7-101002-00
3
Honeywell Access Systems
LANSRLU1
Overview
The LANSRLU1 (UDS100) Device Server connects serial devices such as Secu-
rity Alarms and Access Control Devices to Ethernet networks using the IP proto-
col family. The UDS100 connects these devices through a TCP data channel or
through a Telnet connection to computers or another Device Server.
The UDS100 uses the Internet Protocol (IP) for network communications and the
Transmission Control Protocol (TCP) to assure that no data is lost or duplicated,
and that everything sent to the connection arrives correctly at the target.
Requirements for WIN-PAK 2.0/Pro R3 and Higher
•
LANSRLU1 at the Remote End
•
N-485-PCI-2L (with 25-pin M-M null modem adapter)
Requirements for WIN-PAK 1.1x
•
UDS100s
at the Local End
at the Remote End
•
485-PCI-2L (with 25-pin M-M null modem adapter)
Troubleshooting Requirements
•
9 pin female to 25-pin male serial cable
•
Network cross-over cable
Pinouts and Connections
LEDs
DB25Serial Port
RJ45 Ethernet Port
Power Plug
13
25
14
1
RTS
in
out
DSR
DCD
DTR in
TX
GND
CTS
RX
*9-30VDC
*+3.3VDC
reg.out
unreg.in
out
out
in
out
DB25 Female DCE Interface RS232
* Optional Power Connection