PW6K1ICE Introduction
General UL-Compliance
PW6K1ICE Installation and Configuration Guide
,
Document
800-07985V1, Revision A
3
1.2 General UL-Compliance
A UL-compliant installation requires the following:
• The PW6K1ICE panel must be installed within the protected area.
• The PW6K1ICE is installed for indoor use only.
• The PW6K1ICE must be installed with the provided tamper switch, mounted
to the enclosure cover.
• The fail secure locking mechanism shall only be installed where is is allowed
by the local authority having jurisdiction (AHJ), and it shall not impair the
operation of panic hardware and emergency egress.
Note:
The PW6K1ICE panel is not UL Listed for burglary installations.
1.3 Door Control
One physical barrier can be controlled using single or paired readers.
Two reader ports: Mag, Wiegand, or RS-485 (RS-485 on one reader port capable of
supporting two readers.)
Two supervised inputs, two relays. Diagnostic LEDs.
Dedicated tamper input.
1.4 Access Control
• 15,000 Cardholders, 10,000 Transaction buffer.
• 32 Access Levels per cardholder.
• 19 digit (64-bit) UserId and 15 digit PIN numbers maximum.
• Activation/Deactivation Dates.
• If/Then Macro capability.
1.5 Card Formats
• 8 active card formats per EP1501. PIV-II, CAC, TWIC card compatible.
• Anti-passback support.
• Nested area, hard, soft, or timed forgiveness.