GB-6
D
GB
F
NL
I
E
▷
Check test for temperature measurement, see
page 10 (Check test).
Pressure
▷
The current pressure data will be displayed.
*Pressure
pg 1013.25mbar
pb :1013.25mbar
PC :electronic
pg :[800.00, 1600.00]mbar
–
pg actual absolute gas pressure inside the
meter
–
PC: electronic – type of pressure conversion
–
pg: [ ] max. allowable gas pressure range p
g
[min.
value, max. value]
–
pb: base pressure (in accordance with
EN 1359)
▷
Check test for pressure measurement, see page
Conversion
▷
The conversion values are displayed.
Conversion
Va 0000000.00m
3
Cf 00.9455660
pg 1013.25mbar
tg 25.00°C
Vb 0000000.00m
3
–
Va volume alarm conditions
–
Cf conversion factor Cf =
(p
g
/ p
b
) x (T
b
/ T
g
) x (Z
b
/ Z)
with Z
b
/ Z = 1
–
pg actual absolute gas pressure inside the
meter
–
tg actual gas temperature
–
Vb volume at base conditions
Battery diagnosis
▷
When the battery is connected, the status “OK”
is shown in the display.
Battery diagnosis
U(battery) 3.60 V
Status : OK
Battery diagnosis
U(hlc) : 3.60 V
U(min) : 3.00 V
Status : Change required
Battery diagnosis
U(hlc) : 3.60 V
U(min) : 3.00 V
Status : Test in progress
Time : 05:00 h:m
Battery diagnosis
U(hlc) : 3.60 V
U(min) : 3.00 V
Status : Removed
Date and time
▷
Information on the date and time display.
*
Date and time
10
–
01
–
2011
10
:
02
:
06
▷
The operator can transfer the switchover be-
tween winter and summer time to the commu-
nication module, provided that it supports this.
▷
The date is given in the format day - month - year.
▷
The date format can differ depending on the
market.
▷
This display is only visible if access to the past
meter readings has been activated.
LCD pixel test
▷
A display test can be carried out in this menu.
Follow the displayed instructions.
▷
A test pattern is shown in the display.
Briefly press the selection key .
▷
A further test pattern appears in the display.
Hold the selection key pressed down. The display
switches to the previous menu.
Cyclic test
▷
The accuracy of the meter can be checked us-
ing a cyclic test.
C 000.00000
m
3
m
3
U 000.00000
tg 25.04°C
N 00000-0 t 00000.00s
*Cyclic test: Starting
Press to abandon test
pg 1023.25mbar
–
C converted volume (temperature and
pressure)
–
U non-converted volume
–
tg gas temperature
–
pg gas pressure (absolute)
–
N number of complete measuring cycles
(measuring unit revolutions) – number of
intermediate sampling points in the measu-
ring cycle (max. 8)
–
t total testing time in seconds
Briefly press the selection key in order to start
the measurement. A beep confirms the start of
the measurement.
▷
The display is visible for the first 5 minutes. It
then disappears but lights up every minute for
10 seconds.