Installation and Operating Instructions TRS 33xx
25
immediately after brief offline operation.
To enable this to function smoothly, the external bus controller needs to be equipped with an
accumulator because, otherwise, the controller will not automatically begin with the polling
after a power failure. The software version of the bus controller's EPROM must be at least
release no. ZDICO.01.0V06.04.
The EPROM software version in the connected personnel tableau must be at least release no.
TTABL.00.0V03.00.
If the time recording software has not sent out any tableau LED definitions to the TRS 33xx,
the TRS 33xx uses the following standard settings:
Entry action
red LED
yellow LED
after a correct "Clock in" entry
on
off
after a correct "Clock out" entry
off
off
after a correct "AOB-in" entry
on
off
after a correct "AOB-out" entry
off
on
after a correct "AOB-in" entry with
reason 1 - 128
on
off
after a correct "AOB-out" entry with
reason 1 (for paid holiday)
on
on
after a correct "AOB-out" entry with
reason 2 - 128
on
off
UART (see Ethernet)
6. Suppress reader parameterization:
possible values: Yes/No
In general, the reader settings will be done centrally via the time recording software. In this case, this
parameter must be set to No (factory setting).
The reader parametering via the time recording software can be suppressed (set to Yes), in order to set
the reader settings directly at the terminal. Eventually existing reader settings of the time recording
software will be transmitted indeed, but will be ignored by the terminal.