UltraKey Touch Installation and User Guide
Document 800-06554 Rev C
55
02/11
2. Press the
Slider_Up/Down
or LCD up/down arrow key to scroll through the options
(standalone settings, serial port, network, language, slider update, cascade linkage,
hardware test, about, and restore default).
3. When you are at the
System Configuration: Serial Port
menu, press
Ent
.
4. Use the
Slider_up/down
to select
Com1(RS485)
. Set Com1 according to the table
below.
5. Press
Slider_Up/Down
keys or LCD up/down arrow key to select
COM1
. Press
Ent
,
the
Serial Setting
menu displays where you can set these COM1 settings: parity,
baud rate, data bit and stop bit.
a. Press LCD up/down arrow key to select
Parity
.
Press
Ent
and use the
Slider_Up/Down
keys to
select
None
,
Odd
, or
Even
. Press
Ent
to save.
b. Press LCD up/down arrow key to select
BaudRate
. Press
Ent
and use
Slider_Up/Down
keys to select
1200
,
1800
,
2400
,
4800
,
9600
,
19200, 38400,
or
57600
. Press
Ent
to save.
c.
Press LCD up/down arrow key to select
DataBit
.
Press
Ent
and use
Slider_Up/Down
to select
7 bit
or
8 bit
. Press
Ent
to save.
d. Press LCD up/down arrow key to select
StopBit
.
Press
Ent
and use
Slider_Up/Down
to select
1 bit
or
2 bit
. Press
Ent
to save.
6. If other changes are required from this menu (language, slider update, cascade
linkage, hardware test, about, restore default), see
. Otherwise the installation and configuration is complete.
7. After finishing keyboard setup, press
Slider_Left
to return to the main menu.
8. To select a camera for control, press a number (1–128) +
Camera
, or
Camera
+
Ent
, or
Ent
.
System Configuration:
Serial Port
Serial Port
Com1(RS485)
Type
RS485
Baud Rate
9600
Parity
None
DataBit
8
StopBit
1
Serial Setting:
Parity
Serial Setting:
Baud Rate
Serial Setting:
Data Bit
Serial Setting:
Stop Bit
Summary of Contents for UltraKey Touch HJC4000
Page 2: ......
Page 3: ...Installation and User Guide ...
Page 8: ...8 Figures ...
Page 10: ...10 Tables ...
Page 64: ...64 Installing UltraKey Touch with PTZ ...
Page 70: ...70 System Administration and Troubleshooting ...
Page 76: ...76 DVR Operation Commands ...
Page 77: ......