INSTALLATION INSTRUCTIONS

69-1414-2

T8611G Chronotherm

®

Deluxe Zoning

Heat Pump Thermostat

APPLICATION

The T8611G Chronotherm® Deluxe Zoning Heat Pump Thermostat provides electronic control of 24 Vac zoned heat 
pump systems. Refer to Table 1 and Table 2 for a general description of the thermostat and zoning applications.

Table 1. Description of T8611 Thermostats.

Table 2. T8611 Zoning Applications.

MERCURY NOTICE

If this control is replacing a control that contains 
mercury in a sealed tube, do not place your old 
control in the trash. Dispose of properly.

Contact your local waste management authority 
for instructions regarding recycling and the 
proper disposal of the old control. 

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow 
the instructions can damage the product or cause 
a hazardous condition.

2.

Check the ratings given in the instructions and on 
the product to make sure the product is suitable for 
your application.

3.

Installer must be a trained, experienced service 
technician.

4.

After completing installation, use these instructions 
to check out the product operation.

Location

Install the thermostat about 1.5m (5 ft) above the floor in 
an area with good air circulation at average temperature. 
See Fig. 1.

Do not install the thermostat where it can be affected by:
— drafts, or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall 

behind the thermostat.

Wallplate Installation

The thermostat can be mounted horizontally on the wall 
or on a 2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box. 
Position wallplate horizontally on the wall or on a 
2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.

1.

Position and level the wallplate (for appearance 
only). The thermostat  functions correctly even 
when not level. 

2.

Use a pencil to mark the mounting holes. 
See Fig. 2.

Model

Power Method

Changeover

System Selection

Fan Selection

T8611G2051

Hardwired

Automatic or manual

Heat-Off-Cool-Auto-Em. Heat

On-Auto

Model

TotalZone

®

EMM-3U

EMM-3

T8611G2051

Yes

Yes

No

Summary of Contents for T8611G Chronotherm

Page 1: ...o make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing installation use these instructions to check out the product operation Location Install the thermostat about 1 5m 5 ft above the floor in an area with good air circulation at average temperature See Fig 1 Do not install the thermostat where it can be affected by ...

Page 2: ...n the wallplate and connect the system wires See Fig 5 IMPORTANT Use 18 gauge color coded thermostat cable for proper wiring 2 Securely tighten each terminal screw 3 Push excess wire back into the hole 4 Plug the hole with nonflammable insulation to pre vent drafts from affecting the thermostat The two OC terminals can be wired to the TZ 4 panel for remote operation of the Zone A Lone feature duri...

Page 3: ...ing thermostat on wallplate NORMALLY WIRE E ON THERMOSTAT TO W1 E ON PANEL ALTERNATIVELY INSTALL JUMPER FROM E TO Y ON THERMOSTAT AND OMIT WIRE TO W1 E ON PANEL CONNECT O B JUMPER ON TZ 4 PANEL WHEN O B TERMINAL ON THERMOSTAT IS CONFIGURED AS O CONNECT THE OC TERMINALS ONLY IF THE ZONE A LONE UNOCCUPIED FEATURE IS DESIRED SEE TZ 4 INSTALLER INSTRUCTIONS FOR EXPLANATION TZ 4 THERMOSTAT CONNECTORS 1...

Page 4: ...ruments like a pen or pencil point can damage the keyboard Temperature Settings Refer to Table 3 for the default program If the daytime energy savings period is not used press the period key Leave or Return until the time is blank See Owner s Guide form number 69 1400 for complete instructions on changing the program NOTE For most applications the thermostat factory settings do not require changin...

Page 5: ... Setup is complete review the settings to confirm that they match the system Period Time Heat Setpoint Cool Setpoint Fan Setting Wake 6 00 AM 70 F 21 C 78 F 25 5 C Auto Leave 8 00AM 62 F 16 5 C 85 F 29 5 C Auto Return 5 00 PM 70 F 20 C 78 F 25 5 C Auto Sleep 10 00 PM 62 F 16 5 C 82 F 28 C Auto M14559 Aux Ht Set Day Time Set Program Mon Wake Leave Return Sleep Outdoor Room Filter Wait System Fan Em...

Page 6: ...reversing valve in heating Deadband 30 3 Heating and cooling setpoints can be set no closer than 3 F 1 5 C 2 thru 10 Heating and cooling setpoints can be set no closer than the chosen value 2 2 F 2 C 4 4 F 2 C 5 5 F 2 5 C 6 6 F 3 C 7 7 F 3 5 C 8 8 F 4 C 9 9 F 4 5 C 10 10 F 5 C Not Used 31 thru 32 Minimum off time for the compressor 33 5 5 minute minimum off time for the compressor 0 thru 4 Minimum...

Page 7: ...F 1 5 C higher than actual room temperature 1 0 5 Display adjusts to 1 F 0 5 C lower than actual room temperature 2 1 0 Display adjusts to 2 F 1 0 C lower than actual room temperature 3 1 5 Display adjusts to 3 F 1 5 C lower than actual room temperature Furnace Air Filter Timer 43 2 30 days System run time 0 1 3 4 0 off 1 10 days 3 60 days 4 120 days Time is counted when heat cool or fan is runnin...

Page 8: ...f days remaining at any time by pressing the i key three or four times If more than one timer is active all active timers show sequentially when pressing the i key several times M14619 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Set Day Time Mon PM M14620 Time Set Program System Fan Ru...

Page 9: ... Fan equipment can be turned on and off 60 0 to 60 19 Keyboard keys test 70 79 Thermostat information including date code and software versions are displayed M14559 Aux Ht Set Day Time Set Program Mon Wake Leave Return Sleep Outdoor Room Filter Wait System Fan Em Heat On Auto Off Cool Auto AM PM Hold for Heat Cool Repl Batt Recovery DST Tue Wed Thu Fri Sat Sun Days Temporary Setting Em Ht M14612 T...

Page 10: ...ain to display the software identification code Example 02 software ID code 2 sy 4 Press the increase key again to display the soft ware revision number Example 001 Revision number 1 5 Press the increase key again to display the EEPROM identification code Example 314 EEPROM ID 314 6 Press the Run Program key to exit the self test The self test times out after four minutes without any key presses C...

Page 11: ... limits are 48 to 99 F 7 to 37 C The setpoint temperature range stops were configured Check Installer Setup numbers 34 and 35 and reconfigure the setpoint stops Heating or cooling does not come on No power to the thermostat Use action listed under Display will not come on Thermostat minimum off time is activated Wait up to five minutes for the system to respond Enter Installer Setup number 33 Reco...

Page 12: ...COOL or AUTO Cooling O G Y Snowflake Symbol Fan Symbol AUTO HEAT or AUTO None B None AUTO HEAT or AUTO Stage 1 Heating B Y Flame Symbol Fan Symbol AUTO HEAT or AUTO Stage 2 Heating B Y W2 Flame Symbol Fan Symbol AUX HEAT AUTO EM HEAT None L EM HEAT AUTO EM HEAT Stage 1 Heating L E Flame Symbol Fan Symbol EM HEAT AUTO EM HEAT Stage 2 Heating L E W2 Flame Symbol Fan Symbol EM HEAT AUX HEAT AUTO AUTO...

Reviews: