GB-5
D
GB
F
NL
I
E
▷
V
b
is the absolute value of the gas meter reading.
▷
In lines F01 to F03, the absolute values of the
tariff registers are displayed.
▷
In the “UES” (UNI-TS 11291 event status) field,
the current diagnostic information is displayed.
▷
All figures are absolute values, which are saved
at the end of the relevant billing period.
▷
The data for the current billing period are up-
dated hourly.
Service mode
Part designations
BK-Gx
DE-07-MI00
2-PTB001
12345
678
Q max
Q min
M07 0102
5
7
8
9
2
1
4
11
10
12
3
6
Electronic index EI3
Display
User keys
4
Opto-adapter interface
5
Service cover
6
Pulse output
7
Communication module
8
Battery for the index
9
Protection clip
0
Battery for the communication module
Installer seal
Connection for external antenna (option)
▷
In Service mode, meter-specific operating data
can be called up.
Activating Service mode
Hold the selection key pressed down.
▷
A pixel will appear in each corner of the display.
Observe one pixel: while the pixel is visible, hold
the selection key pressed down. Release the
key as soon as the pixel has disappeared.
Repeat the process, until all the pixels are off and
“Test instructions” appears in the menu area.
▷
Service mode is activated.
Service mode menu overview
Test instructions
Temperature
Pressure
Conversion
Battery diagnosis
Date and time
LCD pixel test
Cyclic test
Meter information
Main menu
–
–
–
Identification & calibration info
GPRS modem status
Calibration factors
Firmware traceability
Test instructions
Test instructions
Automatic return to main
menu after 5 minutes of
inactivity
Hold on any screen to
return immediately
Temperature
▷
The current gas temperature is displayed.
*Temperature
tg 25.00°C
TC : electronic
tg
:[-25, 55]°C
tsp :20°C
tb :15°C
–
tg currently measured gas temperature
–
TC: type of temperature conversion
Electronic: mathematical conversion to t
b
in index
– t
g
: [ ] max. allowable gas temperature range
t
g
[min. value, max. value]
– t
sp
: specified centre temperature (in accordan-
ce with EN 1359)
– t
b
: base temperature (in accordance with