 ft-lbs.; maximum torque on the outlet is 30 ft-lbs.

8.

Position compression fitting in pilot outlet and 

engage threads. See Fig. 5 for controls and connec-

tions. Turn until finger tight, then tighten one more 

turn with a wrench. Do not overtighten.

MOUNTING

WELL ASSEMBLY

ACCESS TO TANK

M29521

WV8840

HORIZONTAL 

DROP 

PIPED

GAS

SUPPLY

3 IN. 

(76 MM) 

MINIMUM 

TUBING

GAS

SUPPLY

HORIZONTAL

DROP

3 IN. 

(76 MM) 

MINIMUM 

RISER 

M29522

1

1

WARNING

EXPLOSION HAZARD. 

FAILURE TO FOLLOW PRECAUTIONS CAN 

RESULT  IN A GAS-FILLED WORK AREA.

SHUT OFF THE MAIN GAS SUPPLY BEFORE REMOVING END CAP.  

TEST FOR GAS LEAKAGE WHEN INSTALLATION IS COMPLETE.

ALL BENDS IN METALLIC TUBING SHOULD BE SMOOTH.

Summary of Contents for WV8840A

Page 1: ... is shown on the product label Inlet Pressure Range See appliance rating plate for inlet pressure range recommendation 1 2 PSI 14 0 in w c maximum inlet pressure allowed for proper operation Body Pattern 90 degrees with 1 2 in inlet and 1 2 in inverted flare outlet Mounting Mounting in upright position only Control Input Voltage Minimum 350 mV dc open circuit Voltage Maximum 850 mV dc open circuit...

Page 2: ...l or agricultural applications protect the control with a cover Dust or Grease Accumulation Heavy accumulations of dust or grease can cause the control to malfunction Where dust or grease can be a problem provide covers for the control to limit contamination Heat Excessively high temperature can damage the control Make sure the maximum ambient temperature at the control does not exceed the rating ...

Page 3: ...1 Use a new properly reamed pipe free from chips If tubing is used make sure the ends are square deburred and clean All tubing bends must be smooth and without deformation 2 Ensure that gas supply is turned off 3 Run pipe or tubing to the water heater control If tubing is used obtain a tube to pipe coupling to connect the tubing to the control 4 Install a sediment trap in the supply line to the wa...

Page 4: ...t of 1 2 in pipe with 5 in w c pressure 2 Depress the piezo igniter to light the pilot flame and hold the knob in until the status indicator starts to blink approximately 30 seconds indicating pilot now being held by electronics NOTE LED should blink once every three seconds If not check the error codes in Table 3 3 Release the knob and turn to the desired temperature setting The burner will come ...

Page 5: ...ow rate 1 Check the full rate manifold pressure listed on the appliance nameplate Water heater control full rate outlet pressure should match this rating 2 With burner operating check the water heater control flow rate using the meter clocking method or check pressure using a manometer connected to the outlet pressure tap on the water heater control See Fig 5 MAINTENANCE WARNING Fire or Explosion ...

Page 6: ...ronics is holding the Pilot Valve open and the Main Valve closed You can now turn the knob to a desired setpoint temperature LED will continue to flash 1 time every 3 seconds while in Idle mode no call for heat Strobe every 3 seconds Not an error indicates call for heat during normal operation Main valve open None Action required 2 flashes Low thermopile voltage main valve not turned ON Check ther...

Page 7: ...ed in event of any physical damage tampering bent terminals missing or broken parts stripped threads or evidence of exposure to heat WARNING Scalding Hazard Can cause burns severe injury or death Never move temperature setpoint knob past the HOT setting without checking water temperature at the faucet and readjusting until comfortably warm to the touch Consider the ages and health of all who will ...

Page 8: ...bove the previous temperature follow these instructions 1 Set the temperature setpoint knob to OFF 2 Turn off the main gas valve to the appliance 3 Wait five minutes to clear out any unburned gas If you then smell gas STOP Follow step 1 in the warning above If you DO NOT smell gas continue with the next step 4 Turn on the gas supply to the appliance 5 Restart the appliance by performing lighting p...

Reviews: