70-6925
39
Application Type:
Pressure Reducing
Connection Size:
Inlet and out air: 1/4 in. NPT (female) Air gage: 1/8
in. NPT (female)
Mounting:
Bracket furnished
Accessories:
305917
2 in. diameter, 1/4 NPT center stem back mount Pressure
Indicating gauge (0 to 160 psi scale) with +/- 3% accuracy
305965
1-1/2 in. diameter, 1/8 NPT center stem back mount Pressure
Indicating gauge (0 to 30 psi scale) with +/- 4% accuracy
804191E
2-1/2 in. diameter, panel-mounted Pneumatic Pressure
Indicating Gauge (0 to 160 psi), 1/8 in. NPT connection, +/-3%
accuracy
Replacement Parts:
14003121-002
Filter for PP902A or B
14004203-001
Filter cartridge kit for PP902C and PP902D.
14004205-002
Filter Station Assembly for PP901, PP902A or B
316134B
PP901A & B Diaphragm Repair Kit
316203A
Pressure Regulator Valve Assembly, PP901A & PP901B,
PP902A,B.
Product Number
Inlet Pressure
Range
Output Pressure Range
Includes
Description
(psi)
(kPa)
(psi)
(kPa)
PP901A1004
45 to
150 psi
310 to
1034 kPa
primary pressure: adj.0
to 25 psi.
primary pressure: adj.0 to
172 kPa.
Gage tapping
to measure
the regulated
pressure.
High Pressure Diaphragm Operated
Reducing Valve with Built-in Adjustable
Relief Valve for Single Pressure Systems.
Includes Mounting Bracket and Gage Taps
But No Gages.
PP901B1002
45 to
150 psi
310 to
1034 kPa
primary pressure: adj.0
to 25 psi; secondary
pressure: adj. 0 to 5 psi
above primary rating
primary pressure: adj.0 to
172 kPa; secondary
pressure: adj. 0 to 34kPa
above primary setting.
Gage tapping
to measure
the regulated
pressure.
High Pressure Diaphragm Operated
Reducing Valve with Built-in Adjustable
Relief Valve for Dual Pressure Systems.
Includes Mounting Bracket and Gage Taps
But No Gages.
PP902C1009
45 to
150 psi
310 to
1034 kPa
primary pressure: adj.0
to 25 psi
primary pressure: adj.0 to
172 kPa.
Sub-micron
filter assembly
and two psig
gages.
Pressure Reducing Valve for Single
Pressure Systems, consists of a PP901A
Valve, a sub-micron filter station, 2 psig
gages, Interconnecting Pipe Fittings, and a
Mounting Bracket
PP902D1007
45 to
150 psi
310 to
1034 kPa
primary pressure: adj.0
to 25 psi; secondary
pressure: adj. 0 to 5 psi
above primary rating
primary pressure: adj.0 to
172 kPa; secondary
pressure: adj. 0 to 34kPa
above primary setting.
Sub-micron
filter assembly
and two psig
gages.
Pressure Reducing Valve for Dual Pressure
Systems, consists of a PP901B Valve, a
sub-micron filter station, 2 psig gages,
Interconnecting Pipe Fittings, and a
Mounting Bracket