MU1H-0635GE51 R1016
50
6.2 Binding radiator controller HR92
1. Insert batteries.
2. Press the
button once: NO BIND should appear on the
display screen.
3. Press the
button for 5 seconds until BIND appears on the
display screen.
4. Press the
button once: BINDING should appear on the
display screen.
5. You should see SUCCESS on the user interface (if not, go back
and reconnect).
6. The name of the assigned room should appear on the HR92 display
when you press the
button.
6.3 Binding room sensor HCF82
1. Press the bind key in the bottom right-hand corner. The red LED
will flash.
2. You should see SUCCESS on the user interface (if not, go back
and reconnect).