Special functions

Auto Changeover

 (Setup Function 0300): When set to Auto, the thermostat automatically selects 

heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 2 
degrees apart. 

Adaptive Intelligent Recovery

 (Setup Function 0530): Allows the thermostat to “learn” how long 

the furnace and air conditioner take to reach programmed temperature settings, so the temperature is 
reached at the scheduled time.

Compressor Protection

 (Setup Function 0580): Forces the compressor to wait a few minutes before 

restarting, to prevent damage. During this time, the message “Wait” is on the display.

The THP9045 Wiring Module is designed to be used with applicable thermostats in 1 Heat/1 
Cool retrofit applications where only 4 wires are available. The K terminal on the thermostat can 
be used to operate both the fan and compressor on a single wire, and the module is designed to 
receive the signal from the K terminal, split that signal and reroute it to operate the compressor, 
and/or fan for normal operation. See the THP9045 manual for further details.

Optional THP9045 Wiring Module

Temperature Ranges

•  Heat: 40° to 90°F (4.5° to 32°C)
•  Cool: 50° to 99°F (10° to 37°C)

Operating Ambient Temperature

•  0° to 120°F (-18° to 48.9°C)

Shipping Temperature

•  -30° to 150°F (-34° to 66°C)

Operating Relative Humidity

•  5% to 90% (non-condensing)

Physical Dimensions

•  4-23/25” H x 6-2/5” W x 1-19/46” D
•  125 mm H x 166 mm W x 36 mm D

Electrical Ratings

Terminal 

Voltage (50/60Hz) 

Running Current

W

 Heating 

20-30 Vac 

0.02-1.0 A

(Powerpile) 

750 mV DC 

100 mA DC

W2

 Heating 

20-30 Vac 

0.02-0.6 A

Y

 Cooling 

20-30 Vac 

0.02-1.0 A

Y2

 Cooling 

20-30 Vac 

0.02-0.6 A

Aux

 Auxiliary heat 

20-30 Vac 

0.02-1.0 A

O/B

 Changeover 

20-30 Vac 

0.02-0.6 A

E

 Emergency heat 

20-30 Vac 

0.02-1.0 A

L

 Heat pump reset 

20-30 Vac 

0.02-0.6 A

Specifications

Please contact your distributor to order replacement parts.

Cover plate*

 ............................................................ Part Number 32003796-001

*(Use to cover marks left by old thermostats.)

Accessories & replacement parts

Summary of Contents for TH8320ZW1000

Page 1: ...high efficiency furnaces heat pumps steam gravity Heat only including power to open and close zone valves Series 20 and normally open zone valves Heat only with fan Cool only 750 mV heating systems This manual covers the TH8320ZW1000 This thermostat contains a Lithium battery which may contain Perchlorate material Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste p...

Page 2: ...tructions regarding recycling and proper disposal Grasp top and bottom of wallplate and pull to remove from thermostat CAUTION ELECTRICAL HAZARD Can cause electrical shock or equipment damage Disconnect power before beginning installation Drill 3 16 holes for drywall Drill 7 32 holes for plaster Wall anchors Wire hole Mounting screws Must be installed by a trained experienced technician Read these...

Page 3: ...ing during shipment and storage the thermostat is shipped with a plastic tab inserted in the battery holder This tab must be removed dur ing installation Simply pull the plastic tab out of the battery tray Make sure that the battery tray is fully inserted into the ther mostat Push excess wire back into the wall opening Plug wall opening with non flammable insulation Remove factory installed jumper...

Page 4: ...ing system transformer C Common wire from secondary side of cooling system transformer Y 1st stage compressor contactor Y2 2nd stage compressor contactor Aux Auxiliary heat relay G Fan relay E Emergency heat relay L Heat pump reset powered continu ously when System is set to Em Heat system monitor when set to Heat Cool or Off O B Changeover valve for heat pumps K Optional THP9045 Wiring Module Ter...

Page 5: ...r 1 R R Rc joined by jumper W Heat relay G Fan relay C 24VAC common 3 Cool Only System Rc Power 1 R R Rc joined by jumper Y Compressor contactor G Fan relay C 24VAC common 3 K Optional THP9045 Wiring Module Terminal 9 2H 2C System 2 transformers Y2 Cool relay 2 W2 Heat relay 2 Rc Power cooling transformer 1 2 R Power heating transformer 1 2 W Heat relay 1 Y Cool relay 1 G Fan relay C 24VAC common ...

Page 6: ... thermostat with slots in wallplate then push gently until thermostat snaps into place Mount thermostat Set date and time Press st to set time Press st to set date Press st to set month Press st to set year Installer setup Press DONE to save changes Press DONE to save and exit 1 Press SYSTEM 2 Press and hold these two buttons until the display changes 3 Change settings as required see pages 7 9 M3...

Page 7: ...nly 7 2 heat 1 cool heat pump with aux heat 8 2 heat 2 cool multistage conventional 9 2 heat 1 cool multistage conventional 10 1 heat 2 cool multistage conventional 11 2 heat 2 cool heat pump no aux heat 12 3 heat 2 cool heat pump with aux heat 0180 Fan control heating 0 Gas Oil heat equipment controls heating fan 1 Electric furnace thermostat controls heating fan 0190 Changeover valve O B termina...

Page 8: ...ress requires 24VAC connection 0300 Manual Auto changeover 0 Manual changeover Heat Cool Off 1 Automatic changeover Heat Cool Auto Off 0310 Auto changeover deadband 3 Heat cool temperature 3 F apart 1 5 C Other options 2 9 2 F to 9 F 1 C to 5 C 0320 Temperature display 0 Fahrenheit 1 Celsius 0330 Daylight savings 1 Auto change to daylight savings time through 2007 and for areas that do not use the...

Page 9: ... seconds after call for heat ends Other options 30 60 120 0660 Extended fan timer cool 0 Off 90 Fan runs for 90 seconds after call for cooling ends Other options 30 60 120 0670 Keypad lock 0 Keypad unlocked fully functional 1 Partially locked access to temperature settings only 2 Fully locked 0680 Heat temperature control 2 Standard temperature control recommended 1 Choose if room is warmer than s...

Page 10: ...t and fan turn off 1 Heat turns on fan on if Function 0170 is set for heat pump or if Function 0180 is set to 1 2 Second stage heat turns on 4 Emergency heating system 0 Em Heat and fan turn off 1 Em Heat and fan turn on 2 Second stage heat turns on Auxiliary heat System test System status CAUTION EQUIPMENT DAMAGE HAZARD Compressor protection is bypassed during testing To prevent equipment damage ...

Page 11: ...TH8320ZW1000 11 69 2486 03 F M32422 10 Wait 3 To remove the thermostat from the Z Wave network select 0 Z Wave enrollment F M32425 10 DONE 1 F M32424A 10 14 ...

Page 12: ... this return route to access the distant node Enter leave power saving mode When requested from the Z Wave controller the thermostat adjusts its setpoint in order to decrease the power consumption of the HVAC equipment In addition using an Internet gateway enables the person to control the thermostat remotely through the Internet Fan Switch The thermostat can send the message containing the actual...

Page 13: ...the actually supported system switch modes Thermostat Fan State The thermostat can send the message containing the actual state of fan based on fan state change The Fan state can be either Auto or On Thermostat Operating State The thermostat can send the message containing the actual state of the HVAC equipment based on equipment state change The thermostat provides the following operating states ...

Page 14: ...re and the module is designed to receive the signal from the K terminal split that signal and reroute it to operate the compressor and or fan for normal operation See the THP9045 manual for further details Optional THP9045 Wiring Module Temperature Ranges Heat 40 to 90 F 4 5 to 32 C Cool 50 to 99 F 10 to 37 C Operating Ambient Temperature 0 to 120 F 18 to 48 9 C Shipping Temperature 30 to 150 F 34...

Page 15: ...ll not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment ...

Page 16: ... Trademark US Patent No 6 574 581 6 975 958 7 114 554 7 346 467 7 636 604 7 693 582 7 788 936 7 845 576 and other patents pending 2011 Honeywell International Inc 69 2486 03 M S Rev 05 11 Printed in U S A Honeywell Limited Honeywell Limitée 35 Dynamic Drive Toronto Ontario M1V 4Z9 Z Wave is a registered trademark of Zensys Inc and or its subsidiaries ...

Reviews: