Mounting and Connection Instructions IK3 Evaluation Unit BUS-2
65
10.
Start-up
On completion of installation and after switching on the operating voltage, the following must be
programmed in the corresponding functions of the control panel:
The type of switching device, alloction of detector groups, authorization granted, IDENT-KEY
blocking time, possible IDENT-KEY-door release time and door strike functions. For operating units
with I/O and numerical keypad, the number of digits of the keypad code, the keypad code itself and a
hold-up detector group for the hold-up code can also be defined.
The installation mode is then activated at the control panel so that the addresses of the IK3 operating
units can be allocated.
Cover the screw opening with a
VdS seal.
When connecting an IK ope-
rating unit with a numerical
keypad, enter the VdS-approval
number in the column "with
tangible IM" and "with intangible
IM" (see example).
VdS-approval:
4.
Armimg/Disarming
Switching device (SD)
With tangible ID
Profiled cylinder for SD
With in
1)
tangible ID
With time control
1)
Identification characteristic
Quantity
Approval no.
Y
Y
G
M
G
G
G
104030
104030
1
1
11.
Technical data
Rated operating voltage
12 V DC
Operating voltage range
9 V to 15 V DC
Operating voltage U_BDT for one reader
12 V DC,
short circuit-proof,
current-limited at 200 mA max.
Current consumption:
-
EU no-load current
< 15 mA (maximum value)
-
GBS terminated with 12k1
+ 1 mA
-
Relay (Rel1 or REL2)
+ 17 mA
-
Blocking element actuation
via semi-conductor output
+ 1 mA
-
Buzzer
+ 3 mA
-
Outputs - IK2 operating unit
(Buzzer / Disarmed / alarm)
+ 3 mA per output
-
EU, plus all inputs terminated
plus 1 IK3 reader
Type 25 mA
Detector group inputs:
-
Release contact
3.3 V DC DG, monitored at 12k1±40%
-
Glass breakage sensor
12
Housing dimensions (W x H x D)
118 x 118 x 31 mm
Colour
traffic white (similar to RAL 9016)
output
V DC DG, monitored at 12k1±30%
-
Bolt switching contact
12 V DC DG, active LOW
-
Cover contact - external reader
3.3 V DC DG, monitored at 12k1±40%
-
Door strike armature contact
3.3 V DC DG, monitored at 12k1±40%
-
Presence control
12 V DC DG, active LOW
Contact rating of relays
max. 2 A, 30 V AC/DC, 30 VA
Interface to readers
RS-485
Protection category as per EN 60529
IP30
Environmental class as per VdS
II
Operating temperature range
-5 °C to +55 °C