CONNECTIONS 

 

JP1  Alimentazione / Rete 485 

Po12V 

Negative 

485 

(not enable)

 

485 

(not enable)

 

JP2 

Input / Output 

MGP-I input address ccppp02 

MGP-E input address ccppp03 

MGP-I output address ccpp009 

MGP-E output address ccppp010 

JP3 

Lon line / Local line 

Lon 

Lon 

Local Line 

Negative 

JP4 

Direct reader  

DATA 

Brown 

Orange 

CLS 

Red 

Yellow 

CLK 

Orange 

Brown 

+ 5 V 

Yellow 

Red 

Negative 

Green 

Black 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

JP5 

Opposite reader 

DATA 

Brown 

Orange 

CLS 

Red 

Yellow 

CLK 

Orange 

Brown 

+ 5 V 

Yellow 

Red 

Negative 

Green 

Black 

JP6 

USB Programmation 

 

Riserved 

JP7 

Programmation 

 

Riserved 

P1 

Lon Line Configuration 

1-2 

Lon Bus 

2-3 

Lon Free 

Open = No Termination 

P2 

Termination RS 485 

(not enable)

 

(not enable)

 

ST 

Temperature sensor 

 

Analog input – address ccppp04 

T1 

Optical Tamper 

 

Input – Address ccppp01 

 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Notifier TAD-FTT

Page 1: ...nel is missing terminal can manage the controlled passage by itself or together with another terminal MGP outputs and inputs used for actuator local forcing alarm sensor and manual door open command are managed locally Events generated in offline mode are sent to the control panel when connection is established again N B For the central with fw 6 xx are handled only the PIN the first trasponder an...

Page 2: ...ed to programmed mode and internal buzzer emits a long beep If the binding is not accepted the dipslay shows for 3 seconds BINDING FAULT Hear three short beeps and returns to view Digitare Nr PERIPHERAL _ _ _ waiting for peripheral number s insertion DELETE BINDING Normal Forced To put out o service the peripheral binding delete send to command OUT OF SERVICE to specific menu from the other periph...

Page 3: ... recognized are highlighted by a S Press to confirm the configuration Press to return at the normal operation RECEPTION TRANSMISSION FIRMWARE Remove peripheral power Power the peripheral While viewing the Firmware versione press and hold untill you see installer menù Press L3 RECEPTION FIRMWARE if you want to receive the firmware from another peripheral Press L4 TRASMISSION FIRMWARE If you want se...

Page 4: ...ady calibrated on the factory configuration to make a new calibration or to adapt on the installation Remove peripheral power Power the peripheral While viewing the Firmware versione press and hold untill you see installer menù Press L6 SENS TEMP With adjust the teperature press to confirm the configuration Press to return at the normal operation TECHNICAL DATA Power Supply 9 30 Vcc Standby curren...

Page 5: ...al line 1 Lon 2 Lon 3 Local Line 4 Negative JP4 Direct reader 1 DATA Brown Orange 2 CLS Red Yellow 3 CLK Orange Brown 4 5 V Yellow Red 5 Negative Green Black JP5 Opposite reader 1 DATA Brown Orange 2 CLS Red Yellow 3 CLK Orange Brown 4 5 V Yellow Red 5 Negative Green Black JP6 USB Programmation Riserved JP7 Programmation Riserved P1 Lon Line Configuration 1 2 Lon Bus 2 3 Lon Free A Open No Termina...

Page 6: ...l B n 85 Centergross Tel 051 864855 Fax 051 6647638 E mail notifier bologna notifier it 50136 Firenze Via B Telesio 15 Tel 055 69706 Fax 055 556529294 00118 Roma Via Del Casale Santarelli 51 Tel 06 7988021 Fax 06 79880250 E mail notifier roma notifier it 80143 Napoli Palazzo Prof Studi Centro Direzionale Isola E2 Scala B Piano 5 Tel 081 7879398 Fax 081 7879159 E mail notifier napoli notifier it 70...

Reviews: