background image

™ 

Vuquest™ 3310g

Area-Imaging Scanner

User’s Guide

Summary of Contents for Vuquest 3310g

Page 1: ... Vuquest 3310g Area Imaging Scanner User s Guide ...

Page 2: ...s are reserved No part of this document may be photocopied repro duced or translated into another language without the prior written consent of HII 2011 2013 Honeywell International Inc All rights reserved Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners Web Address www honeywellaid...

Page 3: ...o correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or television technician for help If necessary the user should consult the dealer ...

Page 4: ...ompris le brouillage pouvant causer un fonctionnement indésirable C UL Statement C UL listed CSA C22 2 No 60950 1 07 2nd Edition Europe The CE marking indicates compliance to 2004 108 EC EMC Directive with Standards EN55022 CLASS B EN55024 EN61000 3 2 EN61000 3 3 In addition complies to 2006 95 EC Low Voltage Direc tive when shipped with recommended power supply European Contact Hand Held Products...

Page 5: ...ve been tested and classified as EXEMPT RISK GROUP to the standard IEC 62471 2006 CB Scheme Certified to CB Scheme IEC 60950 1 Second Edition Patents For patent information please refer to www honeywellaidc com patents Solids and Water Protection The Vuquest 3310 has a rating of IP53 immunity of foreign particles and drip ping water Warning To reduce the possibility of heat related injuries avoid ...

Page 6: ...h standards when not powering the imager with the optional power supply the power source should be listed and meet applicable requirements for a limited power source or a Class 2 power supply with rating 5 5 2 Vdc 1 0 A minimum ...

Page 7: ...Required Safety Labels Scanner Compliance Label location Part Number Serial Number and Revision Information location Illumination output ...

Page 8: ......

Page 9: ...ce Plug and Play 2 1 Keyboard Wedge 2 1 Laptop Direct Connect 2 1 RS232 Serial Port 2 2 USB IBM SurePos 2 2 USB PC or Macintosh Keyboard 2 3 USB HID 2 3 USB Serial 2 3 Remote MasterMind for USB 2 4 Verifone Ruby Terminal Default Settings 2 5 Gilbarco Terminal Default Settings 2 5 Honeywell Bioptic Aux Port Configuration 2 6 Datalogic Magellan Aux Port Configuration 2 6 NCR Bioptic Aux Port Configu...

Page 10: ... 26 Scanner Bioptic ACK NAK Timeout 2 26 Chapter 3 Input Output Settings Power Up Beeper 3 1 Beep on BEL Character 3 1 Trigger Click 3 1 Good Read and Error Indicators 3 2 Beeper Good Read 3 2 Beeper Volume Good Read 3 2 Beeper Pitch Good Read 3 3 Beeper Pitch Error 3 3 Beeper Duration Good Read 3 3 LED Good Read 3 4 Number of Beeps Good Read 3 4 Number of Beeps Error 3 4 Good Read Delay 3 5 User ...

Page 11: ...aracter Activation Timeout 3 15 Deactivation Character 3 15 Reread Delay 3 15 User Specified Reread Delay 3 16 2D Reread Delay 3 16 Illumination Lights 3 17 Aimer Delay 3 18 User Specified Aimer Delay 3 18 Aimer Mode 3 18 Centering 3 19 Preferred Symbology 3 21 High Priority Symbology 3 22 Low Priority Symbology 3 22 Preferred Symbology Time out 3 22 Preferred Symbology Default 3 23 Output Sequenc...

Page 12: ...ntercharacter Interfunction and Intermessage Delays 4 5 Intercharacter Delay 4 5 User Specified Intercharacter Delay 4 6 Interfunction Delay 4 6 Intermessage Delay 4 7 Chapter 5 Data Formatting Data Format Editor Introduction 5 1 Add a Data Format 5 1 Other Programming Selections 5 3 Terminal ID Table 5 4 Data Format Editor Commands 5 4 Move Commands 5 9 Search Commands 5 10 Miscellaneous Commands...

Page 13: ...ngth Description 7 2 Codabar 7 3 Codabar Concatenation 7 4 Code 39 7 6 Code 32 Pharmaceutical PARAF 7 8 Full ASCII 7 9 Code 39 Code Page 7 9 Interleaved 2 of 5 7 10 NEC 2 of 5 7 12 Code 93 7 14 Code 93 Code Page 7 15 Straight 2 of 5 Industrial three bar start stop 7 16 Straight 2 of 5 IATA two bar start stop 7 17 Matrix 2 of 5 7 18 Code 11 7 19 Code 128 7 20 ISBT 128 Concatenation 7 20 Code 128 Co...

Page 14: ...F417 7 44 MacroPDF417 7 45 MicroPDF417 7 45 GS1 Composite Codes 7 46 UPC EAN Version 7 46 GS1 Emulation 7 47 TCIF Linked Code 39 TLC39 7 48 QR Code 7 49 QR Code Page 7 50 Data Matrix 7 51 Data Matrix Code Page 7 51 MaxiCode 7 52 Aztec Code 7 53 Aztec Code Page 7 54 Chinese Sensible Han Xin Code 7 55 Postal Codes 2D 7 56 Single 2D Postal Codes 7 56 Combination 2D Postal Codes 7 57 Postal Codes Line...

Page 15: ... 1 Supported Interface Keys 9 3 Chapter 10 Utilities To Add a Test Code I D Prefix to All Symbologies 10 1 Show Decoder Revision 10 1 Show Scan Driver Revision 10 1 Show Software Revision 10 1 Show Data Format 10 2 Test Menu 10 2 TotalFreedom 10 2 Application Plug Ins Apps 10 3 EZConfig Scanning Introduction 10 3 Installing EZConfig Scanning from the Web 10 4 Resetting the Factory Defaults 10 5 Ch...

Page 16: ...l Output 12 6 USB 12 7 Chapter 13 Maintenance Repairs 13 1 Maintenance 13 1 Cleaning the Scanner 13 1 Cleaning the Window 13 1 Inspecting Cords and Connectors 13 2 Replacing Cables 13 2 Replacing an Interface Cable 13 2 Troubleshooting a Corded Scanner 13 2 Chapter 14 Customer Support Appendix A Reference Charts Symbology Charts A 1 Linear Symbologies A 1 2D Symbologies A 3 Postal Symbologies A 3 ...

Page 17: ...ix Unicode Key Maps A 13 ...

Page 18: ...x ...

Page 19: ... by scanning the bar codes in this guide An asterisk next to an option indicates the default setting Unpacking Your Device After you open the shipping carton containing the product take the following steps Check for damage during shipment Report damage immediately to the carrier who delivered the carton Make sure the items in the carton match your order Save the shipping container for later storag...

Page 20: ... provides data output that is similar to keyboard entries The following is an example of a keyboard wedge connection 1 Turn off power and disconnect the keyboard cable from the back of the terminal computer 2 Connect the appropriate interface cable to the device and to the terminal computer 3 Turn the terminal computer power back on The scanner beeps 4 Verify the scanner operation by scanning a ba...

Page 21: ...ector into the serial port on your computer Tighten the two screws to secure the connector to the port 4 Once the scanner has been fully connected power up the computer This interface programs 115 200 baud 8 data bits no parity and 1 stop bit Note Please note the end of the cable with the ferrite plugs into the scanner The end of the cable with the label DO NOT connect this end to the bar code sca...

Page 22: ...ther from the unit To read single or multiple symbols on a page or on an object hold the scanner at an appropriate dis tance from the target press the button and center the aiming beam on the sym bol If the code being scanned is highly reflective e g laminated it may be necessary to tilt the code up 15 to 18 to prevent unwanted reflection Menu Bar Code Security Settings Honeywell scanners are prog...

Page 23: ...usly saved the setting for Beeper Volume at Low to your custom defaults and decide you want the beeper volume set to High just scan the Set Custom Defaults bar code then scan the Beeper Volume High menu code and then Save Custom Defaults The rest of the custom defaults will remain but the beeper volume setting will be updated Resetting the Custom Defaults If you want the custom default settings re...

Page 24: ...1 6 ...

Page 25: ...grammed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard scan the bar code below Keyboard wedge is the default interface Note The following bar code also programs a carriage return CR suffix Laptop Direct Connect For most laptops scanning the Laptop Direct Connect bar code allows operation of the scanner in parallel with the integral keyboard The follow ing Laptop Dire...

Page 26: ...r for an IBM SurePos USB handheld scanner or IBM SurePos USB tabletop scanner interface Note After scanning one of these codes you must power cycle the cash register Each bar code above also programs the following suffixes for each symbol ogy Option Setting Baud Rate 115 200 bps Data Format 8 data bits no parity bit 1 stop bit Symbology Suffix Symbology Suffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 I...

Page 27: ... program the scanner to emulate a regular RS232 based COM Port If you are using a Microsoft Windows PC you will need to download a driver from the Honeywell website www honeywellaidc com The driver will use the next available COM Port number Apple Macintosh computers recognize the scanner as a USB CDC class device and automatically use a class driver Note No extra configuration e g baud rate is ne...

Page 28: ... wish to configure your scanner to communicate with Remote MasterMind Scanner Management Software ReM Scan the ReM On bar code to communicate with ReM To disable this capability scan ReM Off Default ReM On CTS RTS Emulation On CTS RTS Emulation Off ACK NAK Mode On ACK NAK Mode Off ReM Off ReM On ...

Page 29: ...n scan the programming code above Gilbarco Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Gil barco terminal This bar code sets the baud rate to 2400 bps and the data format to 7 data bits even parity 2 stop bits It also adds a carriage return CR suffix and programs the following prefixes for each symbology Note If you are having unexpected results wit...

Page 30: ... configuration This bar code sets the baud rate to 9600 bps and the data format to 8 data bits no parity 1 stop bit Note If you are having unexpected results with this programming code scan the Activate Defaults bar code on page 1 5 first then scan the programming code above NCR Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for an NCR bioptic scanner a...

Page 31: ... Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf terminal This bar code sets the baud rate to 9600 bps and the data format to 8 data bits no parity 1 stop bit Note If you are having unexpected results with this programming code scan the Activate Defaults bar code on page 1 5 first then scan the programming code above NCR Bioptic Settings Wincor Nixdorf Terminal Se...

Page 32: ...The following prefixes are programmed for each symbology Note If you are having unexpected results with this programming code scan the Activate Defaults bar code on page 1 5 first then scan the programming code above Symbology Prefix Symbology Prefix Code 128 K EAN 13 A Code 93 L GS1 128 P Codabar N Interleaved 2 of 5 I UPC A A0 Straight 2 of 5 IATA H UPC E C All other bar codes M EAN 8 B Wincor N...

Page 33: ... or language As a general rule the following characters are sup ported but need special care for countries other than the United States United States United States Dvorak left United States International Albania Azeri Cyrillic Azeri Latin Belarus Belgium United States Dvorak United States Dvorak right Bosnia Brazil ...

Page 34: ...eyboard Country continued Bulgaria Latin Canada French Canada Multilingual Croatia Czech Czech Programmers Czech QWERTY Czech QWERTZ Bulgaria Cyrillic Canada French legacy Brazil MS Denmark Dutch Netherlands ...

Page 35: ...2 11 Keyboard Country continued Finland Gaelic Germany Greek Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 Faeroese France Estonia Greek Latin Greek MS ...

Page 36: ...2 12 Keyboard Country continued Italian 142 Hungarian 101 key Iceland Irish Italy Japan ASCII Kazakh Kyrgyz Cyrillic Hebrew Hungary Greek Polytonic Latin America Latvia ...

Page 37: ...2 13 Keyboard Country continued Lithuania IBM Malta Mongolian Cyrillic Norway Poland Polish 214 Polish Programmers Portugal Lithuania Macedonia Latvia QWERTY Romania Russia ...

Page 38: ...2 14 Keyboard Country continued SCS Serbia Latin Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation Russian Typewriter Serbia Cyrillic Russian MS Sweden Switzerland French ...

Page 39: ...If you have used Keyboard Conversion settings they will override any of the following Key board Style settings Default Regular Turkey F Ukrainian United Kingdom United Stated Dvorak right United States Dvorak left United States Dvorak United States International Uzbek Cyrillic Tatar Turkey Q Switzerland German ...

Page 40: ...e tracks and reflects if you have Caps Lock on or off This selection can only be used with systems that have an LED that notes the Caps Lock sta tus AT keyboards Autocaps via NumLock bar code should be scanned in countries e g Ger many France where the Caps Lock key cannot be used to toggle Caps Lock The NumLock option works similarly to the regular Autocaps but uses the Num Lock key to retrieve t...

Page 41: ...board Style selections Note If your interface is a keyboard wedge first scan the menu code for Automatic Caps Lock page 2 16 Otherwise your output may not be as expected Default Keyboard Conversion Off Control Character Output This selection sends a text string instead of a control character For example when the control character for a carriage return is expected the output would display CR instea...

Page 42: ...mode and it does not support all keyboard country codes New users should use the Windows mode Refer to Keyboard Function Relationships page 9 1 for CTRL X Values Windows Mode Prefix Suffix Off The scanner sends key combinations for ASCII control characters for values 00 1F but it does not translate any prefix or suffix information Default Control X Mode Off Control Character Output On Control Char...

Page 43: ...nds numeric characters as if entered from a numeric keypad Default Off Automatic Direct Connect Mode This selection can be used if you have an IBM AT style terminal and the system is dropping characters Default Off Turbo Mode On Turbo Mode Off Numeric Keypad Mode On Numeric Keypad Mode Off Automatic Direct Connect Mode On Automatic Direct Connect Mode Off ...

Page 44: ...iers RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 115 200 300 600 1200 2400 4800 9600 19200 ...

Page 45: ...7F decimal text digits and punctuation select 7 data bits For applications that require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None 38400 57600 115 200 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd ...

Page 46: ...Parity Even 7 Data 2 Stop Parity None 7 Data 2 Stop Parity Odd 8 Data 1 Stop Parity Even 8 Data 1 Stop Parity None 8 Data 1 Stop Parity Odd 7 Data 1 Stop Parity Space 7 Data 2 Stop Parity Space 8 Data 1 Stop Parity Space ...

Page 47: ... cover of this manual then scanning Save The range is 0 to 300 seconds Default 0 seconds no time out always on RS232 Handshaking RS232 Handshaking allows control of data transmission from the scanner using software commands from the host device When RTS CTS is turned Off no data flow control is used Flow Control No Timeout The scanner asserts RTS when it has data to send and will wait indefinitely...

Page 48: ...the length of the delay you want to wait for CTS from the host Set the length in millisec onds for a timeout by scanning the bar code below then setting the time out from 1 5100 milliseconds by scanning digits from the inside back cover then scanning Save XON XOFF Standard ASCII control characters can be used to tell the scanner to start sending data XON XOFF On or to stop sending data XON XOFF Of...

Page 49: ...e last set of bar code data is retransmitted and the scanner waits for ACK NAK again Turn on the ACK NAK protocol by scanning the ACK NAK On bar code below To turn off the protocol scan ACK NAK Off Default ACK NAK Off Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scanners and bioptic scanners Note The scanner s baud rate must be set to 3...

Page 50: ... is sent The Scan ner Bioptic ACK NAK Timeout below controls how long the scanner will wait for a response Default Bioptic ACK NAK Off Scanner Bioptic ACK NAK Timeout This allows you to set the length in milliseconds for a timeout for a bioptic scanner s ACK NAK response Scan the bar code below then set the tim eout from 1 30 000 milliseconds by scanning digits from the inside back cover then scan...

Page 51: ...BEL On bar code below the scanner will beep every time a BEL character is received from the host Default Beep on BEL Off Trigger Click To hear an audible click every time the scanner button is pressed scan the Trig ger Click On bar code below Scan the Trigger Click Off code if you don t wish to hear the click This feature has no effect on serial or automatic trigger ing Default Trigger Click Off P...

Page 52: ...is option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default Beeper Good Read On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default High Beeper Good Read On Beeper Good Read Off High Medium Off Low ...

Page 53: ...per pitch codes modify the pitch frequency of the sound the scan ner emits when there is a bad read or error Default Razz Beeper Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal Low 1600 Hz Medium 2700 Hz High 4200 Hz Razz 250 Hz Medium 3250 Hz High 4200 Hz Normal Beep Short Beep Short Beep ...

Page 54: ...r code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Number of Beeps Error The number of beeps and LED flashes emitted by the scanner for a bad read or error can be programmed from 1 9 For example if you program this option to have five error beeps there will be five error beeps and five LED flashes in respons...

Page 55: ...y scanning digits from the inside back cover then scanning Save Manual Trigger Modes When in manual trigger mode the scanner scans until a bar code is read or until the button is released Two modes are available Normal and Enhanced Normal mode offers good scan speed and the longest working ranges depth of field Enhanced mode will give you the highest possible scan speed but slightly No Delay Short...

Page 56: ...r the scanner when the but ton is pressed Default High Note The LEDs are like a flash on a camera The lower the ambient light in the room the brighter the LEDs need to be so the scanner can see the bar codes Serial Trigger Mode You can activate the scanner either by pressing the button or using a serial trig ger command see Trigger Commands on page 11 4 When in serial mode the scanner scans until ...

Page 57: ...ime Out bar code set the time out duration from 0 300 000 milliseconds by scanning digits on the Programming Chart inside the back cover then scanning Save Default 30 000 ms Presentation Mode Presentation Mode uses ambient light and scanner illumination to detect bar codes When in Presentation Mode the LEDs remain dim until a bar code is presented to the scanner then the aimer turns on and the LED...

Page 58: ...6 Default High Note The LEDs are like a flash on a camera The lower the ambient light in the room the brighter the LEDs need to be so the scanner can see the bar codes Note LED Illumination Presentation Mode does not apply to Streaming Presentation Mode or Mobile Phone Read Mode Presentation LED Behavior after Decode When a scanner is in presentation mode the LEDs dim 30 seconds after a bar code i...

Page 59: ... sure the scanner reads only those bar codes intended by the user For instance if multiple codes are placed closely together Presentation Centering will insure that only the desired codes are read Note To adjust centering when the scanner is hand held see Centering page 3 19 If a bar code is not touched by a predefined window it will not be decoded or output by the scanner If Presentation Centerin...

Page 60: ...s through the centering window it will be read Bar Code 2 does not pass through the centering window so it will not be read Note A bar code needs only to be touched by the centering window in order to be read It does not need to pass completely through the centering window 0 Bar Code 1 Bar Code 2 10 20 30 40 50 60 70 80 90 100 100 90 80 70 60 50 40 30 20 10 0 ...

Page 61: ...On the button is used to allow decoded data to be transmit ted to the host system The scanner remains on scanning and decoding bar codes but the bar code data is not transmitted until the button is pressed When CodeGate is Off bar code data is transmitted when it is decoded Default CodeGate Off Out of Stand Left of Presentation Centering Window Top of Presentation Centering Window Right of Present...

Page 62: ... in Streaming Presentation Mode Mobile Phone Read Mode When this mode is selected your scanner is optimized to read bar codes from mobile phone or other LED displays However the speed of scanning printed bar codes may be slightly lower when this mode is enabled You can enable Mobile Phone Reading for either a hand held device or for a hands free pre sentation application Note To turn off Mobile Ph...

Page 63: ...aser Timeout page 3 14 the deactivation character is received see Deactivation Character on page 3 15 or a bar code is transmitted Scan the following On bar code to use character activation then use Activation Character following to select the character you will send from the host to start scanning Default Off Activation Character This sets the character used to trigger scanning when using Charact...

Page 64: ...scanning Scan the fol lowing On bar code to use character deactivation then use Deactivation Character following to select the character you will send from the host to termi nate scanning Default Off End Character Activation After Good Read After a bar code is successfully detected and read from the scanner the illumination can be programmed either to remain on and scanning or to turn off When End...

Page 65: ...o terminate scanning when using Character Deactivation Mode On the ASCII Conversion Chart Code Page 1252 page A 4 find the hex value that represents the character you want to use to terminate scanning Scan the following bar code then use the Programming Chart to read the alphanumeric combination that represents that ASCII character Scan Save to finish Reread Delay This sets the time period before ...

Page 66: ...5 milliseconds by scanning digits from the inside back cover then scanning Save 2D Reread Delay Sometimes 2D bar codes can take longer to read than other bar codes If you wish to set a separate Reread Delay for 2D bar codes scan one of the program ming codes that follows 2D Reread Delay Off indicates that the time set for Reread Delay is used for both 1D and 2D bar codes Default 2D Reread Delay Of...

Page 67: ...ights On bar code below However if you want to turn just the lights off scan the Lights Off bar code Default Lights On Note This setting does not affect the aimer light The aiming light can be set using Aimer Mode page 3 18 Short 1000ms Medium 2000ms Long 3000ms Extra Long 4000ms Lights Off Lights On ...

Page 68: ... over Default Off User Specified Aimer Delay If you want to set your own length for the duration of the delay scan the bar code below then set the time out by scanning digits 0 4 000 ms from the Programming Chart inside the back cover of this manual then scan Save Aimer Mode This feature allows you to turn the aimer on and off When the Interlaced bar code is scanned the aimer is interlaced with th...

Page 69: ...re multiple codes are spaced closely together Using the Aimer Delay and Center ing features the scanner can emulate the operation of older systems such as linear laser bar code scanners Note To adjust centering when the scanner is in Presentation Mode see Presentation Centering page 3 9 If a bar code is not touched by a predefined window it will not be decoded or output by the scanner If Centering...

Page 70: ...s through the centering window it will be read Bar Code 2 does not pass through the centering window so it will not be read Note A bar code needs only to be touched by the centering window in order to be read It does not need to pass completely through the centering window 0 Bar Code 1 Bar Code 2 10 20 30 40 50 60 70 80 90 100 100 90 80 70 60 50 40 30 20 10 0 ...

Page 71: ...he PDF417 symbol you can use Preferred Symbology to specify that the PDF417 symbol be read instead of the Code 39 Preferred Symbology classifies each symbology as high priority low priority or as an unspecified type When a low priority symbology is presented the scanner ignores it for a set period of time see Preferred Symbology Time out on page 3 22 while it searches for the high priority symbolo...

Page 72: ...mbology Charts on page A 1 find the symbology you want to set as low priority Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside back cover If you want to set additional low priority symbologies scan FF then scan the 2 digit hex value from the Programming Chart for the next symbology You can program up to 5 low priority symbologies Scan Save to...

Page 73: ... want to delete or clear all formats before you read the Default Sequence symbol Note To make Output Sequence Editor selections you ll need to know the code I D code length and character match es your application requires Use the Alphanumeric symbols inside back cover to read these options You must hold the button while reading each bar code in the sequence To Add an Output Sequence 1 Scan the Ent...

Page 74: ...tor Scan F F to enter an Output Sequence for an additional symbology or Save to save your entries Other Programming Selections Discard This exits without saving any Output Sequence changes Output Sequence Example In this example you are scanning Code 93 Code 128 and Code 39 bar codes but you want the scanner to output Code 39 1st Code 128 2nd and Code 93 3rd as shown below Note Code 93 must be ena...

Page 75: ...ength If you use the example on page 3 24 but assume a CR suffix and specific code lengths you would use the following command line SEQBLK62001241FF6A001342FF69001243FF The breakdown of the command line is shown below SEQBLKsequence editor start command 62 code identifier for Code 39 0012 A Code 39 sample length 11 plus CR suffix 1 12 41 start character match for Code 39 41h A FF termination strin...

Page 76: ...o transmit partial sequences Any fields in the sequence where no data match occurred will be skipped in the output Require Output Sequence When an output sequence is Required all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device When it s On Not Required the scanner will attempt to get the output data to conform to an edited sequence...

Page 77: ... allows you to read multiple symbols with a single press of the scanner s button If you press and hold the button aiming the scanner at a series of symbols it reads unique symbols once beeping if turned on for each read The scanner attempts to find and decode new symbols as long as the button is pressed When this programming selection is turned Off the scanner will only read the symbol closest to ...

Page 78: ...everse Video Reverse is used to allow the scanner to read bar codes that are inverted The Video Reverse Off bar code below is an example of this type of bar code Scan Video Reverse Only to read only inverted bar codes Scan Video Reverse and Standard Bar Codes to read both types of codes Note After scanning Video Reverse Only menu bar codes cannot be read You must scan Video Reverse Off or Video Re...

Page 79: ...ideways or upside down Use the working orientation settings if your direction sensitive codes will not usually be presented upright to the scanner Default Upright Upright Vertical Top to Bottom Rotate CW 90 Upside Down Vertical Bottom to Top Rotate CCW 90 Upright Upside Down Vertical Top to Bottom Vertical Bottom to Top ...

Page 80: ...3 30 ...

Page 81: ...ault suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII Conversion Chart Code Page 1252 beginning on page A 4 plus Code I D and AIM I D You can string together several entries for several symbologies at one time Enter prefixes and suffixes in the order in which you want them to appear on the output When setti...

Page 82: ...thout saving Repeat Steps 1 6 to add a prefix or suffix for another symbology Example Add a Suffix to a specific symbology To send a CR carriage return Suffix for U P C only Step 1 Scan Add Suffix Step 2 Determine the 2 digit hex value from the Symbology Chart included in the Symbology Charts beginning on page A 1 for U P C Step 3 Scan 6 3 from the Programming Chart inside the back cover of this m...

Page 83: ...ue from the Programming Chart inside the back cover of this manual or scan 9 9 for all symbologies Your change is automatically saved To Add a Carriage Return Suffix to All Symbologies Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once This action first clears all current suffixes then pro grams a carriage return suffix for all symbologies Prefix Sel...

Page 84: ...code before it is transmitted Default Enable Communication Check Character To enhance security you can specify the transmission type of a check charac ter either LRC where the calculation starts on the first transmitted character LRC where the calculation starts on the second transmitted character or CRC Note This option adds a check character to the bar code data for all symbologies If you need t...

Page 85: ...ta increasing data integrity Intercharacter Delay An intercharacter delay of up to 5000 milliseconds in 5ms increments may be placed between the transmission of each character of scanned data Scan the Intercharacter Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual None LRC Starts on 1st Character LRC Star...

Page 86: ...r to Trigger Delay bar code then the 2 digit hex value for the ASCII character that will trigger the delay ASCII Conversion Chart Code Page 1252 beginning on page A 4 To remove this delay scan the Delay Length bar code and set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual Interfunction Delay An interfunction delay of up to 5000 mi...

Page 87: ...may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this man ual To remove this delay scan the Intermessage Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual 2nd Scan...

Page 88: ...4 8 ...

Page 89: ...Specific Terminal ID Universal Code ID Universal Length 5 Universal Terminal ID Actual Code ID Actual Length 6 Universal Terminal ID Actual Code ID Universal Length 7 Universal Terminal ID Universal Code ID Actual Length 8 Universal Terminal ID Universal Code ID Universal Length The maximum size of a data format configuration is 2000 bytes which includes header information If a bar code is read th...

Page 90: ...he Programming Chart inside the back cover of this manual If you wish to create a data format for all symbologies with the excep tion of some specific symbologies refer to B8 page 5 16 If you are creating a data format for Batch Mode Quantity use 35 for the Code I D Note 99 indicates all symbologies Step 5 Length Specify what length up to 9999 characters of data will be acceptable for this symbolo...

Page 91: ...epending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Charts on page A 1 and the bar code data length for the specific data format that you want to delete All other formats remain unaffected Clear all Data Formats This clears all data formats Save to exit and save your data format changes Discard to exit without saving any data format changes Enter Data Format S...

Page 92: ...end a number of characters F2 Include in the output message a number of characters followed by an insert character Start from the current cursor position and continue for nn characters or through the last character in the input message followed by character xx Syntax F2nnxx where nn stands for the numeric value 00 99 for the number of characters and xx stands for the insert character s hex value f...

Page 93: ... a CR The data is output as 1234567890 ABCDEFGHIJ CR Send all characters up to a particular character F3 Include in the output message all characters from the input message starting with the character at the current cursor position and continuing to but not including the search character ss followed by an insert character The cursor is moved forward to the ss character Syntax F3ssxx where ss stand...

Page 94: ... including AB Command string B900024142 B9 is the Send all characters up to a string command 0002 is the length of the string 2 characters 41 is the hex value for A 42 is the hex value for B The data is output as 1234567890 Send all but the last characters E9 Include in the output message all but the last nn characters starting from the current cursor position The cursor is moved forward to one po...

Page 95: ...ds for the length of the string and s s stands for the string The string is made up of hex values for the characters in the string Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 4 for decimal hex and character codes B9 and BA Example Look for the string AB and insert 2 asterisks Using the bar code above send all characters up to but not including AB Insert 2 asterisks at th...

Page 96: ...ic string and does not include leading zeroes B3 and B4 Example Insert the symbology name and length Send the symbology name and length before the bar code data from the bar code above Break up these insertions with spaces End with a carriage return Command string B3F42001B4F42001F10D B3 is the Insert symbology name command F4 is the Insert a character multiple times command 20 is the hex value fo...

Page 97: ...change from B5xxssnn for one keystroke to B5xxssnnssnnssnn An example that would insert abc is as follows B503001F00320030F833 Note Key modifiers can be added together when needed Example Control Left Shift Left 11 Move Commands Move the cursor forward a number of characters F5 Move the cursor ahead nn characters from current cursor position Syntax F5nn where nn is the numeric value 00 99 for the ...

Page 98: ... characters fol lowed by a carriage return Using the bar code above Command string FE31F7F2060D FE is the Compare characters command 31 is the hex value for 1 F7 is the Move the cursor to the beginning command F2 is the Send a number of characters command 06 is the number of characters to send 0D is the hex value for a CR The data is output as 123456 CR Move the cursor to the end EA Move the curso...

Page 99: ...2 beginning on page A 4 for decimal hex and character codes Search forward for a string B0 Search forward for s string from the current cursor position leaving cursor pointing to s string Syntax B0nnnnS where nnnn is the string length up to 9999 and S consists of the ASCII hex value of each character in the match string For example B0000454657374 will search forward for the first occurrence of the...

Page 100: ...alue for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 4 for decimal hex and character codes E6 Example Remove zeroes at the beginning of bar code data This example shows a bar code that has been zero filled You may want to ignore the zeroes and send all the data that follows E6 searches forward for the first character that is not zero then sends all the dat...

Page 101: ... above Command string FB0120F10D FB is the Suppress characters command 01 is the number of character types to be suppressed 20 is the hex value for a space F1 is the Send all characters command 0D is the hex value for a CR The data is output as 34567890 CR Stop suppressing characters FC Disables suppress filter and clear all suppressed characters Syntax FC Replace characters E4 Replaces up to 15 c...

Page 102: ... position Syntax FExx where xx stands for the comparison character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 4 for decimal hex and character codes Compare string B2 Compare the string in the input message to the string s If the strings are equal move the cursor forward past the end of the string Syntax B2nnnnS where nnnn is the string len...

Page 103: ...ar code begins with a letter If you want only data from bar codes that begin with a letter you can use ED to check for the letter Command string EDF10D ED is the Check for a non numeric character command F1 is the Send all characters command 0D is the hex value for a CR If this bar code is read the next data format if there is one will be used on this data If there is no other format the format fa...

Page 104: ...t as read including prefixes and suffixes You may wish to require the data to conform to a data format you have created and saved The following settings can be applied to your data format Data Formatter On Not Required Keep Prefix Suffix Scanned data is modified according to your data format and prefixes and suffixes are transmitted Data Formatter On Not Required Drop Prefix Suffix Scanned data is...

Page 105: ...canning bar codes without hearing the error tone If you scan the Data Format Non Match Error Tone Off bar code data that doesn t conform to your data format is not transmitted and no error tone will sound If you wish to hear the error tone when a non matching bar code is found scan the Data Format Non Match Error Tone On bar code Default Data Format Non Match Error Tone On Data Formatter On Not Re...

Page 106: ...d under 1 2 and 3 To set your device to use one of these formats scan one of the bar codes below Single Scan Data Format Change You can also switch between data formats for a single scan The next bar code is scanned using an alternate data format then reverts to the format you have selected above either Primary 1 2 or 3 Primary Data Format Data Format 1 Data Format 2 Data Format 3 ...

Page 107: ...witch to Data Format 1 for a single button press by scanning the Single Scan Data Format 1 bar code below The next bar code that is scanned uses Data Format 1 then reverts back to Data Format 3 Single Scan Data Format 1 Single Scan Data Format 2 Single Scan Data Format 3 Single Scan Primary Data Format ...

Page 108: ...5 20 ...

Page 109: ...detection from the third party device to trigger the scanner If you want to use the third party device object detection scan the External Trigger Control On bar code If you want to use the 3310 scanner object detection scan the External Trigger Control Off bar code Default External Trigger Control Off External Trigger Polarity External Trigger Polarity has two states High and Low A digital high po...

Page 110: ...Current Low Value 6 Milliamperes Input protection diode current The limiting factor on current is the dissipation in the 1KΩ 0402 resistor not the gate diode limit Parameter Values Input Resistance to Ground Low Value 9 7 KΩ Nominal Value 10 0 KΩ High Value 10 3 KΩ Pull down resistor loading Maximum Input Low Voltage Logical Low Level High Value 0 8 Volts Value does not include harness drops or ma...

Page 111: ...Example of Trigger Input Connection Using an Opto Isolator 5 2V AC Adapter N C 5 2V Scanner Power 5 2V Push pull logic gate or similar type driver Push pull logic gate or similar type driver Opto Isolator Scanner Cable with External Trigger and Lamp Signals Scanner Cable with External Trigger and Lamp Signals Note All connections for power and ground and communication not shown for clarity Additio...

Page 112: ...device to use exter nal illumination supplemental to the illumination from the scanner If the illumination will be provided by the third party device scan the External Illumination Control On bar code Default External Illumination Control Off External Illumination Control Off External Illumination Control On ...

Page 113: ...lue 5mA Maximum current limited by series resistor dissipation Parameter Values Output Low Voltage Iout 500uA High Value 0 6 Volts Internal one hundred ohm series resistor drop included Output Low Voltage Iout 1mA High Value 0 7 Volts Output Low Voltage Iout 4mA High Value 1 0 Volts Output Low Voltage Iout 6mA High Value 1 2 Volts Output High Voltage Iout 500uA Low Value 3 6 Volts Output High Volt...

Page 114: ...tate buffer or equivalent 10K Resistor 100 Ohm 0603 Resistor 4 9V to 5 2V Scanner Controller Pin 15 3310 Scanner Pin 6 Customer Device Power Link Not on all cables AC Adapter Customer Ground 5 2V Scanner Power 5 2V Scanner Cable with External Trigger and Lamp Signals Yellow Wire Pin 11 To Customer PC Register data connector Black Wire Lamp Driver Switch Customer Ground Please see External Illumina...

Page 115: ... Codablock F NEC 2 of 5 Code 11 Postal Codes 2D Code 128 Postal Codes Linear Code 32 Pharmaceutical PARAF PDF417 Code 39 GS1 DataBar Omnidirectional Code 93 QR Code Data Matrix Straight 2 of 5 IATA two bar start stop EAN JAN 13 Straight 2 of 5 Industrial three bar start stop EAN JAN 8 TCIF Linked Code 39 TLC39 GS1 Composite Codes Telepen GS1 DataBar Expanded Trioptic Code GS1 DataBar Limited UPC A...

Page 116: ... scanner will issue an error tone You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data This helps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15Max length 15 For a value o...

Page 117: ...rs are created using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 check characters Default No Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate and Transmit the scanner will only read Codabar bar codes printed with a check character ...

Page 118: ...nner looks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two mes sages are concatenated into one with the D characters omitted Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters No Check Character Validate...

Page 119: ...e bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Minimum Message Length Maximum Message Length ...

Page 120: ...Start Stop characters Default Don t Transmit Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data On Off Transmit Don t Tra...

Page 121: ...length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 0 48 Minimum Default 0 Maximum Default 48 Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer When the scanner encounters a Code 39 bar code with the append trigger char No Check Character Va...

Page 122: ...ransmitted in the order in which the bar codes were read FIFO Default Off Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical is a form of the Code 39 symbology used by Ital ian pharmacies This symbology is also known as PARAF Note Trioptic Code page 7 41 must be turned off while scanning Code 32 Pharmaceutical codes Off On Off On ...

Page 123: ...as created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D ...

Page 124: ...lt All Interleaved 2 of 5 Settings Interleaved 2 of 5 On Off Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit When Check Digit is set to Validate but Don t Transmit the unit only reads Interleaved 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data Code 39 Code Page On Off ...

Page 125: ...e scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Validate but Don t Transmit No Check Digit Validate and Transmit Minimum Message Length Maximum Message Length ...

Page 126: ...but Don t Transmit the unit only reads NEC 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads NEC 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit On Off No Check Digit Validate and Transmit Valida...

Page 127: ...the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Page 128: ...ault 0 Maximum Default 80 Code 93 Append This function allows the scanner to append the data from several Code 93 bar codes together before transmitting them to the host computer When this function is enabled the scanner stores those Code 93 bar codes that start with a space excluding the start and stop symbols and does not immediately transmit the data The scanner stores the data in the order in ...

Page 129: ...display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 10 and scan the value and the Save bar code from the Programming Chart o...

Page 130: ...of 5 Industrial On Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 131: ...f 5 IATA On Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Off On Minimum Message Length Maximum Message Length ...

Page 132: ...atrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off Maximum Message Length Minimum Message Length ...

Page 133: ...1 Default All Code 11 Settings Code 11 On Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes Default Two Check Digits On Off One Check Digit Two Check Digits ...

Page 134: ...enation In 1994 the International Society of Blood Transfusion ISBT ratified a standard for communicating critical blood information in a uniform manner The use of ISBT formats requires a paid license The ISBT 128 Application Specification describes 1 the critical data elements for labeling blood prod ucts 2 the current recommendation to use Code 128 due to its high degree of security and its spac...

Page 135: ... Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Code 128 Append This function allows the scanner to append the data from several Code 128 bar codes together before transmitting them to the host computer When the scanner encounters a Code 128 bar code with the append trigger char acter s it buffers Code 128 bar codes until it reads a Code 128 bar code that does not have the append trigge...

Page 136: ...ng a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 10 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly Code...

Page 137: ... Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 138: ...t stop pat tern 1 and decodes them as standard full ASCII start stop pattern 1 When Original Telepen Output is selected the scanner reads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output On Off Original Telepen Output AIM Telepen Output ...

Page 139: ...gth Description page 7 2 for additional information Mini mum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 UPC A Default All UPC A Settings UPC A On Off Note To convert UPC A bar codes to EAN 13 see Convert UPC A to EAN 13 on page 7 32 Minimum Message Length Maximum Message Length On Off ...

Page 140: ... system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda On Off Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Page 141: ...codes to enable or disable UPC A and EAN 13 with Extended Coupon Code When left on the default setting Off the scanner treats Cou pon Codes and Extended Coupon Codes as single bar codes If you scan the Allow Concatenation code when the scanner sees the coupon code and the extended coupon code in a single scan it transmits both as sepa rate symbologies Otherwise it transmits the first coupon code i...

Page 142: ...UPC and GS1 DataBar codes you may wish to scan and output only the data from the GS1 DataBar code Scan the GS1 Output On code below to scan and output only the GS1 DataBar code data Default GS1 Output Off Allow Concatenation Off Require Concatenation GS1 Output Off GS1 Output On ...

Page 143: ...th the 0 number system To read these codes use the UPC E0 On selection If you need to read codes that lead with the 1 number system use UPC E1 page 7 31 Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 On UPC E0 Off On Off ...

Page 144: ...0 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On Not Required Required Off On Off On ...

Page 145: ...r 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda UPC E1 Most U P C bar codes lead with the 0 number system For these codes use UPC E0 page 7 29 If you need to read codes that lead with the 1 number system use the UPC E1 On selection Default Off Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On UPC E1 On UPC E1 Off ...

Page 146: ...ert UPC A to EAN 13 When UPC A Converted to EAN 13 is selected UPC A bar codes are converted to 13 digit EAN 13 codes by adding a zero to the front When Do not Convert UPC A is selected UPC A codes are read as UPC A On Off Do not Convert UPC A UPC A Converted to EAN 13 ...

Page 147: ...enda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Addenda Required When Required is scanned the scanner will only read EAN JAN 13 bar codes that have addenda Default Not Required Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required ...

Page 148: ...om the addenda When turned Off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 7 27 ISBN Translate When On is scanned EAN 13 Bookland symbols are translated into their equivalent ISBN number format Default Off Off On Off On ...

Page 149: ... Default All EAN JAN 8 Settings EAN JAN 8 On Off EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off Off On ...

Page 150: ...red is scanned the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required Off On ...

Page 151: ...ogram the scanner to read MSI bar codes with Type 10 check characters Default Validate Type 10 but Don t Transmit When Check Character is set to Validate Type 10 11 and Transmit the scanner will only read MSI bar codes printed with the specified type check character s and will transmit the character s at the end of the scanned data On Off ...

Page 152: ... length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 10 and Transmit Validate Type 10 but Don t Transmit Validate 2 Type 10 Characters but Don t Transmit Validate 2 Type 10 Characters and Transmit Validate Type 10 then Type 11 Character but Don t Transmit Validate Type 10 then Type 11 Ch...

Page 153: ... DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off On Off On Off ...

Page 154: ...n Off GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 On Off Minimum Message Length Maximum Message Length ...

Page 155: ... If you are going to scan Code 32 Pharmaceutical codes page 7 8 Trioptic Code must be off Trioptic Code is used for labeling magnetic storage media Codablock A Default All Codablock A Settings Codablock A On Off On Off On Off ...

Page 156: ...the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 600 Minimum Default 1 Maximum Default 600 Minimum Message Length Maximum Message Length ...

Page 157: ...lock F Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 On Off Minimum Message Length Maximum Message Length ...

Page 158: ...sage Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 On Off Maximum Message Length Minimum Message Length ...

Page 159: ...capable of encoding very large amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a single data string Default On MicroPDF417 Default All MicroPDF417 Settings MicroPDF417 On Off On Off Off On ...

Page 160: ... for the co existence of symbologies already in use Default Off UPC EAN Version Scan the UPC EAN Version On bar code to decode GS1 Composite sym bols that have a U P C or an EAN linear component This does not affect GS1 Composite symbols with a GS1 128 or GS1 linear component Default UPC EAN Version Off Note If you scan coupons that have both UPC and GS1 DataBar codes you may wish to scan and outp...

Page 161: ...ize one data carrier type If GS1 128 Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Charts on page A 1 If GS1 DataBar Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 DataBar AIM ID em...

Page 162: ...d code component All bar code readers are capable of reading the Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off GS1 DataBar Emulation GS1 128 Emulation GS1 Emulation Off GS1 Code Expansion Off EAN8 to EAN13 Conversion Off On ...

Page 163: ...dditional information Mini mum and Maximum lengths 1 7089 Minimum Default 1 Maximum Default 7089 QR Code Append This function allows the scanner to append the data from several QR Code bar codes together before transmitting them to the host computer When the scanner encounters an QR Code bar code with the append trigger character s it buffers the number of QR Code bar codes determined by On Off Ma...

Page 164: ...er characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 10 and scan the value and the Save bar code from the Programming Chart on the inside the back...

Page 165: ...ata Matrix Code Page Data Matrix Code pages define the mapping of character codes to charac ters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created...

Page 166: ...ar properly MaxiCode Default All MaxiCode Settings MaxiCode On Off MaxiCode Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Data Matrix Code Page On Off Maximum Message Length Minimum Message Length ...

Page 167: ...e 7 2 for additional information Mini mum and Maximum lengths 1 3832 Minimum Default 1 Maximum Default 3832 Aztec Append This function allows the scanner to append the data from several Aztec bar codes together before transmitting them to the host computer When the scanner encounters an Aztec bar code with the append trigger charac Off On Maximum Message Length Minimum Message Length ...

Page 168: ...d does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 10 and scan the value and the Save bar code from the Programm...

Page 169: ...f Han Xin Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Off On Maximum Message Length Minimum Message Length ...

Page 170: ...an be active at a time If you scan a second 2D postal code selection the first selection is over written Default 2D Postal Codes Off Single 2D Postal Codes 2D Postal Codes Off Australian Post On Japanese Post On KIX Post On Planet Code On British Post On Also see Planet Code Check Digit page 7 59 Canadian Post On Intelligent Mail Bar Code On Postal 4i On ...

Page 171: ...7 59 Planet Code and Postnet On Postnet and Postal 4i On Postnet and Intelligent Mail Bar Code On Postal 4i and Intelligent Mail Bar Code On Planet Code and Postnet with B and B Fields On Postal 4i and Postnet with B and B Fields On Intelligent Mail Bar Code and Postnet with B and B Fields On InfoMail and British Post On ...

Page 172: ...Postnet with B and B Fields On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On Planet Code Postnet and Postal 4i On Planet Code Postnet and Intelligent Mail Bar Code On Planet Code and Intelligent Mail Bar Code On Planet Code and P...

Page 173: ...on controls what interpretation is applied to customer fields in Aus tralian 4 State symbols Bar Output lists the bar patterns in 0123 format Numeric N Table causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables Combination C and N Tables ...

Page 174: ... linear postal codes Any combination of linear postal code selections can be active at a time China Post Hong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings Numeric N Table Bar Output Alphanumeric C Table Combination C and N Tables ...

Page 175: ... 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxi mum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 176: ...tion page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxi mum Default 48 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data Default Don t Transmit On Off Minimum Message Length Maximum Message Length Don t Transmit Check Digit Transmit Check Digit ...

Page 177: ...and such as setting the Imaging Style to 1P and the Wait for Trigger to 1T you would enter IMGSNP1P1T Note After processing an image capture command IMGSNP or IMGBOX you must follow it with an IMGSHP command if you want to see it on your terminal To add a command to a sequence each new command is separated with a semicolon For example to add the Image Ship command to the above sequence you would e...

Page 178: ...P Photo Style default This mimics a simple digital camera and results in a visually optimized image 2P Manual Style This is an advanced style that should only be used by an experienced user It allows you the most freedom to set up the scanner and has no auto exposure B Beeper Causes a beep to sound after an image is snapped 0B No beep default 1B Sounds a beep when the image is captured T Wait for ...

Page 179: ...e time can increase dramatically due to the near absence of light Units are 127 microseconds Default 7874 nE Range 1 7874 G Gain Gain is used in Manual Style only 2P Like a volume control the gain modifier boosts the signal and multiplies the pixel value As you increase the gain the noise in an image is also amplified 1G No gain default 2G Medium gain 4G Heavy gain 8G Maximum gain Example of Expos...

Page 180: ...his sets the maximum number of frames the scanner should take to reach the D Delta for Acceptance Update Tries is only available when using Photo Style 1P Default 6 nU Range 0 10 Target Set Point Percentage Sets the target point for the light and dark values in the captured image A setting of 75 means 75 of the pixels are at or below the target white value and 25 of the pixels are above the target...

Page 181: ...t affect the image in memory Any number of modifiers may be appended to the IMGSHP command For example you can use the following command to snap and ship a bitmap image with gamma correction and docu ment image filtering IMGSNP IMGSHP8F75K26U IMGSHP Modifiers A Infinity Filter Enhances pictures taken from very long distances greater than 10 feet or 3m The Infinity Filter should not be used with IM...

Page 182: ... Compensation disabled default 1C Compensation enabled D Pixel Depth Indicates the number of bits per pixel in the transmitted image KIM or BMP format only 8D 8 bits per pixel grayscale image default 1D 1 bit per pixel black and white image Example of Compensation at 0C Example of Compensation at 1C ...

Page 183: ...e in the image 0E Don t sharpen image default 14E Apply edge sharpen for typical image ne Apply edge sharpen using strength n n 1 24 F File Format Indicates the desired format for the image 0F KIM format 1F TIFF binary 2F TIFF binary group 4 compressed 3F TIFF grayscale 4F Uncompressed binary upper left to lower right 1 pixel bit 0 padded end of line 5F Uncompressed grayscale upper left to lower r...

Page 184: ... Invert image is used to rotate the image around the X or Y axis 1ix Invert around the X axis flips picture upside down 1iy Invert around the Y axis flips picture left to right Example of Histogram Stretch at 0H Example of Histogram Stretch at 1H Example of image with Invert Image set to 1ix Example of image not inverted Example of image with Invert Image set to 1iy ...

Page 185: ...e 0ir Image as snapped rightside up default 1ir Rotate image 90 degrees to the right 2ir Rotate image 180 degrees upside down 3ir Rotate image 90 degrees to the left Example of Noise Reduction On 1if Example of Noise Reduction Off 0if Example of Image Rotate set to 0ir Example of Image Rotate set to 2ir Example of Image Rotate set to 1ir Example of Image Rotate set to 3ir ...

Page 186: ...ing for text images is 50K 0K Gamma correction off default 50K Apply gamma correction for brightening typical document image nK Apply gamma correction factor n n 0 1 000 L R T B M Image Cropping Note Image Cropping should not be used with IMGSHP Modifiers see page 8 5 Ships a window of the image by specifying the left right top and bottom pixel coordinates Device columns are numbered 0 through 127...

Page 187: ... the protocol used to send the data Hmodem which is an Xmodem 1K variant that has additional header infor mation and the format of the image data that is sent 0P None raw data 2P None default for USB 3P Hmodem compressed default for RS232 4P Hmodem S Pixel Ship Pixel Ship sizes an image in proportion to its original size It decimates the image by shipping only certain regularly spaced pixels For e...

Page 188: ... better JPEG compression than the standard E Edge Sharpen command see page 8 13 This filter also works well when shipping pure black and white images 1 bit per pixel The optimal setting is 26U 0U Document image filter off default 26U Apply document image filter for typical document image nU Apply document image filter using grayscale threshold n Use lower numbers when the image contrast is lower 1...

Page 189: ...tonal range of an image or key type A low key image has detail concentrated in the shadows a high key image has detail concentrated in the highlights and an average key image has detail concentrated in the midtones This modifier ships the histogram for an image 0W Don t ship histogram default 1W Ship histogram Example of Blur Image Off 0V Example of Blur Image On 1V Image used for histogram Histog...

Page 190: ... size of the signature area as well as specify how far the signature area is from the bar code vertically and horizontally You can also set the resolution and file format for the final output of the signature capture image Note IMGBOX commands can only be triggered by one of the following types of bar codes PDF417 Code 39 Code 128 Aztec Codabar and Interleaved 2 of 5 Once one of these symbologies ...

Page 191: ...the sig nature should be transferred as an image to the host To see this example align the aimer with the signature area not with the bar code then press the button Send the following IMGBOX command string after the button push Example IMGBOX245w37h55y Note Case is not important in the command string It is used here only for clarity The following image is captured The IMGBOX commands have many dif...

Page 192: ...ether it will be grayscale or black and white 8D 8 bits per pixel grayscale image default 1D 1 bit per pixel black and white image F File Format This option indicates the type of file format in which to save the image 0F KIM format 1F TIFF binary 2F TIFF binary group 4 compressed 3F TIFF grayscale 4F Uncompressed Binary 5F Uncompressed grayscale 6F JPEG image default 7F Outlined image Example of I...

Page 193: ...darker the image The optimal setting for text images is 50K 0K Gamma correction off default 50K Apply gamma correction for brightening typical document image nK Apply gamma correction factor n n 1 255 R Resolution of Signature Capture Area The resolution is the number of pixels that the scanner outputs per each minimum bar width The higher the value for R the higher the quality of the image but al...

Page 194: ...e Area The width of the signature capture area must be measured in inches divided by 01 In the example the width of the area to be captured is 2 4 inches resulting in a value of W 2 4 0 01 240 A value of 245 was used in the example to accommodate a slightly wider image area X Horizontal Bar Code Offset The horizontal bar code offset allows you to offset the horizontal center of the signature captu...

Page 195: ... of the signature capture area Negative numbers indicate that the signature cap ture is above the bar code and positive numbers indicate that the area is below the bar code Measurements are in multiples of the minimum bar width Example of Vertical Offset set to 7Y Example of Vertical Offset set to 65Y ...

Page 196: ...8 20 ...

Page 197: ... the scanner Refer to page 2 18 enable Control X Control ASCII Mode Function Code HEX ASCII Value Full ASCII CTRL X Mode NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS 1E US 1F _ ...

Page 198: ...ply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany à 6 Italy 6 Switzerland 6 United Kingdom 6 Denmark 8 9 6 Norway 8 9 6 Spain 6 ...

Page 199: ... 06 CTRL break CNTRL break BEL 07 CR Enter RETURN BS 08 Reserved APPLE make HT 09 Tab TAB LF 0A Reserved APPLE break VT 0B Tab TAB FF 0C Delete Del CR 0D CR Enter RETURN SO 0E Insert Ins Help SI 0F Escape ESC DLE 10 F11 F11 DC1 11 Home Home DC2 12 Print Prnt Scrn DC3 13 Back Space BACKSPACE DC4 14 Back Tab LSHIFT TAB NAK 15 F12 F12 SYN 16 F1 F1 ETB 17 F2 F2 CAN 18 F3 F3 EM 19 F4 F4 SUB 1A F5 F5 ES...

Page 200: ...9 4 ...

Page 201: ...symbologies This is a temporary setting that will be removed when the unit is power cycled Show Decoder Revision Scan the bar code below to output the decoder revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision The scan driver controls image capture Show Software Revision Scan the bar code below to output the current software revision unit serial num ber a...

Page 202: ...in addition the content of that program ming code is output to the terminal Note This feature should not be used during normal scanner operation TotalFreedom TotalFreedom is an open system architecture that makes it possible for you cre ate applications that reside on your scanner Decoding apps and Data Format ting apps can be created using TotalFreedom For further information about TotalFreedom g...

Page 203: ...and create and print programming bar codes Using EZConfig Scanning you can even save open the programming parame ters for a scanner This saved file can be e mailed or if required you can create a single bar code that contains all the customized programming parameters and mail or fax that bar code to any location Users in other locations can scan the bar code to load in the customized programming T...

Page 204: ... provides all the image related functions that a 2D Scanner can perform You can capture an image using the current settings and the image will be displayed in an image window Images captured from the scanner can be saved to files in different image formats You can modify the image settings and save the image settings to an INI file which can be loaded later to capture new images Imaging also lets ...

Page 205: ...ogramming options are in your scanner or you ve changed some options and want to restore the scanner to factory default set tings first scan the Remove Custom Defaults bar code then scan Activate Defaults This resets the scanner to the factory default settings The Menu Commands beginning on page 11 5 list the factory default settings for each of the commands indicated by an asterisk on the program...

Page 206: ...10 6 ...

Page 207: ...paces have been used for clarity only Prefix Name Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII characters SYN M CR ASCII 22 77 13 Tag A 3 character case insensitive field that identifies the desired menu command group For example all RS232 configuration settings are identified with a Tag of 232 SubTag A 3 character case insensitive field that identifies the desired menu c...

Page 208: ...e specific command identified by the Tag and SubTag fields Concatenation of Multiple Commands Multiple commands can be issued within one Prefix Storage sequence Only the Tag SubTag and Data fields must be repeated for each com mand in the sequence If additional commands are to be applied to the same Tag then the new command sequence is separated with a comma and only the SubTag and Data fields of ...

Page 209: ...t is the device s current setting for Codabar Coding Enable Enter cbrena Response CBRENA1 ACK This response indicates that the device s Codabar Coding Enable CBRENA is set to 1 or on Example What are the device s settings for all Codabar selections Enter cbr Response CBRENA1 ACK SSX0 ACK CK20 ACK CCT1 ACK MIN2 ACK MAX60 ACK DFT ACK This response indicates that the device s Codabar Coding Enable CB...

Page 210: ... until the serial time out has been reached see Read Time Out on page 3 7 for a description and the serial command on page 11 14 Resetting the Custom Defaults If you want the custom default settings restored to your scanner scan the Acti vate Custom Defaults bar code below This resets the scanner to the custom default settings If there are no custom defaults it will reset the scanner to the factor...

Page 211: ...board Wedge IBM PC AT and Compatibles with CR suffix PAP_AT 2 1 Laptop Direct Connect with CR suffix PAPLTD 2 1 RS232 Serial Port PAP232 2 2 Plug and Play Codes IBM SurePos USB IBM SurePos Handheld PAPSPH 2 2 USB IBM SurePos Tabletop PAPSPT 2 2 Plug and Play Codes USB USB Keyboard PC PAP124 2 3 USB Keyboard Mac PAP125 2 3 USB Japanese Keyboard PC TRMUSB134 2 3 USB HID PAP131 2 3 USB Serial TRMUSB1...

Page 212: ...le PAPBTL 2 7 Program Keyboard Country U S A KBDCTY0 2 9 Albania KBDCTY35 2 9 Azeri Cyrillic KBDCTY81 2 9 Azeri Latin KBDCTY80 2 9 Belarus KBDCTY82 2 9 Belgium KBDCTY1 2 9 Bosnia KBDCTY33 2 9 Brazil KBDCTY16 2 9 Brazil MS KBDCTY59 2 10 Bulgaria Cyrillic KBDCTY52 2 10 Bulgaria Latin KBDCTY53 2 10 Canada French legacy KBDCTY54 2 10 Canada French KBDCTY18 2 10 Canada Multilingual KBDCTY55 2 10 Croati...

Page 213: ...CTY64 2 11 Greek 220 KBDCTY61 2 11 Greek 319 Latin KBDCTY65 2 11 Greek 319 KBDCTY62 2 11 Greek Latin KBDCTY63 2 11 Greek MS KBDCTY66 2 11 Greek Polytonic KBDCTY60 2 12 Hebrew KBDCTY12 2 12 Hungarian 101 key KBDCTY50 2 12 Hungary KBDCTY19 2 12 Iceland KBDCTY75 2 12 Irish KBDCTY73 2 12 Italian 142 KBDCTY56 2 12 Italy KBDCTY5 2 12 Japan ASCII KBDCTY28 2 12 Kazakh KBDCTY78 2 12 Kyrgyz Cyrillic KBDCTY7...

Page 214: ... KBDCTY26 2 13 Russian MS KBDCTY67 2 14 Russian Typewriter KBDCTY68 2 14 SCS KBDCTY21 2 14 Serbia Cyrillic KBDCTY37 2 14 Serbia Latin KBDCTY36 2 14 Slovakia KBDCTY22 2 14 Slovakia QWERTY KBDCTY49 2 14 Slovakia QWERTZ KBDCTY48 2 14 Slovenia KBDCTY31 2 14 Spain KBDCTY10 2 14 Spanish variation KBDCTY51 2 14 Sweden KBDCTY23 2 14 Switzerland French KBDCTY29 2 14 Switzerland German KBDCTY6 2 15 Tatar KB...

Page 215: ...version Off KBDCNV0 2 17 Convert all Characters to Upper Case KBDCNV1 2 17 Convert all Characters to Lower Case KBDCNV2 2 17 Keyboard Style Regular KBDSTY0 2 16 Caps Lock KBDSTY1 2 16 Shift Lock KBDSTY2 2 16 Automatic Caps Lock KBDSTY6 2 16 Autocaps via NumLock KBDSTY7 2 16 Emulate External Keyboard KBDSTY5 2 17 Control Character Output Control Character Output Off KBDNPE0 2 18 Control Character O...

Page 216: ...ric Keypad Off KBDNPS0 2 19 Numeric Keypad On KBDNPS1 2 19 Auto Direct Connect Off KBDADC0 2 19 Auto Direct Connect On KBDADC1 2 19 Baud Rate 300 BPS 232BAD0 2 20 600 BPS 232BAD1 2 20 1200 BPS 232BAD2 2 20 2400 BPS 232BAD3 2 20 4800 BPS 232BAD4 2 20 9600 BPS 232BAD5 2 20 19200 BPS 232BAD6 2 20 38400 BPS 232BAD7 2 21 57600 BPS 232BAD8 2 21 115200 BPS 232BAD9 2 21 Selection Setting Indicates default...

Page 217: ... 1 Stop Parity Even 232WRD5 2 22 8 Data 1 Stop Parity None 232WRD2 2 22 8 Data 1 Stop Parity Odd 232WRD8 2 22 7 Data 1 Stop Parity Space 232WRD9 2 22 7 Data 2 Stop Parity Space 232WRD10 2 22 8 Data 1 Stop Parity Space 232WRD11 2 22 7 Data 1 Stop Parity Mark 232WRD12 2 23 7 Data 2 Stop Parity Mark 232WRD13 2 23 8 Data 1 Stop Parity Mark 232WRD14 2 23 RS232 Receiver Time out Range 0 300 seconds 232L...

Page 218: ...et Mode On 232PKT2 2 26 Scanner Bioptic ACK NAK Mode Bioptic ACK NAK Off 232NAK0 2 26 Bioptic ACK NAK On 232NAK1 2 26 Scanner Bioptic ACK NAK Timeout ACK NAK Timeout 5100 232DLK 2 26 Input Output Selections Power Up Beeper Power Up Beeper Off Scanner BEPPWR0 3 1 Power Up Beeper On Scanner BEPPWR1 3 1 Beep on BEL Character Beep on BEL On BELBEP1 3 1 Beep on BEL Off BELBEP0 3 1 Trigger Click On BEPT...

Page 219: ...0Hz BEPFQ24200 3 3 Beeper Duration Good Read Normal Beep BEPBIP0 3 3 Short Beep BEPBIP1 3 3 LED Good Read Off BEPLED0 3 4 On BEPLED1 3 4 Number of Beeps Error 1 BEPERR1 3 4 Range 1 9 BEPERR 3 4 Number of Beeps Good Read 1 BEPRPT1 3 4 Range 1 9 BEPRPT 3 4 Good Read Delay No Delay DLYGRD0 3 5 Short Delay 500 ms DLYGRD500 3 5 Medium Delay 1000 ms DLYGRD1000 3 5 Long Delay 1500 ms DLYGRD1500 3 5 User ...

Page 220: ...erial Trigger Mode Read Time Out 0 300 000 ms 30 000 TRGSTO 3 7 Presentation Presentation Mode PAPTPR 3 7 LED Illumination Presentation Mode Off PWRLDC0 3 8 Low PWRLDC100 3 8 High PWRLDC150 3 8 Presentation LED Behavior After Decode LEDs On TRGPCK1 3 8 LEDs Off TRGPCK0 3 8 Presentation Sensitivity Range 0 20 1 TRGPMS 3 9 Selection Setting Indicates default Serial Command Indicates a numeric entry ...

Page 221: ...tation Centering Window 60 PDCBOT 3 11 CodeGate CodeGate Off Out of Stand AOSCGD0 3 11 CodeGate On Out of Stand AOSCGD1 3 11 Streaming Presentation Streaming Presentation Mode Normal PAPSPN 3 12 Streaming Presentation Mode Enhanced PAPSPE 3 12 Mobile Phone Read Mode Hand Held Scanning Mobile Phone PAPHHC 3 12 Streaming Presentation Mobile Phone PAPSPC 3 12 Hands Free Time Out Range 0 300 000 ms TR...

Page 222: ... 3 14 Deactivation Character HSTDCH 3 15 Reread Delay Short 500 ms DLYRRD500 3 16 Medium 750 ms DLYRRD750 3 16 Long 1000 ms DLYRRD1000 3 16 Extra Long 2000 ms DLYRRD2000 3 15 User Specified Reread Delay Range 0 65 535 ms DLYRRD 3 16 Illumination Lights Lights On SCNLED1 3 17 Lights Off SCNLED0 3 17 Aimer Delay 200 milliseconds SCNDLY200 3 18 400 milliseconds SCNDLY400 3 18 Off no delay SCNDLY0 3 1...

Page 223: ...ow 40 DECLFT 3 21 Right of Centering Window 60 DECRGT 3 21 Top of Centering Window 40 DECTOP 3 21 Bottom of Centering Window 60 DECBOT 3 21 Preferred Symbology On PRFENA1 3 22 Off PRFENA0 3 22 High Priority Symbology PRFCOD 3 22 Low Priority Symbology PRFBLK 3 22 Preferred Symbology Timeout 500 Range 1 3000 PRFPTO 3 23 Preferred Symbology Default PRFDFT 3 23 Output Sequence Editor Enter Sequence S...

Page 224: ...ideo Reverse Off VIDREV0 3 28 Working Orientation Upright ROTATN0 3 29 Vertical Bottom to Top Rotate CCW 90 ROTATN1 3 29 Upside Down ROTATN2 3 29 Vertical Top to Bottom Rotate CW 90 ROTATN3 3 29 Prefix Suffix Selections Add CR Suffix to All Symbologies VSUFCR 4 3 Prefix Add Prefix PREBK2 4 3 Clear One Prefix PRECL2 4 3 Clear All Prefixes PRECA2 4 3 Suffix Add Suffix SUFBK2 4 4 Clear One Suffix SUF...

Page 225: ...Length 0 1000 5ms increments DLYCRX 4 6 Character to Trigger Delay DLY_XX 4 6 Interfunction Delay Range 0 1000 5ms increments DLYFNC 4 6 Intermessage Delay Range 0 1000 5ms increments DLYMSG 4 7 Data Formatter Selections Data Format Editor Default Data Format None DFMDF3 5 1 Enter Data Format DFMBK3 5 3 Clear One Data Format DFMCL3 5 3 Clear All Data Formats DFMCA3 5 3 Selection Setting Indicates ...

Page 226: ...mat Non Match Error Tone On DFMDEC0 5 17 Data Format Non Match Error Tone Off DFMDEC1 5 17 Primary Alternate Data Formats Primary Data Format ALTFNM0 5 18 Data Format 1 ALTFNM1 5 18 Data Format 2 ALTFNM2 5 18 Data Format 3 ALTFNM3 5 18 Single Scan Data Format Change Single Scan Primary Data Format VSAF_0 5 19 Single Scan Data Format 1 VSAF_1 5 19 Single Scan Data Format 2 VSAF_2 5 19 Single Scan D...

Page 227: ...ALLENA0 7 2 All Symbologies On ALLENA1 7 2 Codabar Default All Codabar Settings CBRDFT 7 3 Off CBRENA0 7 3 On CBRENA1 7 3 Codabar Start Stop Char Don t Transmit CBRSSX0 7 3 Transmit CBRSSX1 7 3 Codabar Check Char No Check Char CBRCK20 7 4 Validate But Don t Transmit CBRCK21 7 4 Validate and Transmit CBRCK22 7 4 Codabar Concatenation Off CBRCCT0 7 4 On CBRCCT1 7 4 Require CBRCCT2 7 4 Codabar Messag...

Page 228: ...imum 0 48 48 C39MAX 7 7 Code 39 Append Off C39APP0 7 8 On C39APP1 7 8 Code 32 Pharmaceutical PARAF Off C39B320 7 8 On C39B321 7 8 Code 39 Full ASCII Off C39ASC0 7 9 On C39ASC1 7 9 Code 39 Code Page C39DCP 7 10 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings I25DFT 7 10 Off I25ENA0 7 10 On I25ENA1 7 10 Interleaved 2 of 5 Check Digit No Check Char I25CK20 7 11 Validate But Don t Transmit ...

Page 229: ... 80 80 N25MAX 7 13 Code 93 Default All Code 93 Settings C93DFT 7 14 Off C93ENA0 7 14 On C93ENA1 7 16 Code 93 Message Length Minimum 0 80 0 C93MIN 7 14 Maximum 0 80 80 C93MAX 7 14 Code 93 Append On C93APP1 7 15 Off C93APP0 7 15 Code 93 Code Page Code 93 Code Page C93DCP 7 15 Straight 2 of 5 Industrial Default All Straight 2 of 5 Industrial Settings R25DFT 7 16 Off R25ENA0 7 16 On R25ENA1 7 16 Strai...

Page 230: ... 18 Maximum 1 80 80 X25MAX 7 18 Code 11 Default All Code 11 Settings C11DFT 7 19 Off C11ENA0 7 19 On C11ENA1 7 19 Code 11 Check Digits Required 1 Check Digit C11CK20 7 19 2 Check Digits C11CK21 7 19 Code 11 Message Length Minimum 1 80 4 C11MIN 7 20 Maximum 1 80 80 C11MAX 7 20 Code 128 Default All Code 128 Settings 128DFT 7 20 Off 128ENA0 7 20 On 128ENA1 7 20 ISBT Concatenation Off ISBENA0 7 21 On ...

Page 231: ...A1 7 24 Telepen Output AIM Telepen Output TELOLD0 7 24 Original Telepen Output TELOLD1 7 24 Telepen Message Length Minimum 1 60 1 TELMIN 7 25 Maximum 1 60 60 TELMAX 7 25 UPC A Default All UPC A Settings UPADFT 7 25 Off UPAENA0 7 26 On UPAENA1 7 26 UPC A Check Digit Off UPACKX0 7 25 On UPACKX1 7 26 UPC A Number System Off UPANSX0 7 26 On UPANSX1 7 26 UPC A 2 Digit Addenda Off UPAAD20 7 26 On UPAAD2...

Page 232: ...9 Off UPEEN00 7 29 On UPEEN01 7 29 UPC E0 Expand Off UPEEXP0 7 29 On UPEEXP1 7 29 UPC E0 Addenda Required Required UPEARQ1 7 30 Not Required UPEARQ0 7 30 UPC E0 Addenda Separator On UPEADS1 7 30 Off UPEADS0 7 30 UPC E0 Check Digit Off UPECKX0 7 30 On UPECKX1 7 30 UPC E0 Number System Off UPENSX0 7 31 On UPENSX1 7 31 UPC E0 Addenda 2 Digit Addenda On UPEAD21 7 31 2 Digit Addenda Off UPEAD20 7 31 5 ...

Page 233: ...enda Required Not Required E13ARQ0 7 33 Required E13ARQ1 7 33 EAN JAN 13 Addenda Separator Off E13ADS0 7 34 On E13ADS1 7 34 ISBN Translate Off E13ISB0 7 34 On E13ISB1 7 34 EAN JAN 8 Default All EAN JAN 8 Settings EA8DFT 7 35 Off EA8ENA0 7 35 On EA8ENA1 7 35 EAN JAN 8 Check Digit Off EA8CKX0 7 35 On EA8CKX1 7 35 EAN JAN 8 Addenda 2 Digit Addenda Off EA8AD20 7 36 2 Digit Addenda On EA8AD21 7 36 5 Di...

Page 234: ...2 7 38 Validate 2 Type 10 Chars and Transmit MSICHK3 7 38 Validate Type 10 then Type 11 Char but Don t Transmit MSICHK4 7 38 Validate Type 10 then Type 11 Char and Transmit MSICHK5 7 38 Disable MSI Check Characters MSICHK6 7 38 MSI Message Length Minimum 4 48 4 MSIMIN 7 38 Maximum 4 48 48 MSIMAX 7 38 GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings RSSDFT 7 39 Off RSSEN...

Page 235: ...74 74 RSEMAX 7 40 Trioptic Code Off TRIENA0 7 41 On TRIENA1 7 41 Codablock A Default All Codablock A Settings CBADFT 7 41 Off CBAENA0 7 41 On CBAENA1 7 41 Codablock A Msg Length Minimum 1 600 1 CBAMIN 7 42 Maximum 1 600 600 CBAMAX 7 42 Codablock F Default All Codablock F Settings CBFDFT 7 43 Off CBFENA0 7 43 On CBFENA1 7 43 Codablock F Msg Length Minimum 1 2048 1 CBFMIN 7 43 Maximum 1 2048 2048 CB...

Page 236: ...gth Minimum 1 366 1 MPDMIN 7 46 Maximum 1 366 366 MPDMAX 7 46 GS1 Composite Codes On COMENA1 7 46 Off COMENA0 7 46 UPC EAN Version On COMUPC1 7 46 Off COMUPC0 7 46 GS1 Composite Codes Msg Length Minimum 1 2435 1 COMMIN 7 47 Maximum 1 2435 2435 COMMAX 7 47 GS1 Emulation GS1 128 Emulation EANEMU1 7 48 GS1 DataBar Emulation EANEMU2 7 48 GS1 Code Expansion Off EANEMU3 7 48 EAN8 to EAN13 Conversion EAN...

Page 237: ...a Matrix Settings IDMDFT 7 51 On IDMENA1 7 51 Off IDMENA0 7 51 Data Matrix Msg Length Minimum 1 3116 1 IDMMIN 7 51 Maximum 1 3116 3116 IDMMAX 7 51 Data Matrix Code Page Data Matrix Code Page 51 IDMDCP 7 52 MaxiCode Default All MaxiCode Settings MAXDFT 7 52 On MAXENA1 7 52 Off MAXENA0 7 52 MaxiCode Msg Length Minimum 1 150 1 MAXMIN 7 52 Maximum 1 150 150 MAXMAX 7 52 Aztec Code Default All Aztec Cod...

Page 238: ... 7833 1 HX_MIN 7 55 Maximum 1 7833 7833 HX_MAX 7 55 Postal Codes 2D 2D Postal Codes Off POSTAL0 7 56 Single 2D Postal Codes Australian Post On POSTAL1 7 56 British Post On POSTAL7 7 56 Canadian Post On POSTAL30 7 56 Intelligent Mail Bar Code On POSTAL10 7 56 Japanese Post On POSTAL3 7 56 KIX Post On POSTAL4 7 56 Planet Code On POSTAL5 7 56 Postal 4i On POSTAL9 7 56 Postnet On POSTAL6 7 57 Postnet ...

Page 239: ... 57 Postal 4i and Postnet with B and B Fields On POSTAL19 7 57 Planet and Postnet On POSTAL12 7 57 Planet and Postnet with B and B Fields On POSTAL18 7 57 Planet and Postal 4i On POSTAL13 7 58 Planet and Intelligent Mail Bar Code On POSTAL15 7 58 Planet Postnet and Postal 4i On POSTAL21 7 58 Planet Postnet and Intelligent Mail Bar Code On POSTAL22 7 58 Planet Postal 4i and Intelligent Mail Bar Cod...

Page 240: ...l 4i Intelligent Mail Bar Code and Postnet On POSTAL28 7 58 Planet Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL29 7 58 Planet Code Check Digit Transmit PLNCKX1 7 59 Don t Transmit PLNCKX0 7 59 Postnet Check Digit Transmit NETCKX1 7 59 Don t Transmit NETCKX0 7 59 Australian Post Interpretation Bar Output AUSINT0 7 60 Numeric N Table AUSINT1 7 60 Alphanumeric C Table...

Page 241: ...CPCMIN 7 61 Maximum 2 80 80 CPCMAX 7 61 Korea Post Default All Korea Post Settings KPCDFT 7 62 Off KPCENA0 7 62 On KPCENA1 7 62 Korea Post Msg Length Minimum 2 80 4 KPCMIN 7 62 Maximum 2 80 48 KPCMAX 7 62 Korea Post Check Digit Transmit Check Digit KPCCHK1 7 62 Don t Transmit Check Digit KPCCHK0 7 62 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 242: ...2 Wait for Trigger On SNPTRG1 8 2 LED State Off SNPLED0 8 2 LED State On SNPLED1 8 2 Exposure 1 7874 microseconds SNPEXP 8 3 Gain None SNPGAN1 8 3 Gain Medium SNPGAN2 8 3 Gain Heavy SNPGAN4 8 3 Gain Maximum SNPGAN8 8 3 Target White Value 0 255 125 SNPWHT 8 4 Delta for Acceptance 0 255 25 SNPDEL 8 4 Update Tries 0 10 6 SNPTRY 8 4 Target Set Point Percentage 1 99 50 SNPPCT 8 4 Selection Setting Indi...

Page 243: ...G IMGFMT6 8 7 File Format KIM IMGFMT0 8 7 File Format TIFF binary IMGFMT1 8 7 File Format TIFF binary group 4 compressed IMGFMT2 8 7 File Format TIFF grayscale IMGFMT3 8 7 File Format Uncompressed binary IMGFMT4 8 7 File Format Uncompressed grayscale IMGFMT5 8 7 File Format BMP IMGFMT8 8 7 Histogram Stretch Off IMGHIS0 8 8 Histogram Stretch On IMGHIS1 8 8 Noise Reduction Off IMGFSP0 8 9 Noise Redu...

Page 244: ... Off IMGGAM0 8 10 Gamma Correction On 0 1000 IMGGAM 8 10 Image Crop Left 0 640 0 IMGWNL 8 10 Image Crop Right 0 640 639 IMGWNR 8 10 Image Crop Top 0 480 0 IMGWNT 8 10 Image Crop Bottom 0 480 479 IMGWNB 8 11 Image Crop Margin 1 238 0 IMGMAR 8 11 Protocol None raw IMGXFR0 8 11 Protocol None default USB IMGXFR2 8 11 Protocol Hmodem Compressed IMGXFR3 8 11 Protocol Hmodem IMGXFR4 8 11 Ship Every Pixel...

Page 245: ...Utilities Add Code I D Prefix to All Symbologies Temporary PRECA2 BK2995 C80 10 1 Show Decoder Revision REV_DR 10 1 Show Scan Driver Revision REV_SD 10 1 Show Software Revision REVINF 10 1 Show Data Format DFMBK3 10 2 Test Menu On TSTMNU1 10 2 Off TSTMNU0 10 2 Application Plug Ins Apps Decoding Apps On PLGDCE1 10 3 Decoding Apps Off PLGDCE0 10 3 Formatting Apps On PLGFOE1 10 3 Formatting Apps Off ...

Page 246: ...11 40 ...

Page 247: ...second for 13 mil UPC Symbol Contrast Grade 1 0 20 or greater Voltage Requirements 4 5 5 VDC at input connector Current Draw 5VDC Scanning Standby 450mA 2 3W 90mA 45W Power Supply Noise Rejection Maximum 100mV peak to peak 10 to 100 kHz Temperature Ranges Operating 32 F to 104 F 0 C to 40 C Storage 4 F to 158 F 20 C to 70 C Humidity 5 to 95 non condensing Mechanical Drop Operational after 30 drops...

Page 248: ...9 mm 435 mm 1 5 17 1 6 7 mil PDF417 36 mm 178 mm 1 4 7 0 10 mil PDF417 36 mm 289 mm 1 4 11 4 10 mil Data Matrix 47 mm 216 mm 1 9 8 5 20 mil Data Matrix 33 mm 414 mm 1 3 16 3 Bar code Standard Range SR 5 mil Code 39 64 mm 145 mm 2 5 5 7 7 5 mil Code 39 59 mm 221 mm 2 3 8 7 10 mil Code 39 42 mm 308 mm 1 7 12 1 20 mil Code 39 64 mm 488 mm 2 5 19 2 13 mil UPC 55 mm 410 mm 2 2 16 1 6 7 mil PDF417 48 mm...

Page 249: ...12 3 Mounting Specifications The 3310 has three M3 x 0 5mm threaded inserts on the bottom of the scanner for mounting with screws ...

Page 250: ...windows and external illumination can easily impact these recommendations If a secondary window is used the window should be mounted as close to the front of scanner as possible at a 90 angle to the optical axis to avoid specular reflections For secondary windows Honeywell recommends the following Optical quality glass 95 transmission in the nominal 650nm wavelength Anti reflective coating on both...

Page 251: ...Use of any cables not provided by the manufacturer may result in damage not covered by your warranty 15 Pin D type 1 PC Data 2 KB Clock 3 KB Data 4 Reserved 5 Reserved 6 Ground 7 Reserved 8 Jump to Pin 11 9 PC Clock 10 Host Power 5V 11 Adapter Power 12 Jump to Pin 10 13 Reserved 14 Reserved 15 Reserved 5 6 11 1 15 10 15 Pin D type 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 Reserved 6 Ground 7 T...

Page 252: ...s not provided by the manufacturer may result in damage not covered by your warranty 15 Pin D type 1 Reserved 2 Reserved 3 Reserved 4 USB D 5 USB D 6 Ground 7 Reserved 8 Reserved 9 Reserved 10 Host Power 5V 11 Jump to Pin 10 12 Reserved 13 Reserved 14 External Trigger 15 External Illumination 5 6 11 1 15 10 ...

Page 253: ...canner s window is not clean If the window is visibly dirty or if the scanner isn t operating well clean the window with one of the cleaning solutions listed below Sani Cloth HB wipes Sani Cloth Plus wipes Super Sani Cloth wipes Isopropyl Alcohol wipes 70 CaviWipes Virex 256 409 Glass and Surface Cleaner Windex Blue Do not submerge the scanner in water The scanner s housing is not watertight Do no...

Page 254: ... cable specify the cable part number of the original interface cable Replacing an Interface Cable 1 Turn the power to the host system OFF 2 Disconnect the scanner s cable from the terminal or computer 3 Rotate the two screws counter clockwise to loosen the screws 4 Gently pull the connector 5 Replace with the new cable Insert the connector into the socket on the 3310 Rotate the two screws clockwis...

Page 255: ...bar code but the data is not displayed correctly on the host screen The scanner may not be programmed for the appropriate terminal interface For example you scan 12345 and the host displays es Reprogram the scanner with the correct Plug and Play bar code See Programming the Interface beginning on page 2 1 The scanner may not be programmed to output your bar code data properly For example you scan ...

Page 256: ...13 4 ...

Page 257: ...oduct Service and Repair Honeywell International Inc provides service for all of its products through service centers throughout the world To obtain warranty or non warranty service please visit www honeywellaidc com and select Support Contact Service and Repair to see your region s instructions on how to obtain a Return Material Authorization number RMA You should do this prior to returning the p...

Page 258: ... OR REPLACEMENT OF THE DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS IN NO EVENT SHALL HII BE LIABLE FOR INDIRECT INCIDENTAL OR CONSE QUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF HII ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CON TRACT WARRANTY TORT OR OTHERWISE EXCEED THE ACTUAL AMOUNT PAID TO HII FOR THE PRODUCT THESE LI...

Page 259: ...g beginning on page 5 1 for information about using Code ID and AIM ID Linear Symbologies AIM Honeywell Symbology ID Possible modifiers m ID Hex All Symbologies 99 Codabar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0 9 A Z a m i 69 EAN Em 0 1 3 4 d ...

Page 260: ... Y 59 Straight 2 of 5 IATA Rm 0 1 3 f 66 Straight 2 of 5 Industrial S0 f 66 MSI Mm 0 1 g 67 Telepen Bm t 74 UPC 0 1 2 3 8 9 A B C UPC A E0 c 63 UPC A with Add On E3 c 63 UPC A with Extended Coupon Code E3 c 63 UPC E E0 E 45 UPC E with Add On E3 E 45 UPC E1 X0 E 45 Add Honeywell Code ID 5C80 Add AIM Code ID 5C81 Add Backslash 5C5C Batch mode quantity 5 35 AIM Honeywell Symbology ID Possible modifie...

Page 261: ... 6 V 56 Codablock F Om 0 1 4 5 6 q 71 Code 49 Tm 0 1 2 4 l 6C Data Matrix dm 0 6 w 77 GS1 em 0 3 GS1 Composite em 0 3 y 79 GS1 DataBar Omnidirectional em y 79 MaxiCode Um 0 3 x 78 PDF417 Lm 0 2 r 72 MicroPDF417 Lm 3 5 R 52 QR Code Qm 0 6 s 73 Micro QR Code Qm s 73 AIM Honeywell Symbology ID Possible modifiers m ID Hex All Symbologies 99 Australian Post X0 A 41 British Post X0 B 42 Canadian Post X0...

Page 262: ... J 4A KIX Netherlands Post X0 K 4B Korea Post X0 3F Planet Code X0 L 4C Postal 4i X0 N 4E Postnet X0 P 50 Non printable ASCII control characters Keyboard Control ASCII CTRL X Mode Control X Mode Off KBDCAS0 Windows Mode Control X Mode On KBDCAS2 DEC HEX Char CTRL X CTRL X function 0 00 NUL Reserved CTRL 1 01 SOH NP Enter CTRL A Select all 2 02 STX Caps Lock CTRL B Bold 3 03 ETX ALT Make CTRL C Cop...

Page 263: ...C4 Back Tab CTRL T 21 15 NAK F12 CTRL U 22 16 SYN F1 CTRL V Paste 23 17 ETB F2 CTRL W 24 18 CAN F3 CTRL X 25 19 EM F4 CTRL Y 26 1A SUB F5 CTRL Z 27 1B ESC F6 CTRL 28 1C FS F7 CTRL 29 1D GS F8 CTRL 30 1E RS F9 CTRL 31 1F US F10 CTRL 127 7F NP Enter Printable Characters DEC HEX Character DEC HEX Character DEC HEX Character 32 20 SPACE 64 40 96 60 33 21 65 41 A 97 61 a 34 22 66 42 B 98 62 b Non print...

Page 264: ... 33 3 83 53 S 115 73 s 52 34 4 84 54 T 116 74 t 53 35 5 85 55 U 117 75 u 54 36 6 86 56 V 118 76 v 55 37 7 87 57 W 119 77 w 56 38 8 88 58 X 120 78 x 57 39 9 89 59 Y 121 79 y 58 3A 90 5A Z 122 7A z 59 3B 91 5B 123 7B 60 3C 92 5C 124 7C 61 3D 93 5D 125 7D 62 3E 94 5E 126 7E 63 3F 95 5F _ 127 7F Extended ASCII Characters DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code 128 80 Ç up arrow 0x48 129...

Page 265: ... 150 96 û F7 0x41 151 97 ù F8 0x42 152 98 ÿ F9 0x43 153 99 Ö F10 0x44 154 9A š Ü F11 0x57 155 9B F12 0x58 156 9C œ Numeric Keypad 0x4E 157 9D Numeric Keypad 0x4A 158 9E ž Numeric Keypad 0x37 159 9F Ÿ ƒ Caps Lock 0x3A 160 A0 á Num Lock 0x45 161 A1 í Left Alt 0x38 162 A2 ó Left Ctrl 0x1D 163 A3 ú Left Shift 0x2A 164 A4 ñ Right Shift 0x36 165 A5 Ñ Print Screen n a 166 A6 ª Tab 0x0F 167 A7 º Shift Tab...

Page 266: ...2 179 B3 180 B4 181 B5 µ 182 B6 183 B7 184 B8 185 B9 186 BA º 187 BB 188 BC 189 BD 190 BE 191 BF 192 C0 À 193 C1 Á 194 C2 Â 195 C3 Ã 196 C4 Ä 197 C5 Å í 198 C6 Æ 199 C7 Ç 200 C8 È 201 C9 É 202 CA Ê 203 CB Ë 204 CC Ì 205 CD Í 206 CE Î 207 CF Ï 208 D0 Ð 209 D1 Ñ 210 D2 Ò Extended ASCII Characters Continued DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code ...

Page 267: ...E1 á ß 226 E2 â Γ 227 E3 ã π 228 E4 ä Σ 229 E5 å σ 230 E6 æ µ 231 E7 ç τ 232 E8 è Φ 233 E9 é Θ 234 EA ê Ω 235 EB ë δ 236 EC ì 237 ED í φ 238 EE î ε 239 EF ï 240 F0 ð 241 F1 ñ 242 F2 ò 243 F3 ó 244 F4 ô 245 F5 õ 246 F6 ö 247 F7 248 F8 ø 249 F9 ù Extended ASCII Characters Continued DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code ...

Page 268: ... 253 FD ý 254 FE þ 255 FF ÿ Code Page Selection Method Country Standard Keyboard Country Honeywell Code Page Option United States standard ASCII ISO IEC 646 IRV n a 1 Automatic National Character Replacement ISO IEC 2022 n a 2 default Binary Code page n a n a 3 Default Automatic National Character replacement will select the below Honeywell Code Page options for Code128 Code 39 and Code 93 United ...

Page 269: ...ed Annex C ISO IEC 646 11 2 82 Ireland ISO IEC 646 207 73 97 Danmark ISO IEC 646 08 8 88 Norway ISO IEC 646 60 9 94 Italy ISO IEC 646 15 5 85 Portugal ISO IEC 646 16 13 92 Spain ISO IEC 646 17 10 90 Spain ISO IEC 646 85 51 91 Code Page Selection Method Country Standard Keyboard Country Honeywell Code Page Option ...

Page 270: ... 28 98 CN 92 99 GB 7 87 FR 3 83 à ç µ é ù è DE 4 84 Ä Ö Ü ä ö ü ß CH 6 86 ù à é ç ê î ô ä ö ü û SE FI 2 82 É Ä Ö Å Ü é ä ö å ü DK 8 88 Æ Ø Å æ ø å NO 9 94 Æ Ø Å æ ø å IE 73 97 Ó É Í Ú Á ó é í ú á IT 5 85 ç é ù à ò è ì PT 13 92 Ã Ç Õ ã ç õ ES 10 90 Ñ ñ ç ES 51 91 Ñ Ç ñ ç COUNTRY Country Keyboard Honeywell CodePage ISO IEC 646 National Character Replacements ...

Page 271: ...54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 67 63 68 69 6A 6C 104 Key U S Style Keyboard 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 4B 50 55 4C 51 56 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1E 2C 1F 20 21 22 23 24 25 26 27 28 29 2B 39 2E 2F 30 31 32 33 34 35 36 37 53 4F 54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 6...

Page 272: ...A 14 ...

Page 273: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 ...

Page 274: ...ataBar 01 00123456789012 PDF417 Postnet Car Registration Zip Code Data Matrix QR Code Test Symbol Numbers Matrix 2 of 5 ID tag UPU 4 State J18CUSA8E6N062315014880T 4 CB 4 State Customer Bar Code 01 234 567094 987654321 01234567891 ...

Page 275: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message ...

Page 276: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...

Page 277: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A C B F E D Save Discard Reset ...

Page 278: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 3310 UG Rev C 9 13 ...

Reviews: