LS10265-000HW-E:D 06/03/2021
22
56052901
–
Rev B
Tamper Switch Installation for UL/ULC Commercial Burglary Applications
For all ULC Commercial Burglary Installations, a Tamper switch must be installed on TG-7 enclosure. The
wiring from Tamper Switch to the panel shall be in a rigid or flexible metal conduit along with other wiring
from TG-7 to the Panel.
REMOTE
ANTENNA
T
R
TELGUARD
Digital TG-7
SIM
1
2
3
4
5
6
7
8
Not Used
Not Used
Power LED
LED Mode
Toggle Button
System Status
LEDs
Alarm Panel
Battery
Conne ctor
Battery wire should
be at le ast ¼ inch
apa rt fr om AC wir es
2
3
4
5
7
G
R
EEN
R
1
T
RE
D
INCOMING
TELCO
RJ31X
TRIP INPUT
BATTERY
TAMPER
SWITCH
8
6
Note
EARTH
GROUND
STC2
(N.C.)
AC
(12V 800MA)
STC1
(N.O.)
1 2 3
5 6
1 2
1 2
1
3
2
4
Battery
Conne ctor
+
-