GB-7
D
GB
F
NL
I
E
▷
In order to end the measurement, briefly press
the selection key again. Measurement stops
once the full number of measuring unit revolu-
tions has been completed.
▷
Measurement is terminated automatically after
5 hours.
▷
A beep indicates that measurement has ended.
Read off the measurement results.
▷
Check test for cyclic test, see page 10 (Check
test).
GPRS modem status
▷
The communication data are displayed.
GPRS modem status
GSM.L : 100%
StCon : GPRS attached
GSM.N : Provider
IPAdr : 192.168.12.1
P.Sta : OK
–
GSM.L: GSM reception level
The reception level between 1 – 31
is transferred to a percentage value
between 3 and 100%.
–
StCon: Connection status
GSM attached: comms module is
switched on
GSM not attached: comms module is
switched off
–
GSM.N: GSM network operator
The name of the current provider is di-
splayed in clear text.
–
IPAdr: IP address is displayed
–
P.Sta: PIN status: OK
PIN status: Failed
▷
For symbols, see page 3 (User keys, selec-
tion key and symbols).
▷
Depending on the GPRS reception level (see
display), the use of an internal or an external
antenna is possible. The internal antenna is the
standard. In order to use an external antenna,
the service cover has to be exchanged by one
with an SMA connector.
Identification & calibration info
Meter-specific technical data are displayed in sub-
menus by pressing the user keys
,
and the
selection key .
ON
OFF
Meter information
Identification &
calibration info
Meter information
Version :1.xx.xx
CRC :0x0000
Details
:REL 120727
Produced :2000
Calibration information
Q1: 0.000m
3
/h CF1:16384
Q2: 6.000m
3
/h CF2:16384
Q3: 12.000m
3
/h CF3:16384
Properties
Volume :2.0dm
3
(S)
Qt :0.60dm
3
/h
DVGW Nr :NG-4701BM0442
Environmental contitions
Electromagnetic :E2
Mechanical :M1
Meter information:
–
Software version
–
CRC: software checksum
–
Software details
–
Year of manufacture
▷
Other screen descriptions (not illustrated):
Calibration information:
–
Meter calibration parameters Q1 to Q3
(adjustment values Q1 to Q3 for three-point
calibration)
Meter characteristics:
–
Cyclic meter volume
–
Transitional flow rate
–
EN 1359 Reg. No.: NG-4701BM0443 (example)
Ambient conditions:
– Electromagnetic
– Mechanical
Firmware traceability
▷
The events shown are saved in the non-volatile
permanent log memory.
▷
The metrology-relevant system events, e.g. firm-
ware upgrades, restarts, low voltage, etc. are
stored in the permanent log memory.
▷
The events in the permanent log have unique
numbers, e.g.:
2 –> Firmware upgrade
15 –> Restart demand
16 –> Restart
▷
Only events which are relevant for the firmware
history are listed in the “Firmware traceability”
sub-menu.
Event: 2
Time: 12:18:45
Date: 12.06.2013
Info: 0xFFFFFFFFFFFF0104
Meter information
1
2
3
4
5
6
Menu description
Event: event that has occurred; can be as-
signed the number 2, 15 or 16
Time: time at which the event occurred
4
Date: date on which the event occurred
5
Info: additional data, as explained below
6
Navigation symbols