C - 1
C
Customer Validation Testing
Temperature Test
To insure that the image engine stays within the operating limits of the specification, the following test must be done with the
engine integrated into the designated enclosure.
1. Attach the thermocouple for each engine model as shown below.
2. Configure the scan engine in the desired triggering mode and scan per use case.
Note: Continuous scanning (with no downtime) can produce undesired results.
3. Place the integrated engine into the chamber at the maximum operating temperature (50°C).
4. Record the temperature at various intervals or after the temperature has stabilized.
5. Compare the results with the operating limits.
Note: Testing needs to be performed for each enclosure in which an engine will be used.
Operating Voltage
The operating voltage must be maintained within the engine’s specified limits (see
"Operating Voltage" on page 3-1
Laser Aimer PCB Assembly
Thermocouple
Summary of Contents for N568X
Page 1: ...N568X N569X Decoded Image Engines Integration Manual ...
Page 6: ...iv ...
Page 10: ...viii ...
Page 18: ...1 8 ...
Page 20: ...2 2 ...
Page 30: ...4 2 N56XX Laser Aimer ER lens at 9 27 Window Size Diagram ...
Page 38: ...4 10 ...
Page 50: ...5 12 ...
Page 55: ...A 5 Antenna Polarity Vertical 1GHz 2GHz Range Level dBµV M Frequency Hz Limit ...
Page 63: ...A 13 Antenna Polarity Horizontal 200MHz 1GHz Range Level dBµV M Frequency Hz Limit ...
Page 64: ...A 14 Antenna Polarity Vertical 1GHz 2GHz Range Level dBµV M Frequency Hz Limit ...
Page 65: ...A 15 Antenna Polarity Horizontal 1GHz 2GHz Range Level dBµV M Frequency Hz Limit ...
Page 66: ...A 16 ...
Page 70: ...C 2 LED Aimer PCB Assembly GND Pin 6 V Thermocouple ...
Page 71: ......
Page 72: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com N56XX IM Rev G 12 16 ...