INTELLIDOX DOCKING MODULE USER MANUAL || TRANSFER DATA FILES
HONEYWELL
PAGE 80 OF 119
Transfer Data Files from the Module
Each module retains detailed, time-stamped data related to compliance test results and
module configuration events. The data are continuously updated, and stored in on-board
memory. When the on-board memory has reached capacity, the newest data replaces the
oldest data.
Each module also stores event logs and datalogs that are transferred from inserted
detectors. When the on-board memory has reached capacity, the newest logs replace the
oldest logs.
You can use Safety Suite Device Configurator software to transfer and manage data files,
or you can transfer the data files to a PC via USB flash drive. Data file transfers may take
several minutes to complete when multiple and/or large data files are transferred. For best
results, Honeywell recommends that you transfer data files periodically.
For more information, refer to the Safety Suite Device Configurator operator manual and
the appropriate detector operator manual.
You can use Safety Suite Device Configurator or Safety Suite to transfer data from
modules that are activated and connected to a network. Data files transferred via Safety
Suite Device Configurator or Safety Suite are added to the database. After the data files
are transferred, you can use Safety Suite Device Configurator or Safety Suite to manage
data and prepare custom reports.
Transferring Data Files via Safety Suite Device Configurator Software
1. Start Safety Suite Device Configurator software, and then log in as an administrator.
2. Select
Import
from the
Devices
menu. The
Import Device Data
window is displayed.
3. Select
IntelliDoX Import.
The
Getting list of IntelliDoXs
message box may be
displayed while Safety Suite Device Configurator prepares a list of available modules.
4. Select one or more modules. Select the file types to import, and then set a date range
for the records. Click
Import
. A downloading progress bar for each selected module
is displayed.
5. When all the progress bars are 100% complete, the
Successfully downloaded logs
dialog box is displayed. Click
OK
to return to Safety Suite Device Configurator.
Transferring Data Files via Safety Suite Device Configurator
1. Open the Safety Suite Device Configurator software, and then log with your
username
and
password
.
2. Click the
Devices
tab.
3. From the ACTIONS column, expand
ACTIONS
and select
Download Data
to
download device’s datalog and event logs.
You can also download the device’s datalog and event by selecting
Device
Details
>
Download Data
.
4. Select
Download Test Data
to download the Test Records from IntelliDoX. A
Downloading data
message is displayed.