Satellite XT R Version
10-6
10.9
Technical Specifications
Power requirements
Voltage
90 ... 240 VAC
Consumption
approx. 22 W / 2.13 A
Physical dimensions
Size:
223 х 97 х 100 mm (W х H х D)
8,8" x 3,8" x 3,9" (W х H х D)
Weight:
1800 g
4 lbs
Housing Protection Class
IP 30
RFI / EMC
EN 50270
EN 61010-1
Operating Conditions
Sample tubing
OD 1/4” ID 3/16”
Response time
< 30 sec. with a tubing length of
10m
Temperature
0 °C ... +40 °C
+32 °F ... +104 °F
Pressure
700 ... 1300 hPа
Humidity
20 ... 90 % r.h.
Note: For applications where the humidity is less than 20 % r.h.,
consider using the MST Sample Conditioning System - Humidifier,
part number 20408-4010.
Minimum Oxygen content of sample
3 %v/v
Part Numbers
Pyrolyzer Module XT NF3
20408-0110
Pyrolyzer Module XT 1,2-DCE
20408-0112
Pyrolyzer Module XT SF6
20408-0114
Pyrolyzer Module XT CH3F
20408-0116
Pyrolyzer Module XT C5F8
20408-0120
Pyrolyzer Module XT C4F6
20408-0122
Warning:
Pyrolyzer Modules 20408-0110, 20408-0112, 20408-0116 and 20408-0122
must only be used with Extractive Module 20404-0200.
Pyrolyzer Modules 20408-0114 and 20408-0120 must only be used with
Extractive Module 20404-0300.
Pyrolyzer Module XT - Section 10